Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
80 participants
INTERVENTIONAL
2020-11-01
2022-06-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Methods: We will conduct a multicenter, randomized, controlled trial (N=80) in high-risk surgical patients scheduled for elective major abdominal surgery. All participants will be randomly assigned to a control or intervention group. Hemodynamic management in the control group will be based on standard hemodynamic parameters. Hemodynamic management of patients in the intervention group will be based on functional hemodynamic parameters provided by Hemosphere platform (Edwards Lifesciences Ltd), including dynamic arterial elastance, dP/dtmax and the Hypotension Prediction Index. Tissue oxygen saturation will be non-invasively and continuously recorded by using near-infrared spectroscopy technology. Biomarkers of acute kidney stress (cTIMP2 and IGFBP7) will be obtained before and after surgery. The primary outcome will be intraoperative time-weighted average with a mean arterial pressure \< 65mmHg.
Discussion: The aim of the study is to determine whether a goal-directed algorithm based on the prevention of arterial hypotension using the Hypotension Prediction Index reduces the duration and severity of intraoperative hypotension when compared with the recommended standard therapy and if this intraoperative strategy affects tissue oxygenation and organ perfusion.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
PREVENTION
TRIPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Experimental
Hemodynamic management will be based on the functional hemodynamic parameters provided by Hemosphere platform with the Acumen IQ sensor, including cardiac output, stroke volume, SVV and Acumen IQ specific parameters: maximal arterial pressure rise (dP/dtmax), dynamic arterial elastance (Eadyn) and HPI
As a pattern replacement of interstitial space, we will use balanced crystalloid (Isofundin®) at 1-3 ml / kg / h in case of laparoscopic surgery and 5 to 7 ml / kg / h in case of open surgery.
The protocol of action on the intravascular space will be based on the maintenance of systolic volume with colloids (hydroxyethyl starch - Voluvén®).
Hemosphere platform® together with the FloTrac Acumen IQ® sensor
Clinical platform that, analyzing the pulse wave contour, obtained from the previously catheterized radial artery, is able to make available to the clinician both a continuous monitoring of blood pressure and advanced hemodynamic parameters that help patient management. It incorporates predictive parameters such as the hypotension prediction index and decision support parameters such as dynamic arterial elastance and maximum dP / dT.
It also has the possibility of assessing regional oxygen saturation, measured by near-infrared light photoplethysmography, and the sensor can be applied in different locations (cerebral, muscular ...).
Control
Hemodynamic management will be based on the functional hemodynamic parameters provided by the HemoSphere platform® with the FloTrac® sensor, including cardiac output (CO), stroke volume (SV), and stroke volume variation (SVV)
As a pattern replacement of interstitial space, we use balanced crystalloid (Isofundin®) at 1-3 ml / kg / h in case of laparoscopic surgery and 5 to 7 ml / kg / h in case of open surgery.
The protocol action for the intravascular space will be based on a recently published hemodynamic optimization algorithm (Heming N, Moine P, Coscas R, Annane D. Perioperative fluid management for major elective surgery. British Journal of Surgery. 2020;107:e56-62). The fluid used will be hydroxyethyl starch (Voluven®).
Hemosphere platform® together with the FloTrac® sensor
Clinical platform that, analyzing the pulse wave contour, obtained from the previously catheterized radial artery, is able to make available to the clinician both a continuous monitoring of blood pressure and advanced hemodynamic parameters that help patient management.
It also has the possibility of assessing regional oxygen saturation, measured by near-infrared light photoplethysmography, and the sensor can be applied in different locations (cerebral, muscular ...).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Hemosphere platform® together with the FloTrac Acumen IQ® sensor
Clinical platform that, analyzing the pulse wave contour, obtained from the previously catheterized radial artery, is able to make available to the clinician both a continuous monitoring of blood pressure and advanced hemodynamic parameters that help patient management. It incorporates predictive parameters such as the hypotension prediction index and decision support parameters such as dynamic arterial elastance and maximum dP / dT.
It also has the possibility of assessing regional oxygen saturation, measured by near-infrared light photoplethysmography, and the sensor can be applied in different locations (cerebral, muscular ...).
Hemosphere platform® together with the FloTrac® sensor
Clinical platform that, analyzing the pulse wave contour, obtained from the previously catheterized radial artery, is able to make available to the clinician both a continuous monitoring of blood pressure and advanced hemodynamic parameters that help patient management.
It also has the possibility of assessing regional oxygen saturation, measured by near-infrared light photoplethysmography, and the sensor can be applied in different locations (cerebral, muscular ...).
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Edwards Lifesciences
INDUSTRY
Juan Victor Lorente
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Juan Victor Lorente
Anesthesiologist
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hospital Universitario de Jerez de la Frontera
Jerez de la Frontera, Cádiz, Spain
Hospital Universitario de Badajoz
Badajoz, , Spain
Hospital Universitario Juan Ramón Jiménez
Huelva, , Spain
Hospital Universitario Infanta Leonor
Madrid, , Spain
Hospital Universitario Virgen del Rocío
Seville, , Spain
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Lorente JV, Jimenez I, Ripolles-Melchor J, Becerra A, Wesselink W, Reguant F, Mojarro I, Fuentes MLA, Abad-Motos A, Agudelo E, Herrero-Machancoses F, Callejo P, Bosch J, Monge MI. Intraoperative haemodynamic optimisation using the Hypotension Prediction Index and its impact on tissular perfusion: a protocol for a randomised controlled trial. BMJ Open. 2022 Jun 2;12(6):e051728. doi: 10.1136/bmjopen-2021-051728.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
v 1.0; March 2019
Identifier Type: -
Identifier Source: org_study_id