Pre TAVI Membranous Septum Measurement Predicts High Grade Iatrioventricular Conduction Disorders in Patients With Specific Pacemaker Implanted After TAVI. The STIM TAVI-MS Study

NCT ID: NCT04906837

Last Updated: 2021-05-28

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

197 participants

Study Classification

OBSERVATIONAL

Study Start Date

2020-06-20

Study Completion Date

2021-02-26

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Conduction disturbances are a major complication of TAVI. There is no predictor of post-TAVI conduction disorder. The study of the membranous septum on the pre-TAVI scanner and the valve implantation height are promising and little studied data on the occurrence of post-TAVI conduction disorders.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

After being developed for the treatment of aortic stenosis in inoperable patients, trans aortic valve implantation (TAVI) techniques and devices have gradually improved, and its use can now be considered in low-risk populations. . However, the need for pacemaker implantation after TAVI remains one of the most common complications, and this issue needs to be addressed before further expanding the TAVI indications.

Implantation of PM after TAVI is associated with increased morbidity and mortality, and there are no formal predictors of these conduction disturbances. Some studies suggest that the existence of preoperative conduction disturbances (eg, right bundle branch block or 1st degree AVB) are associated with greater PM implantation or greater reliance on ventricular pacing.

Other studies have focused on anatomical measurements such as the height of the membranous septum obtained on the pre TAVI scanner, calcifications of the aortic ring and the depth of the valve implantation obtained on the angiography of the TAVI procedure. . The depth of valve implantation in relation to the height of the membranous septum would be a predictor of conduction disorders and PM implantation post TAVI.

Anatomically, the left branch of the bundle of HIS originates approximately 6 mm below the aortic annulus. Implantation of TAVI can affect the conduction tissues and lead to conduction abnormalities where the penetrating portion of the HIS emerges on the surface of the LV flushing chamber. The farther away the emerging part of the HIS is from the ring, the less likely it is that an implant will encroach on it, and impair conduction.

Because the emerging part of the bundle of His is "sandwiched" between the membranous septum and the posterior crest of the muscular septum, the lower end of the membranous septum provides an anatomical landmark for the left ventricular exit point of the bundle of His, with the length of the membranous septum equivalent to the distance aortic ring - bundle of HIS.

The STIM TAVI study showed that 30% of patients implanted with a post-TAVI pacemaker did not have high-grade AVB beyond 7 days post-implantation. Patients with early AVB (D1-D7) were at high risk of developing late AVB. The study did not identify a population at low risk of late-onset AVB, nor any pre-TAVI clinical or paraclinical criteria predictive of post-TAVI AVB.

The study of the anatomy of the membranous septum and the height of implantation of the aortic prosthesis in the STIM TAVI population would make it possible to analyze new predictive criteria for late AVB (after D7).

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Conduction Disturbance Trans Aortic Valve Implantation (TAVI)

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

membranous septum valve implantation height predictive factors

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

RETROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Trans aortic valve implantation

Measurement of the membranous septum on the pre TAVI scanner and the valve implantation height

Intervention Type DIAGNOSTIC_TEST

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* 18 years old
* Patients included in the STIM TAVI study with full follow-up (not excluded from STIM TAVI for lack of data)
* Patients who did not object to the use of CT and angiography data

Exclusion Criteria

* Oral opposition to participate
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Association de Recherche en Cardiologie des Alpes

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

CH Annecy Genevois

Annecy, , France

Site Status

Countries

Review the countries where the study has at least one active or historical site.

France

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

AlpinARC

Identifier Type: -

Identifier Source: org_study_id