Recruitment Status

NOT_YET_RECRUITING

Total Enrollment

5000 participants

Study Classification

OBSERVATIONAL

Study Start Date

2020-01-01

Study Completion Date

2031-12-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The objective of this study is to demonstrate the continued safety and efficacy in a real-world setting of transcatheter device closure of the PDA in premature infants less than 2kg in weight at the time of device implant using the Amplatzer Piccolo Occluder device and other devices performed in the USA.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Based on the IMPACT registry, there are over 6000 transcatheter device closures of PDA that occurs in the United States annually. However, there are no comprehensive data collection tools for this procedure. The current databases do not include multiple data points, or follow-up data, or a section for specific adverse events to be documented. Moreover, until now, there has been no approved devices for PDA closure in children \< 2kg. This clinical study is the first of its kind to collect data from all transcatheter device closure of PDA in children \< 2kg performed in the USA.This study will be limited to children between 700 to 2000 grams who are the most vulnerable population undergoing this procedure. This will allow us to understand the real world experience (efficacy and safety) of using the Amplatzer Piccolo Occluder and other devices in an extremely vulnerable, yet highly underserved population. The study will allow for standardization of this procedure throughout the country for the small children (\<2 kg) with a PDA. This is a multi-center, single arm, observational data collection study. This will be a large population study to help analyze outcomes in subjects \<2 kg. The trial has two primary endpoints for safety and effectiveness without formal hypothesis. The safety and effectiveness results will be compared with data reported in the ADO II AS IDE and Continued Access Protocol studies.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Ductus Arteriosus, Patent

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_ONLY

Study Time Perspective

OTHER

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Registry Group

All participants will have the same data collected at the same time points.

Transcatheter PDA Closure

Intervention Type DEVICE

Device utilized for closure of PDA, study is to help assure continued safety and effectiveness of FDA approved Amplatzer Piccolo Occluder device as well as other devices used off label for PDA closure in premature infants less than 2 kg at the time of device implant.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Transcatheter PDA Closure

Device utilized for closure of PDA, study is to help assure continued safety and effectiveness of FDA approved Amplatzer Piccolo Occluder device as well as other devices used off label for PDA closure in premature infants less than 2 kg at the time of device implant.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Diagnosis of PDA.
2. Clinical indication for transcatheter PDA closure (discretion of the physician).
3. Weight \<2 kg at the time of device implant.

Exclusion Criteria

1. Weight \<700 gm or greater than or equal to 2 kg at the time of device implant.
2. Age \< 3 days at the time of device implant.
3. Pre-existing coarctation of the aorta.
4. Pre-existing left pulmonary artery stenosis.
5. Cardiac output that is dependent on right to left shunt through the PDA due to pulmonary hypertension.
6. Intracardiac thrombus that interferes with device implant.
7. Active infection requiring treatment at the time of impant.
Minimum Eligible Age

3 Days

Maximum Eligible Age

1 Year

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Abbott

INDUSTRY

Sponsor Role collaborator

Le Bonheur Children's Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Shyam K. Sathanandam, MD

Associate Professor of Pediatrics, University of Tennessee. Director of Cath Lab, Le Bonheur Children's Hospital.

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Shyam Sathanandam, MD

Role: PRINCIPAL_INVESTIGATOR

National Principal Investigator

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

LeBonheur Children's Hospital

Memphis, Tennessee, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Shyam K Sathanandam, MD

Role: CONTACT

Phone: 901-287-6380

Email: [email protected]

Jorden Cunningham, BSN

Role: CONTACT

Phone: 901-287-7457

Email: [email protected]

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Shyam K Sathanandam, MD

Role: primary

Jorden Cunningham, BSN

Role: backup

References

Explore related publications, articles, or registry entries linked to this study.

Tashiro J, Perez EA, Sola JE. Reduced Hospital Mortality With Surgical Ligation of Patent Ductus Arteriosus in Premature, Extremely Low Birth Weight Infants: A Propensity Score-matched Outcome Study. Ann Surg. 2016 Mar;263(3):608-14. doi: 10.1097/SLA.0000000000001228.

Reference Type RESULT
PMID: 25822689 (View on PubMed)

Schneider DJ. The patent ductus arteriosus in term infants, children, and adults. Semin Perinatol. 2012 Apr;36(2):146-53. doi: 10.1053/j.semperi.2011.09.025.

Reference Type RESULT
PMID: 22414886 (View on PubMed)

Mahoney LT, Coryell KG, Lauer RM. The newborn transitional circulation: a two-dimensional Doppler echocardiographic study. J Am Coll Cardiol. 1985 Sep;6(3):623-9. doi: 10.1016/s0735-1097(85)80123-6.

Reference Type RESULT
PMID: 4031274 (View on PubMed)

Philip R, Waller BR 3rd, Agrawal V, Wright D, Arevalo A, Zurakowski D, Sathanandam S. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device. Catheter Cardiovasc Interv. 2016 Feb 1;87(2):310-7. doi: 10.1002/ccd.26287. Epub 2015 Nov 3.

Reference Type RESULT
PMID: 26525611 (View on PubMed)

Krichenko A, Benson LN, Burrows P, Moes CA, McLaughlin P, Freedom RM. Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol. 1989 Apr 1;63(12):877-80. doi: 10.1016/0002-9149(89)90064-7. No abstract available.

