Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
79 participants
INTERVENTIONAL
2022-02-28
2023-03-15
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Measurement of the Partial Pressure of Oxygen in Cutaneous Tumors Using Electron Paramagnetic Resonance (EPR) Oximetry
NCT03716193
Skin Cancer Diagnostics Using Photoacoustic Imaging
NCT06379581
Optical Coherence Tomography in Patients With Radiotherapy for Head and Neck Cancer
NCT04610645
Low Level Laser Therapy for Radiation Induced Dermatitis in H & N Squamous Cell Carcinoma
NCT02384434
NBTXR3 Activated by Radiation Therapy for the Treatment of Locally Advanced or Borderline-Resectable Pancreatic Cancer
NCT04484909
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Terahertz (1012 Hz) pulsed imaging is a new technique with high resolution and has only emerged recently as a potential new clinical tool for medical imaging. It is a safe imaging modality as the light is non-ionising - it has a million times lower energy than an x-ray and thus doesn't have enough energy to cause ionisation. The power levels used in the THz systems in this study are also very low such that there are no lasting effects. In particular, our in vivo THz imaging systems have a peak power less than 40mW and average power intensity less than 4 µW/cm2. Studies by Hough et al \[2\] have shown that even using peak power 50,000 times higher and an average intensity 30 times higher does not cause any change in gene expression. Therefore, power levels used in our THz in vivo imaging systems are safe and have no known side effects or risks
The SINATRA study will collect preliminary pilot data from participants in a two-arm feasibility observational study.
1. One arm will consist of 100 patients with known or suspected skin cancer (skin cancer defined as: incompletely excised BCC with histologically proven radial margin involvement; biopsy proven BCC, or pigmented lesions suspicious of malignant melanoma). Images will be taken in the clinic prior to planned skin surgery and later compared to the formal histology results after the primary (melanoma) or residual (BCC) tumour has been removed.
2. The second arm will consist of 50 patients with benign dry skin conditions (eczema, psoriasis, skin grafts, scars etc.) and will compare the water content of their skin before and after application of a propriety emollients in common usage (e.g. E45®, Aveeno®, Doublebase®). This will add to the existing dataset that has been recorded from healthy non-patient volunteers (unpublished data, University of Warwick). This may help to guide patient-specific emollient selection in the future.
This will add to the knowledge base to define the appearance of skin cancers under THz skinometry. The spectroscopic findings will not influence the established management that will have been planned in conjunction with a Consultant Dermatologist or Plastic Surgeon and the patient.
Study arm 1: The study arm of 50 patients with benign dry skin conditions will undergo a scan with the THz skinometer and will compare the water content of skin before and after application of propriety emollients in common usage (e.g. E45®, Aveeno®, Doublebase®). Participants will have a THz scan of the dry skin area and a control area. Then they will apply their emollient and wait 10 minutes having another 2 scans of the control area and dry skin area. Finally there will be another 10 minute wait before having a final scan of the control area and dry skin area. There are 6 scans in total for this group.
Study arm 2: The arm with 100 patients with known or suspected skin cancer will have a scan with the THz skinometer in the clinic prior to their planned skin surgery. They will be scanned on the cancerous area and a control area for a total of 2 scans. Later the results of the THz scan will be compared to the formal histology results after the primary (melanoma) or residual (BCC) tumour has been removed.
In vivo THz images from a case study of patients with BCC in 2004 suggested that it should be possible to detect skin cancer hidden beneath the skin using THz imaging. Spectroscopic studies by Emma MacPherson and her colleagues in Cambridge in 2006 showed that the fundamental THz properties of freshly removed (excised) skin cancer tumours are statistically significantly different from healthy tissue and it is thought that the differences are primarily due to changes in water content of the tissue. The high sensitivity of THz light to water also means that the THz signal is strongly attenuated and has a very limited penetration depth in tissue - thus THz scanning would experience great difficulty in detecting deep tumours. The penetration depth depends on the signal-to-noise ratio of the THz imaging system, therefore efforts to improve the signal processing and/or the THz instrumentation have been made. Since then, EM has been investigating the underlying THz image contrast mechanisms as well as developing new algorithms and approaches to improve the accuracy of sample characterisation as well as accelerating THz image data acquisition. This more recent work is pushing the state-of-the-art in THz in vivo imaging, both in accuracy and speed. This, crucially, means the investigators are now better equipped to do THz imaging in vivo studies and the investigators have even been able to account for the pores of skin being blocked (occluded) by the imaging window for the duration of the THz measurement. This 'occlusion' process means the skin cannot breathe normally and water accumulates in the outer most layer of skin, the stratum corneum (SC). EM has exploited this phenomenon to pioneer the use of THz imaging to determine rate of water diffusion within the SC during occlusion. EM has also been developing in vivo imaging instrumentation techniques and identifying the key variables and parameters such as contact pressure and occlusion duration. EM's latest results show that the refractive index of the skin increases both with increasing pressure and increasing occlusion time. These results will be used to develop the THz skinometer and accompanying characterization algorithms, within this study. EM's findings show how THz imaging can be used to measure the hydration profile and water diffusivity of skin and this is the basis of the theory that will be further developed in the SINATRA study to evaluate the penetration and durability of emollients and sunscreens in different skin types. The pilot data collected in the SINATRA trial will be valuable in developing a larger trial leading to a transformative improvement in prevention and treatment of skin cancer and better moisturisation strategies for other skin conditions.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Dry skin condition
2\. The second arm will consist of 50 patients with benign dry skin conditions (eczema, psoriasis, skin grafts, scars etc.) and will compare the water content of their skin before and after application of a propriety emollients in common usage (e.g. E45®, Aveeno®, Doublebase®). This will add to the existing dataset that has been recorded from healthy non-patient volunteers (unpublished data, University of Warwick). This may help to guide patient-specific emollient selection in the future.
Terahertz scanning
Short scans using Terahertz device
Skin cancer
1\. One arm will consist of 100 patients with known or suspected skin cancer (skin cancer defined as: incompletely excised BCC with histologically proven radial margin involvement; biopsy proven BCC, or pigmented lesions suspicious of malignant melanoma). Images will be taken in the clinic prior to planned skin surgery and later compared to the formal histology results after the primary (melanoma) or residual (BCC) tumour has been removed.
Terahertz scanning
Short scans using Terahertz device
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Terahertz scanning
Short scans using Terahertz device
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Diagnosed with dry skin conditions (e.g. eczema, psoriasis, scars etc.)
* Capacity to give informed consent
* Confirmed or suspected skin cancer (incompletely excised BCC with histologically proven radial margin involvement, biopsy proven BCC or pigmented lesions suspicious of malignant melanoma) .
* Diagnosed with an incompletely excised basal cell carcinoma skin cancer (either radial margin involvement on primary excision or following diagnostic punch biopsy).
* Clinically suspicious pigmented skin lesion (suspected melanoma) with a plan for surgical biopsy
* Capacity to give informed consent
Exclusion Criteria
18 Years
100 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Warwick
OTHER
University Hospitals Coventry and Warwickshire NHS Trust
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University Hospital Coventry and Warwickshire NHS Trust
Coventry, West Midlands, United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
JH464519
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.