Design and Rationale of the Assessment of the MindMics Recording System

NCT ID: NCT05103579

Last Updated: 2021-11-02

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

29 participants

Study Classification

OBSERVATIONAL

Study Start Date

2020-03-24

Study Completion Date

2021-01-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

MindMics earbuds is a new technology designed enhance an individual's quality of life by continuously monitoring the heart rate, stress, and blood pressure allowing patients to make decisions regarding their health. MindMics has a working prototype of the ear buds which will perform all the conventional tasks of earbuds (listen to music, etc.), but, in addition, will measure heart rate, stress, blood pressure. The earbuds capture the sounds made by the various cardiac structures pulsing and moving blood. The sound is caused by the acceleration and deceleration of blood and the turbulence developed during rapid blood flow.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Introduction:

This study will evaluate the efficacy of the MindMics earbud recording apparatus to record data from patients with known atrial fibrillation as well as those in sinus rhythm. Patients in the clinic and patients with atrial fibrillation scheduled to undergo elective direct-current cardioversion will be the chosen subjects. This process will select a variety of patients to allow evaluation of the Mindmics apparatus's ability to collect data from patients with normal as well as abnormal cardiac rhythms.

Hypotheses

The MindMics earbud device is capable of recording normal cardiac rhythms in patients noninvasively using earbud device in a noninvasive manner. The same apparatus may be capable of discerning atrial fibrillation compared with normal sinus rhythm. This will be evaluated by collecting information from patients with atrial fibrillation in the office as well as those scheduled to undergo an elective direct-current cardioversion procedure. A timed recording of the clinical rhythm while wearing the apparatus will allow simultaneous recording of data from an ECG recording (documenting the patient's clinical arrhythmia) at the same time the MindMics earbud records its data obtained during the ECG recording of the patient's rhythm. For those patient scheduled for direct current cardioversion, the patient will undergo the direct-current cardioversion and a second recording will be obtained during sinus rhythm afterwards allowing an appropriate comparison of the differences in the recording sets.

The objective is to demonstrate differences between recordings made in atrial fibrillation and those in sinus rhythm that can be used to develop an algorithm allow discernment between atrial fibrillation and sinus rhythm.

OVERALL DESIGN

This study is designed to collect sequential patient's in a nonrandomized unblinded procedure designed to collect information using the apparatus to document its capability of recording cardiac rhythm data, then using this recorded data to determine whether the patient has an abnormal cardiac rhythm. Initial efforts will be directed to develop an algorithm to detect atrial fibrillation.

Patients will be recruited from inpatients at Palmetto Tuomey Medical center or in the outpatient office during routine office visits for patients with clinical arrhythmias for elective recording for group 1. Group 2 patients will be recruited prior to direct-current cardioversion. Both groups will be explained the study, what is their participation, potential risk and expectations for their participation in the study.

Once selected each patient will be required to sign a study protocol consent form before actual entry into the study. Once the consent is completed, the patients will be connected to the Mindmics apparatus as well as an electrocardiographic recording system. The study participant will lie quietly collecting simultaneous electrocardiographic data and data from the Mindmics earbuds. Group 1 patients will be identified as outpatients during their routine office visits will have 15 minutes of recording in a patient examination room during the office visit. Group 2 patients undergoing Direct-Current Cardioversion will have 15 minutes of recording prior to the cardioversion procedure and 15 minutes of recording after completion of the cardioversion procedure.

NUMBER OF PARTICIPANTS

Approximately 25 patients will be recruited for group 1 from inpatient or outpatient office visits. These patients will have persistent atrial fibrillation during the office visit. If necessary would consider increasing the total number of patients to 50 in this group Approximately 25 patients will be recruited for group 2 prior to direct-current cardioversion allowing collection of data from before and after cardioversion to document differences in recordings during sinus rhythm after having successful cardioversion from atrial fibrillation. While certainly some patients will revert back to atrial fibrillation and not have periods of sinus rhythm is anticipated the vast majority of patients will have successful cardioversions long enough to record at least the 15 minutes post cardioversion in sinus rhythm. If necessary would consider increasing the total number of patients to 50 in this group

DURATION The total duration of involvement for each study participant is for the duration of the recording interval. Group 1 participants will have a 15-minute recording interval while those in group to will have 2 sessions of 15 minutes each separated by the direct current cardioversion. No further participation will be required.

All data collected during the study will be kept by Mindmics. All data collected in the study will be de-identified

OUTCOME MEASURES and STATISTICAL ANALYSIS

Each recording will be evaluated by Mindmics to evaluate the ability of the recording apparatus to provide data that would lead to clear discernment of the patient's cardiac rhythm as well as rate related phenomena. At this juncture, it is anticipated the collected data will be used to develop and test algorithms yet to be developed and to make clinical determinations of the cardiac rhythms.

Initial data will be evaluated to determine if the Mindmics earbuds are capable of discriminating atrial fibrillation from normal sinus rhythm. For that reason, it is not possible to suggest a statistical method until it is determined the device data can be used to evaluate differences in cardiac rhythm.

SAFETY

There is no potential harm or injury associated with the research. The probability and magnitude of harm or discomfort anticipated in the research are not greater than those ordinarily encountered in daily life or during the performance of routine physical or psychological examinations or tests. There are no potential risks with respect to psychological, sociological, economic, or legal. The overall risk of the device in minimum.

Potential Benefit to Participants This study is performed in such a manner that it is not anticipated there would be an ability to provide diagnostic data that may be helpful for the study participants.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Atrial Fibrillation Arrythmia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

CROSS_SECTIONAL

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Patients with AFib

Patients with AFib

MindMics

Intervention Type DEVICE

Patients rhythms was recorded using MindMics device

Normal patients

Normal patients without AFib

MindMics

Intervention Type DEVICE

Patients rhythms was recorded using MindMics device

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

MindMics

Patients rhythms was recorded using MindMics device

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* AFib

Exclusion Criteria

* N/A
Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

MindMics Inc

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Prisma Health

Sumter, South Carolina, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Pro00096535

Identifier Type: -

Identifier Source: org_study_id