Comparison of Pinless Navigation and Conventional Method in Total Knee Arthroplasty
NCT ID: NCT04235283
Last Updated: 2020-01-31
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
100 participants
INTERVENTIONAL
2019-05-01
2020-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
However, MIS-TKA procedures require a long learning curve to avoid malposition of prosthesis. In previous studies have demonstrated that the position of prosthesis and the postoperative mechanical axis are critical factors of outcome. Malposition of prosthesis and deviation more than 3 degrees of mechanical axis will lead to asymmetrical tibia-femoral tracking between prosthesis with the wear of linear, and increase the incidence of prosthesis loosening.
Computer navigation assisted system has been used in TKA procedures for more than one decade and has been proven to improve the accuracy of prosthesis placement and postoperative mechanical alignment. Moreover, navigated TKA avoids the use of intramedullary guide and preserve the medullary cavity of femur, so the risks of bleeding and venous thromboembolism are reduced. However, traditional navigation system requires additional procedure to set reference arrays with pin fixation of femur and tibia. Pin wound complications including bleeding, infection, and iatrogenic fracture were reported. Moreover, traditional navigation system requires conventional TKA approach in which the wound length of the knee will be as long as 15 to 20 cm. Therefore a combination of new navigation system with a MIS technique to perform TKA procedure is required The new pinless navigated system for TKA procedures has been developed, as the navigation tools were fixed in the surgical field without additional pin wounds. This advantage meets the rationale of MIS-TKA to take care of both minimal invasive procedures and accuracy of prosthesis placement. Therefore, the investigators want to investigate the application of this pinless navigation system in MIS-TKA procedures.
Our purpose is to conduct a prospective randomized clinical trial to compare the accuracy of prosthesis, radiographic alignment, total blood loss, the risk of venous thromboembolism between pinless-navigated MIS-TKA and traditional MIS-TKA.
Material and Methods:
The investigators plan to enroll 100 patients who plan to undergo unilateral primary MIS-TKA and will be randomly assigned into two groups. The first group (50 patients) will be treated by pinless-navigation (Stryker, OrthoMap Express Knee Navigation) MIS-TKA, and the second group (50 patients) will undergo traditional MIS-TKA.
The investigators will record the surgical wound length, surgical time cost and calculate daily hemoglobin drainage and total blood loss after TKA procedures for all patients. At 3 months after operation, the whole leg scanography, AP and lat view of knee radiography will be take and the mechanical alignment (MA), anatomic alignment (AA), femoral bowing angle (FBA), and coronal femoral-component angle (CFA), coronal tibia-component angle (CTA) in coronary view and sagittal femoral component angle (SFA), sagittal tibial component angle (STA) in lateral view will be measured. The operating time and surgical wound length in knee full extension will be recorded. All complications including bleedings, wound complications, venous thromboembolism will be recorded.
Study year: one year Expecting Result The investigators anticipate that the position of prosthesis in pinless-navigated MIS-TKA is more accurate or equal to traditional MIS-TKA group. And the total blood loss in pinless-navigated MIS-TKA is less than traditional MIS-TKA group. The complication rate is similar between the two groups
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Group I
Primary total knee replacement by pinless navigation and minimally invasive technique
Primary total knee replacement by pinless navigation (Orthomap Express,Stryker, Michigan)
The varus/valgus, extension/flexion, thickness of distal cut of femur was determined and done by pinless navigation system. After cutting, the instant information of resection level can show on the display screen. If the alignment is satisfying, the anterior/posterior femoral cut, chamfer cut and box resection were done by conventional jig
Group II
Primary total knee replacement by traditional jig and minimally invasive technique
Primary total knee replacement by traditional jig and minimally invasive technique
The femoral alignment was determined by intramedullary guide. The femoral alignment jig was set to 5-7 degree valgus dependent on the preoperative radiograph. A bone plug is impacted into the entry hole of femoral medullary canal before prosthesis placement.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Primary total knee replacement by pinless navigation (Orthomap Express,Stryker, Michigan)
The varus/valgus, extension/flexion, thickness of distal cut of femur was determined and done by pinless navigation system. After cutting, the instant information of resection level can show on the display screen. If the alignment is satisfying, the anterior/posterior femoral cut, chamfer cut and box resection were done by conventional jig
Primary total knee replacement by traditional jig and minimally invasive technique
The femoral alignment was determined by intramedullary guide. The femoral alignment jig was set to 5-7 degree valgus dependent on the preoperative radiograph. A bone plug is impacted into the entry hole of femoral medullary canal before prosthesis placement.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Age \> 50 years and \< 90 years
3. Failure of medical treatment or rehabilitation.
4. Hemoglobin \> 11g/dl,
5. No use of non-steroid anti-inflammatory agent one week before operation
Exclusion Criteria
2. History of infection or intraarticular fracture of the affective knee
3. Renal function deficiency (GFR \<30 ml/min/1.73m2)
4. Elevated liver enzyme (AST/ALT level are more than twice normal range) , history of liver cirrhosis, impaired liver function(elevated total bilirubin level) and coagulopathy (including long-term use anticoagulant)
5. History of deep vein thrombosis, ischemic heart disease, cardiac arrythmia requiring life-long anti-coagulants, or stroke
6. Contraindications of tranexamic acid, rivaroxaban, or the excipients
7. Allergy to tranexamic acid, rivaroxaban, or the excipients
8. Coagulopathy or bleeding tendency caused by organ dysfunction, such as cirrhosis, bone marrow suppression etc.
9. Patient who have active bleeding disorder, such as intracranial hemorrhage, upper GI bleeding, hematuria
50 Years
90 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Chang Gung Memorial Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Jun-Wen Wang, MD
Role: STUDY_DIRECTOR
Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Kaohsiung Chang Gung Memorial Hospital
Kaohsiung City, , Taiwan
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Jun-Wen Wang, MD
Role: primary
References
Explore related publications, articles, or registry entries linked to this study.
