Safety and Effectiveness Study of Dragonfly System for Degenerative Mitral Regurgitation
NCT ID: NCT04734756
Last Updated: 2021-06-11
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
ENROLLING_BY_INVITATION
NA
120 participants
INTERVENTIONAL
2021-05-04
2027-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Safety and Effectiveness Study of Dragonfly System for Functional Mitral Regurgitation
NCT04733404
Randomized Controlled Study of Dragonfly System for Functional Mitral Regurgitation
NCT07243158
Dragonfly-M Early Feasibility Study
NCT04528576
DragonFly EU Pivotal Study
NCT05927441
A Feasibility Study of the Millipede Transcatheter Annuloplasty Ring System in Patients With Functional Mitral Regurgitation
NCT04147884
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Treatment success at 12 months is used as the primary endpoint, with the definition as freedom from death, valve dysfunction surgery, and moderately severe or severe mitral regurgitation (MR \>2+) at 12 months.
The secondary endpoints include acute procedural success, acute device success, and surgery for valve dysfunction, NYHA class I or II at 30 days, 6 months, and 12 months, and the improvement in the quality of life change from baseline as assessed by the Kansas City Cardiomyopathy Questionnaire (KCCQ) score at 12 months after the procedure. The safety endpoints include major adverse events (MAEs), all-cause mortality, and cardiac mortality at 30 days, 6 months, and 12 months after the procedure.
To evaluate the safety and effectiveness of the Valgen Medtech DragonFly Transcatheter Mitral Valve Repair System in the treatment of patients with clinically significant chronic moderate (3+) or severe (4+) degenerative mitral regurgitation (DMR) who have been evaluated by the local heart team as being at high surgical risk, and to evaluate the product performance.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Dragonfly Mitral Valve Repair System
The experimental group is allocated to use a novel mitral valve repair system for edge-to-edge repair manufactured by Hangzhou Valgen Medtech Co., Ltd.
Dragonfly Transcatheter Mitral Valve Repair System
To conduct edge-to-edge repair with Dragonfly System under the guidance of transesophageal echocardiography.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Dragonfly Transcatheter Mitral Valve Repair System
To conduct edge-to-edge repair with Dragonfly System under the guidance of transesophageal echocardiography.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Symptomatic moderate-to-severe (3+) or severe (4+) mitral valve regurgitation (DMR) confirmed by transthoracic echocardiography.
3. NYHA functional class II, III, IV.
4. Left ventricular ejection fraction (LVEF) ≥ 20%.
5. Anatomically suitable for transcatheter mitral valve repair by edge-to-edge technique, and can be treated by the DragonflyTM device, as assessed by the site investigators and confirmed by the echo core laboratory and eligibility committee.
6. High surgical risk as defined by either Society for Thoracic Surgery Risk Calculator score for valve replacement ≥ 8 points; or STS score for valve repair ≥ 6 points; or other high surgical risks. e.g. presence of ≥2 moderate to severe frailty factors; or the presence of possible surgical obstacles; or the presence of ≥2 major organ dysfunctions that could not be improved after surgery; or other surgical high-risk factors as determined by the local heart team.
7. Transseptal catheterization and femoral vein access is determined to be feasible.
8. The subject or subject's legal representative has been informed of the nature of the trial, willing to accept the experimental tests, and has provided written informed consent.
Exclusion Criteria
2. The presence of other severe heart valve disease requiring surgical intervention.
3. Prior mitral valve leaflet surgery or transcatheter mitral valve intervention.
4. Estimated pulmonary artery systolic pressure (PASP) \> 70 mm Hg assessed by echocardiography.
5. History of acute myocardial infarction in the prior 4 weeks or untreated clinically significant coronary artery disease requiring revascularization.
6. Any percutaneous cardiac intervention within the 30 days, or any cardiac surgery within the 6 months prior to randomization; or if, in the judgment of the investigator, the subject's femoral vein is unable to accommodate a 25F catheter or has an ipsilateral deep venous thrombosis; or the anatomy is not accessible for transseptal puncture.
7. Subjects in whom transesophageal echocardiography (TEE) or general anesthesia is contraindicated.
8. End-stage heart failure (ACC/AHA stage D), or prior orthotopic heart transplantation, or on the waiting list for a heart transplantation.
9. Active endocarditis, or active rheumatic heart disease, or leaflets degenerated from either endocarditis or rheumatic disease.
10. Cerebrovascular accident within 30 days prior to randomization or symptomatic severe carotid stenosis (\> 70% by ultrasound).
11. Evidence of acute peptic ulcer or gastrointestinal hemorrhage in the prior 3 months.
12. Hemorrhagic or coagulopathic disorders, contraindications to antithrombotic medication.
13. Modified Rankin Scale ≥4.
14. The subjects suffer from diseases which may lead difficulty in evaluating treatment (e.g., cancer, severe metabolic disease, psychosis, etc.);
15. Pregnant or breastfeeding women.
16. Hemodynamic instability defined as systolic pressure \< 90 mmHg without afterload reduction, cardiogenic shock, or the need for inotropic support or an intra-aortic balloon pump.
17. Active infections requiring antibiotic therapy (in the case of temporary illness, antibiotics must be discontinued for at least 14 days before the subject can be enrolled).
18. Currently participating in an investigational drug or another device study that has not completed its primary endpoints or would clinically interfere with the endpoint of this study. Note: Trials requiring extended follow-up for products that were investigational, but have since become commercially available, are not considered investigational trials.
19. In the judgment of the investigator, subjects may not complete the trial according to poor compliance or in other circumstances when the investigator determines that the subject is unfit to participate in the study.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Hangzhou Valgen Medtech Co., Ltd
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Jianan Wang
Role: PRINCIPAL_INVESTIGATOR
Second Affiliated Hospital, School of Medicine, Zhejiang University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
The Second Affiliated Hospital Zhejiang University School of Medicine
Hangzhou, Zhejiang, China
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Wang J, Liu X, Pu Z, Chen M, Fang Z, Jin J, Dong J, Guo Y, Cheng B, Xiu J, Luo J, Tang Y, Wang Y, Chen X, Zhang G, Shao Y, Song G, Hong L, Jiang H, Wu Y, Yuan Y, Chen L, He B, Wang J, Xu K, Yang Y, Zhou D, Zhang Q, Li Y, Ma K, Lam YY, Han Y, Ge J, Lim DS, Pivotal Trial Investigators FTD. Safety and efficacy of the DragonFly system for transcatheter valve repair of degenerative mitral regurgitation: one-year results of the DRAGONFLY-DMR trial. EuroIntervention. 2024 Feb 19;20(4):e239-e249. doi: 10.4244/EIJ-D-23-00361.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
DragonFly-01
Identifier Type: -
Identifier Source: org_study_id