Relation of Non-invasively Measured Parameters to Clinical Outcomes in CHF Patients
NCT ID: NCT04548024
Last Updated: 2021-12-10
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
50 participants
OBSERVATIONAL
2020-09-10
2021-12-10
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
HF is characterized with a progressive course of disease with high hospital readmission rates, which account for a major portion of the economic burden. Improving the management of congestion has been a crucial component in the efforts to reduce hospitalizations. Congestion is a cardinal manifestation of HF, presenting with dyspnea, orthopnea, and edema due to volume overload. Diuretics remain a cornerstone in the management of congestion; however, there are no clear guidelines on how to adjust their administration. Guidelines recommend monitoring of daily weight changes, but efficacy is debatable. Thus, there is a pressing need to find reliable markers to promptly recognize deteriorations and help tailor diuretic treatment to prevent them. To date, European Society of Cardiology (ESC) guidelines recommend two invasive monitoring approaches to guide management, one based on invasive wireless pulmonary artery pressure monitoring and the other on utilizing data from Implantable Cardioverter Defibrillators (ICDs). Hemodynamic monitoring using invasive right heart catheterization has not shown benefit in management of HF decompensations, and nowadays is reserved only for specific clinical scenarios. In the field of non-invasive monitoring, research efforts have focused on analyzing lung impedance, ECG , and heart sounds with some promising results; a recent study utilized machine learning to generate a personalized alert system, but with a limited number of parameters monitored. Nevertheless, their algorithm's success in predicting hospitalizations reflects the importance of recognizing the heterogeneity of HF and the advantages of an individualized approach.
In this study, we will examine the use of a non-invasive, user-friendly device (BB-613WP, Biobeat Technologies LTD, Petah Tikva, Israel), in advanced HF patients receiving IV diuresis in a hospital outpatient clinic. The device can derive measurements of several parameters, including cardiac output (CO), cardiac index (CI), blood pressure (BP) and systemic vascular resistance (SVR) using photoplethysmography (PPG) technology, and has been tested in several clinical trials. We wish to assess if CO, CI and SVR can be utilized as markers for HF clinical course, so they can ideally be used to intervene and modify treatment prior to a deterioration.
The literature describing the effects of diuresis on CO and SVR is rather limited and archaic. Most studies found a reduction in CO and a rise in SVR after diuresis, but some describe the opposite, and some describe a response changing over time. This can be explained when considering that the pathophysiology underlying the effects of volume status on cardiac performance in HF is complex. The classically described Frank-Starling principle states that contractility peaks at a muscle length that allows for optimal overlap of actin and myosin filaments and maximal calcium ions sensitivity. Up to a certain point, the longer the muscle is (represented as larger EDV, end diastolic volume), the higher the force of contraction. But beyond that length, the contractile force decreases. Since different patients are characterized with different levels of cardiac filling, volume reduction induced by diuresis may have a different impact on CO, depending on the position on the Frank Starling curve. For instance, impaired ventricular filling in HF with preserved ejection fraction can reduce systolic function, due to less effective contraction in low EDV. Similarly, SVR, which is inversely proportional to CO, is likely to be affected differently. Our primary objective is to assess whether the changes in CO, CI and SVR during IV diuretic administration correlate with short-term clinical change measured using symptoms questionnaires, change in weight and urine output. Our secondary objective is to assess the correlation between baseline values of those parameters and long-term clinical outcomes, measured by HF hospitalizations and the change in disease perception and quality of life reported in questionnaires.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Short term monitoring
By using the Biobeat monitoring device, we will monitor CHF patients during an outpatient visit and during treatment with diuretics.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* A Recent echocardiography report (from the last 2 year)
* Treatment with IV diuresis at Hadassah Ein Kerem outpatient clinic
Exclusion Criteria
* Patient is under 18 years old
* Patient is unable to answer questions regarding his condition
* Pregnant women
* Worker from Hadassah Medical Center
18 Years
120 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Biobeat Technologies Ltd.
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Dean Nachman, MD
Role: PRINCIPAL_INVESTIGATOR
The Hadassah Ein Kerem Medical Center, Jerusalem, Israel
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
The Hadassah Ein Kerem Medical Center
Jerusalem, , Israel
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
PPGCHF001
Identifier Type: -
Identifier Source: org_study_id