Pre-operative Ultrasonographic Evaluation of the Internal Jugular Vein Collapsibility Index and Inferior Vena Cava Collapsibility Index to Predict Post Spinal Hypotension in Pregnant Women Undergoing Caesarean Section
NCT ID: NCT04519996
Last Updated: 2020-10-27
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
55 participants
INTERVENTIONAL
2020-10-30
2020-12-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Hemodynamic monitoring in obstetric patients has evolved during the last decade, with the development of minimally invasive and noninvasive continuous cardiac output (CO) monitors. Ultrasound (USG) is a method for noninvasive hemodynamic optimization in the ICU and ED, and it may be more helpful than other noninvasive methods. Transabdominal USG measurements of inferior vena cava (IVC) are noninvasive and thus are not associated with complications. USG of the IVC diameter is a useful and easy method for assessing a patient's volume status by calculating the IVC collapsibility index (IVCCI).
Recently, the usefulness of point-of-care ultrasonographic examination, performed by anesthesiologists in real time, for perioperative management has been reported . Ultrasonographic studies have established the utility of measuring the inferior vena cava (IVC) or internal jugular Vein (IJV) for evaluating intravascular volume status .
In particular, IVC diameter and collapsibility, obtained from ultrasonographic measurement, have been demonstrated to be predictors of hypotension after anesthetic administration.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Machine
A sonosite M-Turbo ultrasound machine will be used for all the examinations. A curvilinear USG probe for IVC imaging (1-5 MHz, 21 mm). A linear vascular transuder for IJV imaging (7-13 MHz, 38 mm) will be used.
Measurements
IJV measurement
All the measurements will be done on Right IJV with the patients initially lying supine at 0° and later head end elevated at 30°. With the patients in supine position, the USG transducer will be placed on the right side of the neck in the transverse plane over RIJV 2 cm above the sternoclavicular joint. The IJV will be identified by the color flow Doppler and compressibility. Care will be taken not to compress or obliterate the vein by applying minimal pressure. When the whole circumference of the vein will be visible the measurements were done. The recordings will be done for four respiratory cycles. The maximum, minimum AP diameters, and cross-sectional area will be estimated and, from this, corresponding CI will be derived (Maximum diameter or cross-sectional area (CSA)-minimum diameter or CSA/maximum diameter or CSA) ×100%. All the above measurements will be repeated with the head end of patients elevated to 30° position
IVC measurements
The transducer will be placed in the subxiphoid region in a longitudinal position. IVC measurements will be made just distal to the IVC-hepatic vein junction, approximately 3 to 4 cm distal to the right atrium. The IVC will be identified by Doppler waveform, compressibility and phasic collapse with respiration. The maximum (IVCD) and minimum (IVCD) internal anteroposterior (AP) diameters of the IVC at the end of expiration and inspiration respectively over the same respiratory cycle will be measured. The IVCCI is derived from the equation, IVCCI= (IVCD max -IVCD min)/IVCD max × 100.
The patients will be positioned in sitting position to give the spinal anesthesia at L3-L4/L2-L3 intervertebral level in the midline approach. After local infiltration of skin and subcutaneous tissue with 2% lignocaine, 25 G B-braun spinal needle will be used to administer subarachnoid block (SAB) with 2.5 ml of hyperbaric bupivacaine (5%) and 20 µg of fentanyl after confirmation of free flow of cerebrospinal fluid (CSF) at the hub of the needle. Patients will be coloaded with 10-12 ml/kg (over the period of 15 min) of Ringer's Lactate (RL) solution at the time of SAB. Thereafter, patients will be placed in supine position with wedge under the right hip. HR, systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), and SpO2 will be recorded throughout the procedure every 3 min till 15 min of SAB. Level of sensory block will be assessed by response to cold touch and surgery will be allowed after sensory blocks reaches to T6 level. Hypotension (reduction in MAP more than 20% and/or MAP \<65 mmHg) will be treated with 6 mg of injection of ephedrine and a bolus of 250 ml of Ringer's Lactate (RL) solution over 10 minutes. Number of boluses of ephedrine and fluids will be recorded. Bradycardia (Heart Rate \< 50 beats/ min) will be treated with 0.6 mg of injection atropine.
Data collection
The attending anaesthesiologist who will perform subarachnoid block (SAB) and will monitor the patient during the study period will be blinded to the ultrasound measurements of both inferior vena cava collapsibility index (IVCCI) and internal jugular vein collapsibility index (IJVCI) which will be recorded by either of the two investigators pre-operatively.
