MAgnetic Gastrointestinal Universal Septotome: a Safety and Feasibility Study (MAGUS)
NCT ID: NCT04480216
Last Updated: 2021-12-08
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
16 participants
INTERVENTIONAL
2020-02-19
2021-09-15
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Esophageal diverticula consists in the apparition of a pouch (diverticulum) alongside the esophagus. Some post-surgical conditions can result in the appearance of pseudo-diverticulum or afferent limb that transforms into a large pouch. One example is the candy cane syndrome, being an afferent loop syndrome post gastrectomy or post Roux-en-Y Gastric Bypass, were the afferent limb becomes a structure similar to a large diverticulum.
All those pathological conditions could be solved by the marsupialization of those (pseudo-)diverticulum. For several years, Zenker's diverticula (pharyngo-esophageal diverticulum) have been treated endoscopically using this technique, providing good clinical results. However, it is difficult to go further than the pharynx with this technique, since it needs specific semi-rigid tools and a stable cutting position. Hence, for further septa of the GI tract, the classic treatment is thoracoscopy and thoracotomy or laparoscopy and laparotomy, depending on the site. Those highly invasive procedures have a significant mortality and morbidity rate respectively of more than 5% and 20% and are liked to different complications including abdominal pain, port site wound infections, intraabdominal collection or anastomosis ulcer.
The MAGUS device consists of a flexible catheter preloaded with a magnetic device, made of two magnets linked by a wire. Each magnet is attached to the catheter and can be dropped separately from this catheter. The magnetic device aims to create an anastomosis by means of compression, using magnetic force and a retractable wire pulling system. For a given septum, the magnets are placed on either sides of the bottom of it. The retractable wire goes then from one another, passing on top of the septum. Both creates compression necrosis. This process induces eventually a cutting of the septum.
Once the cutting is performed, the magnets migrate and are expelled through natural ways.
The MAGUS device is an endoscopic procedure. Above standard of care monitoring, safety assessment of the procedure and device performance decreases the risk and unforeseen events.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
MAGUS
An upper endoscopy will be performed with the use of fluoroscopy. The MAGUS will be placed under fluoroscopy. The good positioning and the absence of any complications will be confirmed by gastroscopy.
An injection of contrast agent will be done to be sure of the correct positioning and that no complications was happened.
The patient will be kept overnight, with liquid food for 2 and mashed food up to 7 days post procedure
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patient has got evaluable symptoms (dysphagia, regurgitation, pain, weight loss, halitosis or others) associated with one of the following pathology:
1. Diverticulum of the esophagus;
2. A pseudo-diverticulum of the upper GI tract;
3. Candy cane syndrome;
* Willing and able to comply with the study procedures and provide written informed consent to participate in the study.
Exclusion Criteria
* Septum height smaller than 2,5 cm or higher than 6 cm (check through CT scan, Barium Swallow or other imaging method);
* Coagulation disorders;
* Previous implantation of a magnetic-sensitive medical device (including active electronic implant, metallic stent, …);
* Dysphagia related to motility disorder;
* Planned MRI in the following month (30 days) of intervention.
* Concurrent medical condition that would affect the investigator's ability to evaluate the patient's condition or could compromise patient safety;
* Patient went through a surgery less than 8 weeks before implantation of the magnets;
* Currently enrolled in another clinical trial.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Erasme University Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hopital Erasme
Brussels, , Belgium
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Rio-Tinto R, Huberland F, Van Ouytsel P, Delattre C, Dugardeyn S, Cauche N, Delchambre A, Deviere J, Blero D. Magnet and wire remodeling for the treatment of candy cane syndrome: first case series of a new approach (with video). Gastrointest Endosc. 2022 Jun;95(6):1247-1253. doi: 10.1016/j.gie.2021.12.027. Epub 2022 Jan 1.
Huberland F, Rio-Tinto R, Cauche N, Dugardeyn S, Delattre C, Sandersen C, Rocq L, van Ouytsel P, Delchambre A, Deviere J, Blero D. Magnets and a self-retractable wire for endoscopic septotomies: from concept to first-in-human use. Endoscopy. 2022 Jun;54(6):574-579. doi: 10.1055/a-1554-0976. Epub 2021 Oct 29.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
P2019/643
Identifier Type: -
Identifier Source: org_study_id