Virtual Reality Test of Strabismus

NCT ID: NCT04156763

Last Updated: 2023-12-22

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

TERMINATED

Total Enrollment

19 participants

Study Classification

OBSERVATIONAL

Study Start Date

2020-06-22

Study Completion Date

2022-06-08

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Strabismus, or squint, describes any misalignment of the eyes, and can affect both children and adults. As a result, the images of the outside world conveyed to the brain from the two eyes do not correspond, which can result in diplopia, or 'double vision'. As well as impacting on a patient's functionality, strabismus can have cosmetic and psychosocial ramifications. Furthermore, if left untreated in childhood, strabismus can lead to life-long visual impairment, despite best spectacle correction.

Current treatment is guided by the exact nature of the strabismus and the patient's age; options include spectacle prescription to correct underlying refractive error, use of prisms to control deviation, or in certain cases, surgery. In order to investigate the size and type of strabismus present, and determine the best management, tests of ocular deviation are performed in Eye Clinics.

Quantitative objective assessment of the angle of horizontal and vertical strabismus is currently performed using the prism cover test - the patient is asked to look at a fixation target, and prisms of increasing power are placed in front of one eye until the ocular deviation is neutralised (i.e. there is no movement of the eyes to take up fixation). The test can provide accurate numerical recordings to aid in monitoring and surgical planning.

However, the prism cover test requires a range of different prisms, the presence of a near and distance fixation target, a trained examiner, and a patient able to fixate at an appropriate target without moving their head for the duration of the test. In this study, it will be investigated whether a virtual reality headset-based test can produce comparable measurements of ocular deviation to the traditional prism cover test, without the need for prisms, or control of head posture.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Purpose

1. To establish whether a virtual reality headset-based test can produce accurate and reliable data on ocular deviation in those with disturbances of ocular motility, by comparing its performance to those of established tests of ocular deviation currently in use in clinical practice (prism cover test).
2. To assess the practicality, and subjective experience of a virtual reality headset- based Lancaster red-green test, using questionnaire surveys

Background

Strabismus, or squint, describes any misalignment of the eyes, and can affect both children and adults. As a result, the images of the outside world conveyed to the brain from the two eyes do not correspond, which can result in diplopia, or 'double vision'. As well as impacting on a patient's functionality, strabismus can have cosmetic and psychosocial ramifications. Furthermore, if left untreated in childhood, strabismus can lead to life-long visual impairment, despite best spectacle correction.

Current treatment is guided by the exact nature of the strabismus and the patient's age; options include spectacle prescription to correct underlying refractive error, use of prisms to control deviation, or in certain cases, surgery. In order to investigate the size and type of strabismus present, and determine the best management, tests of ocular deviation are performed in Eye Clinics.

Quantitative objective assessment of the angle of horizontal and vertical strabismus is currently performed using the prism cover test - the patient is asked to look at a fixation target, and prisms of increasing power are placed in front of one eye until the ocular deviation is neutralised (i.e. there is no movement of the eyes to take up fixation). The test can provide accurate numerical recordings to aid in monitoring and surgical planning.

However, the prism cover test requires a range of different prisms, the presence of a near and distance fixation target, a trained examiner, and a patient able to fixate at an appropriate target without moving their head for the duration of the test. In this study, it will be investigated whether a virtual reality headset-based test can produce comparable measurements of ocular deviation to the traditional prism cover test, without the need for prisms, or control of head posture.

Design and Methodology

Research participants will be recruited from the pool of patients presenting to the Eye department for their regular appointment.

Those who meet the inclusion criteria will have the study explained to them by a member of the research team in the department, and given a leaflet to read about the study. Should they wish to take part, they will have verbal and written consent taken, and then undergo two tests:

1. Prism cover test
2. Virtual reality headset-based test

Each test will last approximately 10 minutes. At the end of the two tests, they will be asked to fill in a questionnaire on their experience of the tests. They will require no additional visits to clinic as part of enrolling in the study.

Statistical Analysis

The angles of deviation of the eyes will be extracted from each of the three tests, and Bland Altman analysis will be applied to the data to check for agreement.

The subjective experience of the virtual reality headset-based Lancaster red-green test measured by the questionnaire, and compared to the subjective experience of the two established tests of ocular deviation using a paired t-test.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Strabismus

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Strabismus Virtual Reality Prism Cover Test

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_ONLY

Study Time Perspective

CROSS_SECTIONAL

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

• Patients with restrictive and paretic disturbances of ocular motility

Exclusion Criteria

* Patients without capacity to consent
* Patients unwilling to participate
* Patients aged under 18
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Julie Dawson

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Julie Dawson

Research Services Manager

Responsibility Role SPONSOR_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Norfolk & Norwich University Hospitals NHS Foundation Trust

Norwich, Norfolk, United Kingdom

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United Kingdom

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

268329 (100-06-19)

Identifier Type: -

Identifier Source: org_study_id