VasQ and Hemodynamic Conditions in AVFs

NCT ID: NCT04141852

Last Updated: 2021-11-26

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

6 participants

Study Classification

INTERVENTIONAL

Study Start Date

2019-10-11

Study Completion Date

2021-07-22

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

End-stage renal disease (ESRD) is a growing global health problem, strictly connected with progressive ageing population and longer survival of patients living on renal replacement therapy. The majority of ESRD patients is on hemodialysis (HD) treatment. A successful HD procedure requires a functional vascular access (VA) to provide safe and long-lasting way to connect patient circulation to the artificial kidney. To date, VA dysfunction is the major cause of morbidity and hospitalisation in HD patients, and the major limitation of HD treatment. The current recommendation for VA is the native artero-venous fistula (AVF), surgically created in the forearm, but is still affected by high non-maturation and early failure rates. The most common cause of AVF early-failure is vascular stenosis due to neointimal hyperplasia (NH). Despite the exact mechanisms underlying stenosis development remain tentative, there is general consensus that hemodynamic conditions play a key role in the formation of NH. Previous computational fluid dynamics (CFD) investigations inside patient-specific AVF models conducted by our group revealed transitional laminar-to-turbulent flow in the juxta-anastomotic vein.

Various vascular access devices have been designed to incorporate features to regularize the hemodynamics and favour spiral flow development in the venous segment of the AVF. The VasQ external support device (Laminate Medical Technologies, Israel) is a novel Nitinol implant, externally surrounding and supporting the vein and "hugging" the artery near the junction site, without being in contact with the blood flow.

VasQ attempts at constraining and shaping geometrical parameters of the AVF, as well as reinforcing the vulnerable perianastomotic vein against high pressure, wall tension and flow levels. A prospective single-centre study demonstrated the safety of the VasQ external support device, but the effect of its use on hemodynamic conditions and the advantages in terms of flow regularization in patient-specific AVFs still need to be investigated.

A detailed analysis of the local blood flow field in patient-specific AVFs can be obtained coupling non contrast-enhanced MRI (NCE-MRI) and high-resolution CFD simulations, using a NCE-MRI protocol recently optimized by our group. Our MRI sequence has the advantage of providing high-quality images in a short acquisition time of 5-10 minutes compared to other MRI protocols that require more than 45 minutes for a single acquisition. Combined with high-resolution CFD, our MRI-to-CFD pipeline allowed us to characterize morphological and hemodynamic changes in the AVF of one patient at two timepoints, immediately after AVF surgery and at AVF maturation. Therefore, it seems to be a promising approach to perform morphological and hemodynamic analysis also in AVF created using the VasQ device and can be used to elucidate the effects of VasQ device on hemodynamic conditions, as compared to hemodynamic conditions present in AVFs created using conventional surgery without the use of any device.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Renal Insufficiency, Chronic

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

artero-venous fistula non-Contrast Enhanced MRI hemodynamics CFD simulations VasQ

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

DEVICE_FEASIBILITY

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

AVF surgery with device

Group Type EXPERIMENTAL

Implantation of VasQ device

Intervention Type DEVICE

The VasQ external support device (Laminate Medical Technologies, Israel) is a novel Nitinol implant, externally surrounding and supporting the vein and "hugging" the artery near the junction site, without being in contact with the blood flow.

AVF surgery conventional

Group Type NO_INTERVENTION

No interventions assigned to this group

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Implantation of VasQ device

The VasQ external support device (Laminate Medical Technologies, Israel) is a novel Nitinol implant, externally surrounding and supporting the vein and "hugging" the artery near the junction site, without being in contact with the blood flow.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Age \> 18 years and \< 75 years
2. Patients that entered the pre-dialysis program because of ESRD
3. Patients in need of a new VA for HD treatment
4. Treatment of first choice is creation of a distal autogenous AVF
5. Written informed consent

Exclusion Criteria

1. Contraindication for creating an autogenous AVF
2. Life expectancy less than 1 year
3. Prior VA, central venous stenosis or obstructions in the arm selected for AVF surgery
4. Patient not suitable for MRI examination (ferro-magnetic prosthesis, pacemaker, aneurysm clips, obesity, spastic paralysis, severe claustrophobia or other contraindications or exclusions interfering with MRI)
5. Unusual anatomy or vessel dimensions (observed on pre-operative US or intraoperatively) and which preclude adequate fit of the VasQ.
6. Depth of vein greater than 8 mm (on ultrasound) on side of surgery
7. Known coagulation disorder
8. Known allergy to nitinol
9. Patients expected to undergo kidney transplant within 12 months of enrollment
10. Females who are pregnant or planning to become pregnant during the study
11. Inability to give consent and/or comply with the study follow up schedule
Minimum Eligible Age

18 Years

Maximum Eligible Age

75 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Laminate Medical Technologies

INDUSTRY

Sponsor Role collaborator

Mario Negri Institute for Pharmacological Research

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

ASST - Papa Giovanni XXIII - U.O. Nefrologia e Dialisi/ Mario Negri Institute for Pharmacological Research - Clinical Research Center for Rare Diseases Aldo e Cele Daccò

Bergamo, BG, Italy

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Italy

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

RESHAPE

Identifier Type: -

Identifier Source: org_study_id