White Test in Intra-operative Detection of Donor Biliary Leak in LDLTx.
NCT ID: NCT04451447
Last Updated: 2020-06-30
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
60 participants
INTERVENTIONAL
2019-03-20
2020-06-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
In this study we will assess the efficacy and sensitivity of using White test in comparison to conventional saline test in detecting intra operative bile leakage in liver donor.
The White test uses fat emulsion (SMOFLIPID), which is a lipid emulsion with a lipid content of 0.2 grams/mL in 100 mL, 250 mL, and 500 Ml that is normally used for parenteral nutrition, for localization of bile leakage. The use of fat emulsion in bile leakage tests does not require special equipment, contaminate the wound, cause allergic reaction or damage the bile duct and surrounding tissues.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The timely detection and repair of intraoperative bile leakage is extremely important, but small leakage points are often difficult to detect \[ Liu Z et al, 2012 \]. There are different methods for detecting and or preventing bile leakage after partial liver resection, including bile leakage tests, which detect open bile duct stumps on the resection surface through increasing fluid pressure within the duct \[ Lo CM et al, 1998 \].
The conventional intraoperative saline test, which involves injecting an isotonic sodium chloride solution through the cystic duct, has been used for detection of leaking points from the transected liver surface \[ Ijichi M et al, 2000 \]. One of the main problems in using the conventional bile leakage test is that the isotonic sodium chloride solution is a transparent solution. Therefore, it is hard to detect the point of bile leakage. A previous randomized study stated that there is no advantage to using the isotonic sodium chloride solution for the bile leakage test during liver resection \[ Ijichi M et al, 2000 \].
During the past decade, several bile leak tests have been proposed, with none gaining wide acceptance. The intraductal injection of saline is a low-cost and reproducible technique, but the transparent solution makes this technique inadequate for detecting small ducts. The injection of dye solutions (e.g. methylene blue and indocyanine green) has been recommended. However, these solutions need to be dense in order to allow the visualization of the leak site. The related disadvantages of this approach include the following: 1) the indelible coloration of the transection surface, which can mask additional small open ducts, 2) the impossibility to wash out the staining and, consequently, 3) potential reduced sensitivity for the detection of leak with repeated tests. Some centres have reported the saturation of the cut surface of the liver with hydrogen peroxide to detect bile leaks, however this practice comes with a potential risk of expansion air embolism via open hepatic veins.
The White test uses fat emulsion (SMOFLIPID), which is a lipid emulsion with a lipid content of 0.2 grams/mL in 100 mL, 250 mL, and 500 Ml that is normally used for parenteral nutrition, for localization of bile leakage (Morris-Stiff G et al., 2009). The use of fat emulsion in bile leakage tests does not require special equipment, contaminate the wound, cause allergic reaction or damage the bile duct and surrounding tissues. It can easily be repeated the number of times necessary to detect and close all leakage points, can pinpoint even small leaks and is inexpensive. This technique is easier to perform than fluorescent imaging, and is more sensitive and reliable compared with saline bile leakage test used alone (Leelawat K et al., 2012; Kaibori M et al., 2011).
Recently, intraoperative application of the White test has been demonstrated to reduce the incidence of postoperative bile leakage \[ Li J et al, 2009 \] \[ Nadalin S et al, 2008 \]. In this technique, bile leakage sites on the transected liver surface are noted by injecting a fat emulsion solution through the cystic duct. The previous prospective observational studies suggested that the fat emulsion solution used in the White test is easily recognized, innocuous and harmeless to the tissues, and can be easily removed without misleading tissue staining \[ Li J et al, 2009 \] \[ Nadalin S et al, 2008 \]. Therefore, this prospective study will assess whether the White test is better than the conventional saline test for the intraoperative detection of bile leakage and better prevention of post-operative bile leakage in partial resection in living donor liver transplant.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
PREVENTION
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
white test arm
The White test uses fat emulsion (SMOFLIPID), which is a lipid emulsion with a lipid content of 0.2 grams/mL in 100 mL, 250 mL, and 500 Ml that is normally used for parenteral nutrition, for localization of bile leakage.
The White test uses fat emulsion (SMOFLIPID), for localization of bile leakage.
The White test uses fat emulsion (SMOFLIPID), which is a lipid emulsion with a lipid content of 0.2 grams/mL in 100 mL, 250 mL, and 500 Ml that is normally used for parenteral nutrition, for localization of bile leakage.
Saline test arm
The conventional intra-operative saline test, which involves injecting an isotonic sodium chloride solution through the cystic duct, has been used for detection of leaking points from the transected liver surface.
Saline test (routine test)
The conventional intra-operative saline test, which involves injecting an isotonic sodium chloride solution through the cystic duct, has been used for detection of leaking points from the transected liver surface.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
The White test uses fat emulsion (SMOFLIPID), for localization of bile leakage.
The White test uses fat emulsion (SMOFLIPID), which is a lipid emulsion with a lipid content of 0.2 grams/mL in 100 mL, 250 mL, and 500 Ml that is normally used for parenteral nutrition, for localization of bile leakage.
Saline test (routine test)
The conventional intra-operative saline test, which involves injecting an isotonic sodium chloride solution through the cystic duct, has been used for detection of leaking points from the transected liver surface.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. BMI must be up to 28.
3. Blood group must be compatible; Rh compatibility was not a significant criterion.
4. Donors should have normal liver function and no medical comorbidities.
5. Liver biopsy was done to ensure that there is no occult hepatic pathology and to establish the degree of steatosis that should be less than 20%.
6. Donors must have no history of upper abdominal surgery.
Exclusion Criteria
18 Years
45 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Amr Abdelaal
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Amr Abdelaal
professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
amr abdelaal, prof
Role: PRINCIPAL_INVESTIGATOR
Ain Shams University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Ain Shams University
Cairo, , Egypt
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
White test in LDLTx
Identifier Type: -
Identifier Source: org_study_id