Measurements:
1. Demographic data as age, weight, height and ASA status.
2. Hemodynamics including heart rate, mean arterial blood pressure every 3 min till 15 min of SAB.
3. Number of boluses of ephedrine and fluids will be recorded
4. Inferior vena cava collapsibility index (IVCCI) and internal jugular vein collapsibility index (IJVCI).
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
PREVENTION
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
US Internal Jugular Vein Collapsibility Index
The US transducer will be placed on the right side of the neck in the transverse plane over RIJV 2 cm above the sternoclavicular joint. The IJV will be identified by the color flow Doppler and compressibility.
US Internal Jugular Vein Collapsibility Index measurment
Machine
A sonosite M-Turbo ultrasound machine will be used for all the examinations. A curvilinear USG probe for IVC imaging (1-5 MHz, 21 mm).
The US transducer will be placed on the right side of the neck in the transverse plane over RIJV 2 cm above the sternoclavicular joint. The IJV will be identified by the color flow Doppler and compressibility. Care will be taken not to compress or obliterate the vein by applying minimal pressure. When the whole circumference of the vein will be visible the measurements were done. The recordings will be done for four respiratory cycles. The maximum, minimum AP diameters, and cross-sectional area will be estimated and, from this, corresponding CI will be derived (Maximum diameter or cross-sectional area (CSA)-minimum diameter or CSA/maximum diameter or CSA) ×100%. All the above measurements will be repeated with the head end of patients elevated to 30° position.
US Inferior Vena Cava Collapsibility Index
The transducer will be placed in the subxiphoid region in a longitudinal position. IVC measurements will be made just distal to the IVC-hepatic vein junction, approximately 3 to 4 cm distal to the right atrium. The IVC will be identified by Doppler waveform, compressibility and phasic collapse with respiration.
US Inferior Vena Cava Collapsibility Index measurment
Machine
A sonosite M-Turbo ultrasound machine will be used for all the examinations. A linear vascular transuder for IJV imaging (7-13 MHz, 38 mm) will be used.
The transducer will be placed in the subxiphoid region in a longitudinal position. IVC measurements will be made just distal to the IVC-hepatic vein junction, approximately 3 to 4 cm distal to the right atrium. The IVC will be identified by Doppler waveform, compressibility and phasic collapse with respiration. The maximum (IVCD) and minimum (IVCD) internal anteroposterior (AP) diameters of the IVC at the end of expiration and inspiration respectively over the same respiratory cycle will be measured. The IVCCI is derived from the equation, IVCCI= (IVCD max -IVCD min)/IVCD max × 100.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
US Internal Jugular Vein Collapsibility Index measurment
Machine
A sonosite M-Turbo ultrasound machine will be used for all the examinations. A curvilinear USG probe for IVC imaging (1-5 MHz, 21 mm).
The US transducer will be placed on the right side of the neck in the transverse plane over RIJV 2 cm above the sternoclavicular joint. The IJV will be identified by the color flow Doppler and compressibility. Care will be taken not to compress or obliterate the vein by applying minimal pressure. When the whole circumference of the vein will be visible the measurements were done. The recordings will be done for four respiratory cycles. The maximum, minimum AP diameters, and cross-sectional area will be estimated and, from this, corresponding CI will be derived (Maximum diameter or cross-sectional area (CSA)-minimum diameter or CSA/maximum diameter or CSA) ×100%. All the above measurements will be repeated with the head end of patients elevated to 30° position.
US Inferior Vena Cava Collapsibility Index measurment
Machine
A sonosite M-Turbo ultrasound machine will be used for all the examinations. A linear vascular transuder for IJV imaging (7-13 MHz, 38 mm) will be used.
The transducer will be placed in the subxiphoid region in a longitudinal position. IVC measurements will be made just distal to the IVC-hepatic vein junction, approximately 3 to 4 cm distal to the right atrium. The IVC will be identified by Doppler waveform, compressibility and phasic collapse with respiration. The maximum (IVCD) and minimum (IVCD) internal anteroposterior (AP) diameters of the IVC at the end of expiration and inspiration respectively over the same respiratory cycle will be measured. The IVCCI is derived from the equation, IVCCI= (IVCD max -IVCD min)/IVCD max × 100.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
2. Emergency LSCS
3. Patients with expected massive intraoperative blood loss e.g. placenta Previa and placenta accreta
4. Cardiovascular, respiratory, renal diseases
5. Patients who will receive preloading of intravenous fluid
20 Years
40 Years
FEMALE
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Tanta University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Amr Arafa Elbadry
Principal Investigator
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IJVCI versus IVCCI
Identifier Type: -
Identifier Source: org_study_id