DIAgnosing GDM usiNg Oral Sugar InStead

NCT ID: NCT05115188

Last Updated: 2025-12-29

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE2

Total Enrollment

31 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-10-01

Study Completion Date

2025-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to compare the positive and negative effects of Dex4® tablets, as an alternative form of fast acting carbohydrate, compared to the current standard diagnostic test, glucose beverage. The investigators hypothesis that because of their availability in solid, chewable form, variety of flavours and lack of carbonation, Dex4® tablets may result in fewer side effects than glucose beverage and provide an equivalent carbohydrate challenge for diagnosis of gestational diabetes.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The project is a prospective randomized crossover study. Women who fall into the screen positive group of the 50g GCT (1 hour serum glucose of 7.8-11.0 mmol/L) will be offered participation in the study. Forty-two participants will be recruited and will be randomly assigned using a pre-populated allocation table to take either the standard OGTT test (75g of glucose beverage) first or the alternative OGTT test (21 Dex4® tablets) first. The first test will be referred to as OGTT-1 and the second test will be referred to as OGTT-2. After completing OGTT-1 at the first test appointment, a questionnaire about side effects from the first test will be completed. After completing OGTT-2 at their second test appointment, a questionnaire about side effects from the second test and test preference will be completed. Each woman will complete both tests within one week and each subject will serve as their own control. Results will be kept blinded in the case report forms until both OGTT tests are done. Serum glucose will be measured using the same internationally standardised glucose-oxidase method (RocheDiagnosis) in the Sunnybrook Biochemistry lab. After serum glucose measurement, all results will be sent to the research team but only the standard of care glucose beverage test data will appear in electronic (or classical) medical records and be used for GDM diagnosis.

The participant population consists of 28 pregnant women between 24-32 weeks' gestation who have screened positive for gestational diabetes on the 50g glucose challenge test. The main drawback to participation is that women will have to undergo two fasting, 1 hour and 2 hour glucose tests within one week. Risks involved with participating in the study include: possibility of pain, bruising, swelling or infection related to drawing blood, allergic reaction symptoms such as itching, facial swelling and anaphylaxis upon consumption if the participant has an allergy to corn based products such as dextrose. These risks will be minimized by screening patients for dextrose allergy before having them sign the informed consent form.

The benefit may not be directly to the patient as they will still need to complete the standard 75g glucose beverage test but they will be contributing to new knowledge on alternatives to the standard test that may benefit other pregnant women, including themselves, in the future.

The ultimate goal of this project is to improve women's health by 1) allowing more women to be screened for GDM and 2) providing an equivalent glucose beverage alternative with fewer side effects, making the screening process more comfortable for patients who cannot tolerate glucose beverage. Improving the tolerability of the test is important because there is growing evidence that GDM significantly increases the risk of short and long term adverse consequences for both the fetus and the mother (10,11). Accurate diagnosis may allow women to implement preventative measures such as a healthy lifestyle, which has shown to be effective in preventing T2DM in women with previous GDM (19,20). There have been recent quality control issues with the commercially available glucose beverage product (16), so this alternative test could become the standard test if the dose calibration is found to be more reliable.

Primary objective 1 (PO-1): to determine if Dex4® tablets is equivalent to glucose beverage for use in the 2-hr 75g OGTT in pregnant women between 24-32 weeks' gestation who have screened positive for GDM.

Secondary objective (SO-1): to determine if women have fewer side effects and prefer the standard (glucose beverage) OGTT test or the alternative (Dex4® tablets) OGTT test

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Diabetes, Gestational

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

It is a population-based, prospective randomized crossover study. Women who fall into the screen positive group of the 50g GCT (1 hour serum glucose of 7.8-11 mmol/L) will be offered participation in the study. 28 Participants will be recruited and will be randomly assigned using a pre-populated allocation table to take either the standard OGTT test (75g of glucose beverage) first or the alternative OGTT test (21 Dex4® tablets) first. The first test will be referred to as OGTT-1 and the second test will be referred to as OGTT-2.
Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

SINGLE

Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

2-hr OGTT with glucose beverage

For the 2 hour oral glucose tolerance test (OGTT), women fast for 8 hours and then consume 75g of glucose beverage, and serum glucose levels are taken at fasting, 1 and 2 hours after drinking the glucose beverage. The 75g OGTT is the gold standard and is performed for GDM diagnosis.

Group Type OTHER

Glucose beverage

Intervention Type DIETARY_SUPPLEMENT

For the 2 hour oral glucose tolerance test (OGTT), women fast for 8 hours and then consume 75g of glucose beverage, and serum glucose levels are taken at fasting, 1 and 2 hours after drinking the glucose beverage. The 75g OGTT is the gold standard and is performed for GDM diagnosis.

2-hr OGTT with Dex4® tablets

Participants will be asked to ingest 21 Dex4® tablets and no more than 300ml of water within 5 minutes. Blood draws will be performed at fasting (before ingesting the dextrose monohydrate tablets), as well as 1 hour after (+/- 15 minutes) and 2 hours (+/- 15 minutes) after ingesting the dextrose monohydrate tablets.

Group Type EXPERIMENTAL

Dex4/ dextrose

Intervention Type DIETARY_SUPPLEMENT

Participants will be asked to ingest 21 Dex4® tablets and no more than 300ml of water within 5 minutes. Blood draws will be performed at fasting (before ingesting the dextrose monohydrate tablets), as well as 1 hour after (+/- 15 minutes) and 2 hours (+/- 15 minutes) after ingesting the dextrose monohydrate tablets.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Dex4/ dextrose

Participants will be asked to ingest 21 Dex4® tablets and no more than 300ml of water within 5 minutes. Blood draws will be performed at fasting (before ingesting the dextrose monohydrate tablets), as well as 1 hour after (+/- 15 minutes) and 2 hours (+/- 15 minutes) after ingesting the dextrose monohydrate tablets.

Intervention Type DIETARY_SUPPLEMENT

Glucose beverage

For the 2 hour oral glucose tolerance test (OGTT), women fast for 8 hours and then consume 75g of glucose beverage, and serum glucose levels are taken at fasting, 1 and 2 hours after drinking the glucose beverage. The 75g OGTT is the gold standard and is performed for GDM diagnosis.

Intervention Type DIETARY_SUPPLEMENT

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Positive 50g GCT result between 7.8-11.0 mmol/L
* Female
* Singleton pregnancy
* Informed consent obtained and signed

Exclusion Criteria

* Use of steroids, terbutaline, or metformin within the last 4 weeks
* Previous diagnosis of diabetes type 1 or 2 outside of pregnancy or diagnosis with any form of diabetes prior to 20 weeks of pregnancy
* Allergy to any ingredients (including the non-medicinal ingredients) in Dex4® tablets or Glucodex solution
Eligible Sex

FEMALE

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Sunnybrook Health Sciences Centre

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Sunnybrook Health Sciences Centre

Toronto, Ontario, Canada

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Canada

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol

View Document

Document Type: Informed Consent Form

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

REB 418-2018

Identifier Type: -

Identifier Source: org_study_id