Detection of antibodies directed against SARS-CoV-2 by various detection kits is currently under evaluation. To the lack of serological test kits on the French market is added the complexity of verifying the sensitivity and specificity of these tests. On the other hand, the immune response to SARS-CoV-2 is complex and still quite unknown. The concomitant presence of several isotypes IgA, IgM and IgG is frequently observed. Thus, the isotypic switching of Ig does not seem to take place correctly in this disease case, which randers the serodiagnostics even more complicated to implement. Detection of the less specific IgMs would therefore be essential, in the case of SARS-CoV-2. Rheumatoid factor (RF) is an immunoglobulin (Ig), more often of the M type, directed against the Fc fragment of IgG. This antibody, although not directly pathogenic, is very frequently present in RA patients (70 to 80%), without being specific for this pathology since it can be observed in other autoimmune, infectious or hematological diseases as well. The presence of RF IgM, all the more in high titers, is problematic while performing many serological or immunological assays since these high levels can be responsible for false positive results.
During previous SARS epidemics (SARS-CoV-1 or MERS-CoV), false positive results of serological tests were observed. When detecting anti-SARS-CoV-1 IgG or IgM in patients who had not contracted SARS, the use of an ELISA kit, with plates coated with a cell lysate of Vero-E6 cells infected with SARS-CoV-1, had been shown to induce a low number of false positive results in healthy controls (less than 5%). However, the number of false positive results in patients with autoimmune diseases was much higher, and varied accordingly with the pathology (between 10% and 58%), the largest number of false positive results being obtained in lupus patients. This phenomenon can be explained by the use of an immune test using unpurified cell lysates, which contain antigens against which the autoantibodies present in the patient serum could react, thus distorting the outcome of the test. Other causes of increase in the false positive results rate have been described when performing SARS-CoV-1 serologies, such as the presence of active neoplasia, or because of a previous infection with another coronavirus. Indeed, other coronaviruses, such as HCoV-OC43 and HCoV-229E, display a nucleocapsid close to the one of SARS-CoV-1 : this similarity can be the source of cross-reactivity. The same phenomenon was observed with the latest coronavirus: it was therefore suggested to rather use recombinant antigens of SARS-CoV-2 in immunoassays, such as ELISA for instance Given the similarity between SARS-CoV1 and SARS-CoV2, it is likely that the various elements causing false positive results during serological tests for SARS-CoV-1, in particular the presence of auto-antibodies including RF, could also cause false positive results when performing serological tests targeting SARS-CoV-2. A recent Chinese study showed that a moderate or high rate of RF was associated with a significant rate of false positive results when searching for anti-SARS-CoV-2 IgM with a ELISA kit, which plates were however coated with recombinant antigen. The authors therefore proposed to include a urea dissociation step into the ELISA protocol, which seemed to improve the specificity of the test, without altering its sensitivity.
It thus appears essential to assess the influence of RF, for its different isotypes (IgG, IgM, IgA), on various serological tests for SARS-CoV-2 available in France, in order to better assess these tests specificity.
The investigators propose to evaluate and compare 3 different serological tests available for the detection of specific SARS-CoV-2 IgG and IgM. The rate of false positive results obtained for each type of test will be evaluated on sera originated from patients with RA who have never been in contact with SARS-CoV-2, since these sera were withdrawn before July 2019. The relation between the incidence of SARS-Cov-2 serological assays false positive results and RF antibody levels could be estimated, as well as the characterization of RF.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
RETROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Groupe 1
Group 1: Rheumatoid arthritis seropositive for RF (+)
Serological analyses to be lead on a pre-existing biobank
3 immunoassays will be used according to the procedure described (Demey-2020; Tuaillon-2020) :
* WuHan UNscience Biotechnology Co., Ltd (Chine). COVID-19 IgG/IgM Rapid Test Kit, (Wuhan, China), will be refered as UNscience
* Chongqing iSIA BIO-Technology Co., Ltd (Chine). 2019-nCoV IgM/IgG Diagnostic Test Kit ; (Chongqing, China), will be refered as iSIA
* Xiamen Biotime Biotechnology Co. Ldt (Chine). (SARS-CoV-2) IgM/IgG Rapid Qualitative Test Kit, will be refered as Biotime.
Groupe 2
Group 2: Rheumatoid arthritis seronegative for RF (-)
Serological analyses to be lead on a pre-existing biobank
3 immunoassays will be used according to the procedure described (Demey-2020; Tuaillon-2020) :
* WuHan UNscience Biotechnology Co., Ltd (Chine). COVID-19 IgG/IgM Rapid Test Kit, (Wuhan, China), will be refered as UNscience
* Chongqing iSIA BIO-Technology Co., Ltd (Chine). 2019-nCoV IgM/IgG Diagnostic Test Kit ; (Chongqing, China), will be refered as iSIA
* Xiamen Biotime Biotechnology Co. Ldt (Chine). (SARS-CoV-2) IgM/IgG Rapid Qualitative Test Kit, will be refered as Biotime.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Serological analyses to be lead on a pre-existing biobank
3 immunoassays will be used according to the procedure described (Demey-2020; Tuaillon-2020) :
* WuHan UNscience Biotechnology Co., Ltd (Chine). COVID-19 IgG/IgM Rapid Test Kit, (Wuhan, China), will be refered as UNscience
* Chongqing iSIA BIO-Technology Co., Ltd (Chine). 2019-nCoV IgM/IgG Diagnostic Test Kit ; (Chongqing, China), will be refered as iSIA
* Xiamen Biotime Biotechnology Co. Ldt (Chine). (SARS-CoV-2) IgM/IgG Rapid Qualitative Test Kit, will be refered as Biotime.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University Hospital, Montpellier
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Rosanna FERREIRA, MD
Role: PRINCIPAL_INVESTIGATOR
UH Montpellier
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Uhmontpellier
Montpellier, , France
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
RECHMPL20_0330
Identifier Type: -
Identifier Source: org_study_id