Zhang Z, Zhu W, Gu B, Zhu L, Chen C. Mini-midvastus versus mini-medial parapatellar approach in total knee arthroplasty: a prospective, randomized study. Arch Orthop Trauma Surg. 2013 Mar;133(3):389-95. doi: 10.1007/s00402-012-1645-x. Epub 2012 Dec 11.
Nestor BJ, Toulson CE, Backus SI, Lyman SL, Foote KL, Windsor RE. Mini-midvastus vs standard medial parapatellar approach: a prospective, randomized, double-blinded study in patients undergoing bilateral total knee arthroplasty. J Arthroplasty. 2010 Sep;25(6 Suppl):5-11, 11.e1. doi: 10.1016/j.arth.2010.04.003. Epub 2010 Jun 11.
Dalury DF, Dennis DA. Mini-incision total knee arthroplasty can increase risk of component malalignment. Clin Orthop Relat Res. 2005 Nov;440:77-81. doi: 10.1097/01.blo.0000185757.17401.7b.
Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004 Nov;(428):26-34. doi: 10.1097/01.blo.0000148578.22729.0e.
King J, Stamper DL, Schaad DC, Leopold SS. Minimally invasive total knee arthroplasty compared with traditional total knee arthroplasty. Assessment of the learning curve and the postoperative recuperative period. J Bone Joint Surg Am. 2007 Jul;89(7):1497-503. doi: 10.2106/JBJS.F.00867.
Zhang Z, Gu B, Zhu W, Zhu L, Li Q, Du Y. Minimal invasive and computer-assisted total knee replacement compared with the minimal invasive technique: a prospective, randomized trial with short-term outcomes. Arch Orthop Trauma Surg. 2014 Jan;134(1):65-71. doi: 10.1007/s00402-013-1879-2. Epub 2013 Nov 8.
Seon JK, Song EK, Yoon TR, Park SJ, Bae BH, Cho SG. Comparison of functional results with navigation-assisted minimally invasive and conventional techniques in bilateral total knee arthroplasty. Comput Aided Surg. 2007 May;12(3):189-93. doi: 10.3109/10929080701311861.
Dutton AQ, Yeo SJ, Yang KY, Lo NN, Chia KU, Chong HC. Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study. J Bone Joint Surg Am. 2008 Jan;90(1):2-9. doi: 10.2106/JBJS.F.01148.
Luring C, Beckmann J, Haibock P, Perlick L, Grifka J, Tingart M. Minimal invasive and computer assisted total knee replacement compared with the conventional technique: a prospective, randomised trial. Knee Surg Sports Traumatol Arthrosc. 2008 Oct;16(10):928-34. doi: 10.1007/s00167-008-0582-2. Epub 2008 Jul 17.
Hasegawa M, Yoshida K, Wakabayashi H, Sudo A. Minimally invasive total knee arthroplasty: comparison of jig-based technique versus computer navigation for clinical and alignment outcome. Knee Surg Sports Traumatol Arthrosc. 2011 Jun;19(6):904-10. doi: 10.1007/s00167-010-1253-7. Epub 2010 Sep 1.
Beldame J, Boisrenoult P, Beaufils P. Pin track induced fractures around computer-assisted TKA. Orthop Traumatol Surg Res. 2010 May;96(3):249-55. doi: 10.1016/j.otsr.2009.12.005. Epub 2010 Apr 8.
Hoke D, Jafari SM, Orozco F, Ong A. Tibial shaft stress fractures resulting from placement of navigation tracker pins. J Arthroplasty. 2011 Apr;26(3):504.e5-8. doi: 10.1016/j.arth.2010.05.009.
Berning ET, Fowler RM. Thermal damage and tracker-pin track infection in computer-navigated total knee arthroplasty. J Arthroplasty. 2011 Sep;26(6):977.e21-4. doi: 10.1016/j.arth.2010.08.012. Epub 2010 Oct 14.
Gulhane S, Holloway I, Bartlett M. A vascular complication in computer navigated total knee arthroplasty. Indian J Orthop. 2013 Jan;47(1):98-100. doi: 10.4103/0019-5413.106927.
Keyes BJ, Markel DC, Meneghini RM. Evaluation of limb alignment, component positioning, and function in primary total knee arthroplasty using a pinless navigation technique compared with conventional methods. J Knee Surg. 2013 Apr;26(2):127-32. doi: 10.1055/s-0032-1319788. Epub 2012 Jul 13.
Chen JY, Chin PL, Tay DK, Chia SL, Lo NN, Yeo SJ. Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2014 Aug;22(8):1827-32. doi: 10.1007/s00167-013-2456-5. Epub 2013 Mar 2.
Chen JY, Chin PL, Li Z, Yew AK, Tay DK, Chia SL, Lo NN, Yeo SJ. Radiological outcomes of pinless navigation in total knee arthroplasty: a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc. 2015 Dec;23(12):3556-62. doi: 10.1007/s00167-014-3226-8. Epub 2014 Aug 14.
Licini DJ, Meneghini RM. Modern abbreviated computer navigation of the femur reduces blood loss in total knee arthroplasty. J Arthroplasty. 2015 Oct;30(10):1729-32. doi: 10.1016/j.arth.2015.04.020. Epub 2015 Apr 23.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CMRPG8J0311
Identifier Type: -
Identifier Source: org_study_id