Reference Type RESULT
PMID: 2929450 (View on PubMed)

Pass RH. Amplatzer Duct Occluder device: a new technology for the closure of the moderate-to-large-sized patent ductus arteriosus. Expert Rev Med Devices. 2006 May;3(3):291-6. doi: 10.1586/17434440.3.3.291.

Reference Type RESULT
PMID: 16681450 (View on PubMed)

Moore JW, Levi DS, Moore SD, Schneider DJ, Berdjis F. Interventional treatment of patent ductus arteriosus in 2004. Catheter Cardiovasc Interv. 2005 Jan;64(1):91-101. doi: 10.1002/ccd.20243.

Reference Type RESULT
PMID: 15619281 (View on PubMed)

Perlo f, Joseph K.The Clinical Recognition of Congenital Heart Disease. Philadelphia: Saunders. Print.

Reference Type RESULT

Gross RE, Hubbard JP. Landmark article Feb 25, 1939: Surgical ligation of a patent ductus arteriosus. Report of first successful case. By Robert E. Gross and John P. Hubbard. JAMA. 1984 Mar 2;251(9):1201-2. doi: 10.1001/jama.251.9.1201. No abstract available.

Reference Type RESULT
PMID: 6363741 (View on PubMed)

Kabra NS, Schmidt B, Roberts RS, Doyle LW, Papile L, Fanaroff A; Trial of Indomethacin Prophylaxis in Preterms Investigators. Neurosensory impairment after surgical closure of patent ductus arteriosus in extremely low birth weight infants: results from the Trial of Indomethacin Prophylaxis in Preterms. J Pediatr. 2007 Mar;150(3):229-34, 234.e1. doi: 10.1016/j.jpeds.2006.11.039.

Reference Type RESULT
PMID: 17307535 (View on PubMed)

Chorne N, Leonard C, Piecuch R, Clyman RI. Patent ductus arteriosus and its treatment as risk factors for neonatal and neurodevelopmental morbidity. Pediatrics. 2007 Jun;119(6):1165-74. doi: 10.1542/peds.2006-3124.

Reference Type RESULT
PMID: 17545385 (View on PubMed)

Teixeira LS, Shivananda SP, Stephens D, Van Arsdell G, McNamara PJ. Postoperative cardiorespiratory instability following ligation of the preterm ductus arteriosus is related to early need for intervention. J Perinatol. 2008 Dec;28(12):803-10. doi: 10.1038/jp.2008.101. Epub 2008 Jul 10.

Reference Type RESULT
PMID: 18615091 (View on PubMed)

Porstmann W, Wierny L, Warnke H, Gerstberger G, Romaniuk PA. Catheter closure of patent ductus arteriosus. 62 cases treated without thoracotomy. Radiol Clin North Am. 1971 Aug;9(2):203-18. No abstract available.

Reference Type RESULT
PMID: 4938290 (View on PubMed)

Weisz DE, McNamara PJ. Patent ductus arteriosus ligation and adverse outcomes: causality or bias? J Clin Neonatol. 2014 Apr;3(2):67-75. doi: 10.4103/2249-4847.134670.

Reference Type RESULT
PMID: 25024972 (View on PubMed)

Gruenstein DH, Ebeid M, Radtke W, Moore P, Holzer R, Justino H. Transcatheter closure of patent ductus arteriosus using the AMPLATZER duct occluder II (ADO II). Catheter Cardiovasc Interv. 2017 May;89(6):1118-1128. doi: 10.1002/ccd.26968. Epub 2017 Mar 4.

Reference Type RESULT
PMID: 28258658 (View on PubMed)

Kenny D, Morgan GJ, Bentham JR, Wilson N, Martin R, Tometzki A, Oslizlok P, Walsh KP. Early clinical experience with a modified Amplatzer ductal occluder for transcatheter arterial duct occlusion in infants and small children. Catheter Cardiovasc Interv. 2013 Oct 1;82(4):534-40. doi: 10.1002/ccd.24522. Epub 2013 Jun 29.

Reference Type RESULT
PMID: 22718329 (View on PubMed)

Sungur M, Karakurt C, Ozbarlas N, Baspinar O. Closure of patent ductus arteriosus in children, small infants, and premature babies with Amplatzer duct occluder II additional sizes: multicenter study. Catheter Cardiovasc Interv. 2013 Aug 1;82(2):245-52. doi: 10.1002/ccd.24905. Epub 2013 Apr 8.

Reference Type RESULT
PMID: 23460349 (View on PubMed)

Bruckheimer E, Godfrey M, Dagan T, Levinzon M, Amir G, Birk E. The Amplatzer Duct Occluder II Additional Sizes device for transcatheter PDA closure: initial experience. Catheter Cardiovasc Interv. 2014 Jun 1;83(7):1097-101. doi: 10.1002/ccd.25445. Epub 2014 Mar 4.

Reference Type RESULT
PMID: 24532416 (View on PubMed)

Baspinar O, Sahin DA, Sulu A, Irdem A, Gokaslan G, Sivasli E, Kilinc M. Transcatheter closure of patent ductus arteriosus in under 6 kg and premature infants. J Interv Cardiol. 2015 Apr;28(2):180-9. doi: 10.1111/joic.12196. Epub 2015 Apr 2.

Reference Type RESULT
PMID: 25832591 (View on PubMed)

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

The U.S. PDA Registry

Identifier Type: -

Identifier Source: org_study_id