Postoperative Total Wavefront Pattern Between Two Types of Intraocular Lenses Implanted in Cataract Surgery
NCT ID: NCT04701255
Last Updated: 2021-01-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
40 participants
INTERVENTIONAL
2020-11-09
2021-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
In the human phakic eye, the shape of the normal cornea induces average positive spherical aberration and remains unchanged over time, whereas the crystalline lens has a negative spherical aberration. As a result, overall spherical aberration in the young eye is low.
However, the compensation slowly decreases with the aging lens and is fully lost after cataract extraction and implantation of a standard intraocular lens.
Optical studies showed that conventional biconvex spherical intraocular lenses add their intrinsic positive spherical aberration to the positive spherical aberration of the cornea resulting in image imperfection and blur. As a useful side effect, this also increases the depth of focus -often referred to as pseudo-accommodation.
New Aspheric intraocular lenses designs currently in use impart negative spherical aberration, about 0.17 to 0.20 microns of negative spherical aberration. This added negative spherical aberration partially corrects the average amount of corneal positive spherical aberration \& compensate for its effect. Our study will include (FocusForce foldable aspheric intraocular lens, Bausch \& Lomb, New Jersey, USA) as an example of this type of negative spherical aberration intraocular lenses.
In order to improve retinal image quality without compromising depth of field, or introducing other aberrations, aberration-free aspheric intraocular lenses were developed with no inherent spherical aberration.
The other intraocular lens targeted in our study (Akreos AO Microincision lens, Bausch \& Lomb, New Jersey, USA) is an example of this type of IOLs.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of Intraocular Lens Power Calculation Methods After Corneal Laser Refractive Surgery in Axial and Refractive Ammertropia
NCT01979172
Corneal High Order Aberrations After Stream Light and Mechanical Photorefractive Keratectomy
NCT06110286
Spherical Aberration and Contrast Sensitivity in IOLs
NCT00576485
Wavefront Analisys and Contrast Sensitivity of Spherical and Aspherical Intraocular Lenses
NCT00347243
Correlations Between Lens Star and Phacoemulsification.
NCT05290896
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
On the other hand, Wave front analysis of the ocular optical system has increased our knowledge of the aberrations in the eye. The importance of measuring optical aberrations lies not only in the presence of natural aberrations in the human eye, but also in its usefulness for evaluating individual surgical outcomes. By using Zernike polynomials, the aberrations of the ocular system can be characterized. Zernike coefficients of the higher-order aberrations can be derived from corneal topographic data. And for those generated by the whole optical system of the eye can be derived from aberrometry.
With current small-incision cataract surgery, it has been reported that the average postoperative corneal topography does not differ significantly from average preoperative corneal topography, so in our study we will focus on the ocular \& internal wave front changes.
With the high resolution pyramid wavefront sensor incorporated in (SCHWIND PERAMISĀ®, topography and Aberrometry, Kleinostheim, Germany) we will evaluate and compare the total ocular wave front and the corneal wave front in our study to identify and estimate the internal aberrations . This new sensor uses an extended source instead of a point-like source avoiding in this manner the oscillation of the pyramid.
SCHWIND PERAMIS evaluates the ocular wave front aberrations with 45,000 measuring points - without any overlap and with clear assignment of each point \& records 33 images per second and automatically selects the image with the best measurement. Together with real-time measurement, this ensures a new level of detail resolution and precision. SCHWIND PERAMIS can also be used to compare a patient's corneal and ocular wave front data. The direct comparison provides information about whether a visual defect is located on the surface of the cornea or within the eye itself, thus allowing us to identify and evaluate internal aberrations.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
aberration-free IOL
20 human eyes with aberration-free intraocular lens Implantation after phacoemulsification cataract surgery
phacoemulsification with intraocular lens implantation
treatment of cataract by phacoemulsification procedure and implantation of different types of IOLs.
ocular aberrometer assesment
evaluate total ocular wavefront, corneal wavefront \& internal wavefront (High order aberrations ) post operative by corneal tomography and aberrometer
negative spherical aberration IOL
20 human eyes with negative spherical aberration intraocular lens Implantation after phacoemulsification cataract surgery
phacoemulsification with intraocular lens implantation
treatment of cataract by phacoemulsification procedure and implantation of different types of IOLs.
ocular aberrometer assesment
evaluate total ocular wavefront, corneal wavefront \& internal wavefront (High order aberrations ) post operative by corneal tomography and aberrometer
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
phacoemulsification with intraocular lens implantation
treatment of cataract by phacoemulsification procedure and implantation of different types of IOLs.
ocular aberrometer assesment
evaluate total ocular wavefront, corneal wavefront \& internal wavefront (High order aberrations ) post operative by corneal tomography and aberrometer
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
2. Persistent Corneal edema (epithelial or stromal).
3. Co-existing corneal pathology.
4. Ocular surface disease \& Dry eye syndrome.
5. Posterior capsular opacity .
6. Anterior capsular contraction (phimosis).
7. Ocular inflammation.
8. Co-existing Vitreoretinal diseases.
21 Years
75 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Cairo University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Aya Ghonaim
resident of ophthalmology
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Aya G Ibrahim, MBBCh
Role: PRINCIPAL_INVESTIGATOR
Dar El Oyoun ophthalmology hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
facultyof medicine, Cairo university
Cairo, , Egypt
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
336-2020
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.