Measuring Thickness of the Normal Diaphragm in Children Via Ultrasound.

NCT ID: NCT04589910

Last Updated: 2022-08-12

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

120 participants

Study Classification

INTERVENTIONAL

Study Start Date

2020-09-01

Study Completion Date

2021-08-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Critically ill children treated with invasive mechanical ventilation (iMV) in a paediatric intensive care unit (PICU) may suffer from complications leading to prolonged duration of ventilation and PICU stay. Prolonged ventilation is associated with haemodynamic dysfunction, neuromuscular insufficiency, malnutrition, metabolic disorders and diaphragmatic muscle weakness. Evidence from adult critical care supports the existence of ventilator induced diaphragmatic dysfunction, defined as a iMV-induced loss of diaphragmatic force - generating capacity - characterised by muscle fibre atrophy, myofibril necrosis and disorganization.

Diaphragm function or contractility can be assessed by measuring the diaphragm thickening during inspiration and expiration with ultrasound and is expressed as a thickening fraction (TF).

A low diaphragm contractile activity in adults has been associated with rapid decreases in diaphragm thickness, whereas high contractile activity has been associated with increases in diaphragm thickness. Contractile activity decreased with increasing ventilator driving pressure and controlled ventilator mode. Maximal thickening fraction (a measure of diaphragm function) was lower in patients with decreased as well as increased diaphragm thickness than in patients with unchanged thickness (p=0.05). Titrating ventilatory support to maintain normal levels of inspiratory effort may prevent changes in diaphragm configuration associated with iMV, but more research is needed to confirm this supposition.

Only one study has shown the presence of diaphragm atrophy in critically ill children on iMV for acute respiratory failure. The diaphragm contractility, measured as thickening fraction, was strongly correlated with a spontaneous breathing fraction.

Norm data for diaphragmatic thickness and TF in children are only available for healthy neonates (n=15) and children (n=48) from 8 till 20 years of age.

The purpose of this study is to determine values of normal diaphragm thickness and TF in children aged 0-8 years by ultrasound. This age range reflects the largest patient group treated in the PICU.

Once these values are known, the clinical relevance of the measuring of the diaphragm thickness of ventilated children by ultrasound can be further studied.

Objective of the study:

Primary objective: To determine diaphragm thickness and thickening fraction in healthy children below or equal to 8 years of age.

Secondary objective: To determine the interrater reliability of operators performing the ultra-sound

Study design:

prospective, cohort study.

Study population:

Healthy children in four age groups: 0-6 months; 6 months-1 year; 2-4 years; and 5-8 years.

Participants will be recruited in two ways:

Group 1. Parents of children scheduled to undergo a daycare procedure will asked permission for their child to join the study. These children undergo a minor procedure and are assumed to have a normal diaphragm; therefore are considered 'healthy''.

Group 2. Health professionals working on the PICU or other departments of Erasmus MC-Sophia as well as family, friends and neighbours of members of the research group will be asked to recruit 'healthy' children. The investigators will recruit participants by means of brochures in which children and/or caregivers are invited to contact the researchers when interested to participate in this study.

Primary study parameters/outcome of the study:

To determine diaphragm thickness and thickening fraction in healthy children below or equal to 8 years of age.

Secondary study parameters/outcome of the study (if applicable):

To determine the interrater reliability of operators performing the ultra-sound

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Mechanical Ventilation Complication Pediatric ALL Intensive Care Unit Acquired Weakness

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

SCREENING

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Ultra-sound arm

Ultrasound measurement of the diaphragm will be performed with the use of a Sono Site SII, portable system in B mode with the child in a 30-degree supine position. The diaphragm thickness will be measured with a high frequency (4-10 MHz) linear array transducer placed in the ninth or tenth intercostal space between the anterior and midaxillary lines in the zone of apposition between lung and liver.

Group Type OTHER

diaphragm thickness and thickening fraction

Intervention Type DIAGNOSTIC_TEST

Ultrasound measurement of the diaphragm will be performed with the use of a Sono Site SII, portable system in B mode with the child in a 30-degree supine position. The diaphragm thickness will be measured with a high frequency (4-10 MHz) linear array transducer placed in the ninth or tenth intercostal space between the anterior and midaxillary lines in the zone of apposition between lung and liver.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

diaphragm thickness and thickening fraction

Ultrasound measurement of the diaphragm will be performed with the use of a Sono Site SII, portable system in B mode with the child in a 30-degree supine position. The diaphragm thickness will be measured with a high frequency (4-10 MHz) linear array transducer placed in the ninth or tenth intercostal space between the anterior and midaxillary lines in the zone of apposition between lung and liver.

Intervention Type DIAGNOSTIC_TEST

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Group 1

* Children aged 0-8 years old undergoing one of the following daycare procedures:
* Surgery: inguinal hernia and umbilical hernia surgery
* Urology: hypospadias surgery
* Throat/nose/ear surgery: tympanostomy tubes, removal of throat and nasal tonsils
* Orthopedics: congenital club feet surgery, hip luxation surgery, removing pins
* Plastic surgery: protruding ears surgery, removing of accessory auricle, removing additional toes and fingers - Ophthalmology: cataract and strabismus surgery
* Immunology: infusion therapy: e.g. prophylaxis of immunoglobulins

Group 2

-Children aged 0-8 years old recruited by colleagues, or relatives, friends and neighbours of members of the research group

Exclusion Criteria

Neuromuscular diseases

* Lung diseases
* Recent abdominal or thoracic surgery (less than 3 month ago) - Deviations of the diaphragm
Minimum Eligible Age

0 Months

Maximum Eligible Age

8 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Erasmus Medical Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Erwin Ista

PhD, Associate professor nursing science

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Erasmus MC-Sophia Children's Hospital

Rotterdam, , Netherlands

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Netherlands

References

Explore related publications, articles, or registry entries linked to this study.

Duyndam A, Smit J, Heunks L, Molinger J, IJland M, van Rosmalen J, van Dijk M, Tibboel D, Ista E. Reference values of diaphragmatic dimensions in healthy children aged 0-8 years. Eur J Pediatr. 2023 Jun;182(6):2577-2589. doi: 10.1007/s00431-023-04920-6. Epub 2023 Mar 20.

Reference Type DERIVED
PMID: 36939879 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

NL70476.078.19

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Ultra-low-dose Chest CT for HHT
NCT04874558 ACTIVE_NOT_RECRUITING
Effectiveness of Contrast-Enhanced Ultrasound
NCT03473249 ACTIVE_NOT_RECRUITING PHASE4