Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
NCT ID: NCT04136613
Last Updated: 2020-01-18
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
150 participants
INTERVENTIONAL
2015-09-01
2019-06-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The less use of family planning methods, the higher the fertility rate and the less interpregnancy interval which will carry an obvious more risk to the mother and the fetus especially if the cesarean delivery rate shown an increase trend as the case in Iraq. For that reason, contraception needs to be practiced in this critical period and an intrauterine contraceptive device ( IUD), the most commonly used reversible method of contraception worldwide could be an excellent choice during this period.
There were few evidences available about the safety and feasibility on practicing this type of contraception when we did start three years ago and no previous evidences in Iraq about practicing this method at the immediate postpartum period.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison Between Intrauterine Contraceptive Device Insertion During Cesarean Section Vs Conventional Application
NCT02674139
Post-placental Intrauterine Device Insertion During Cesarean Section
NCT03780985
Safety and Efficacy of Immediate Post Placental IUD Insertion in Patients Undergoing Cesarean Delivery
NCT04630548
Intra-cesarean Post Placental Introducer Withdrawal IUD Insertion Technique
NCT05788354
Immediate Post-placental Insertion of IUCD During Cesarean Delivery Versus 6 Week Post-Cesarean Insertion
NCT03404622
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
It is a single arm prospective clinical trial. That had been conducted at Al Elweyia Maternity Teaching Hospital and Al Hayat Private Hospital in Baghdad during the period from Sept., 1st, 2015 to Jan.,1st, 2019. Women delivering in those hospitals fulfilling inclusion criteria were included in the study after obtaining informed consent. The study protocol was approved by the ethical committee.
Data collection:
180 women were enrolled in the study, only 150 of them completed the study as thirty women we couldn't reach them through their contact numbers.
Intervention:
They had immediate post-partum insertion of Copper IUD (Cu-T 380A) after delivery of placenta immediately at cesarean delivery. To overcome the considerable expulsion rate in the previous studies, we stabilize the IUD in place at the uterine fundus by an absorbable suture; vicryl 0 that was introduced through the fundus ( from out to in), held the needle with sponge holder that was introduce up the fundus and taken out the vicryl through the lower uterine incision, cutting the needle, warped the vicryl around the the T arm of the IUD and withdrawn back to be placed inside the uterine cavity near the fundus. Before closing the uterine incision, the threads were placed in the lower uterine segment, then the uterine incision was closed routinely.
Follow up:
Women were assessed before discharge from the hospital looking for any excessive bleeding and were provided with a mobile number to call, in case she has any problem with the device that had been inserted.
Women were reassessed at six weeks postpartum, where speculum examination was done and if IUD threads was seen, they were trimmed at 2 cm from external os, otherwise if the threads of IUD were not seen a pelvic ultrasonography was done to confirm the presence of IUD in situ.
Women then were reassessed at yearly intervals for 3 years, looking for the occurrence of excessive bleeding during subsequent menstruation, for abdominal pain and abnormal vaginal discharge, missed threads, expulsion rate, continuation rate and how far they do recommend this method of contraception for other women.
Statistical analysis:
The data analyzed using Statistical Package for Social Sciences (SPSS) version 25. The data presented as mean, standard deviation and ranges. Categorical data presented by frequencies and percentages. Chi square test was used to assess the association between complication of IUD and certain information. Significance level was set at P \< 0.05.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Post placental intra uterine device insertion
There was immediate post-partum insertion of CuT 380 A intrauterine device after delivery of placenta during cesarean delivery. To overcome the considerable expulsion rate in the previous studies, we stabilize the IUD in place at the fundus be an absorbable suture; vicryl 0 that was introduced through the fundus, held the needle with sponge holder that was introduce up the fundus and taken out the vicryl through the lower uterine inscion, cutting the needle, hold the vicryl around the the T arm of the IUD and withdrawn back to be placed inside the fundus. Before closing the uterine incision, the threads were placed in the lower uterine segment, then the uterine incision was then closed routinely.
Copper Intra uterine contarceptive device ( Cu-T 380A)
Insertion of the Cu-T 380A during cesarean delivery immediately after placental removal.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Copper Intra uterine contarceptive device ( Cu-T 380A)
Insertion of the Cu-T 380A during cesarean delivery immediately after placental removal.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Uterine anomaly that was known to distort the uterine cavity; whether uterine fibroid or congenital uterine anomalies.
* Developed postpartum hemorrhage.
* Diagnosed chorioamnionitis, intrapartum fever, or ruptured membranes for greater than 24 hours prior to delivery.
* Placenta previa or accrete.
* Anemia during pregnancy (Hb \< 10 g/dl).
18 Years
45 Years
FEMALE
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Elweyia Maternity Teaching Hospital
OTHER
Taghreed Alhaidari
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Taghreed Alhaidari
Assistant Professor/ Consultant Obstatricain & Gynecologist / Head of Scientific Affairs Unit
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Taghreed K Alhaidari, CABOG
Role: STUDY_CHAIR
Al Kindy College of Medicine, University of Baghdad
Taghreed K Alhaidari, CABOG
Role: PRINCIPAL_INVESTIGATOR
Al Kindy College of Medicine, University of Baghdad
Asmaa T Majeed, FICOG
Role: PRINCIPAL_INVESTIGATOR
Al Kindy College of Medicine, University of Baghdad
Sahar J Al-Jassani, CABOG
Role: PRINCIPAL_INVESTIGATOR
Al Kindy College of Medicine, University of Baghdad
Hayder A Fawzi, FICMS
Role: PRINCIPAL_INVESTIGATOR
Department of Pharmacy, Al-Esraa University College
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Al Kindy College of Medicine/ University of Baghdad
Baghdad, , Iraq
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
9 Al-KindyCM
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.