Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
67 participants
INTERVENTIONAL
2007-08-01
2010-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
As to short-term pad test, previous studies had some concerned about the reliability and reproducibility. Thus, undertaking our previous two studies, we want to evaluate the test-retest reliability of the 20-minute pad test infused with SD amount of water in bladder in women with SUI.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
A multichannel urodynamic equipment (Life-Tech, Houston, TX, USA) with computer analysis and Urovision (Urolab Janus System V, Houston, Tex) was used. All terminology conformed to the standards recommended by the ICS and Urodynamic Society. All procedures were performed by an experienced technician, and the data were interpreted by a single observer to avoid inter-observer variability.
STATA software (Version 11.0; Stata Corp, College Station, TX, USA) was used for statistical analyses. Spearman rank-correlation coefficient and intraclass correlation coefficient were tested for correlation and reliability of the test and retest results. The Wilcoxon signed rank test was tested for the difference of the test and retest. A p value of less than 0.05 was considered statistically significant.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Study population
Women who had fulfilled the standardization of terminology of lower urinary function from ICS were diagnosed as urodynamic stress incontinence (USI) after urodynamic study (UDS) and enrolled for analysis in this study.
20-minute pad test
Our 20-minute modified pad test was described previously proposed first by Hahn and Fall and modified by Sand and Ostergard. Each patient's bladder was emptied with a transurethral catheter and filled to the SD amount of sterile water for test. The catheter was removed, and then the patient returned to a standing position with a pre-weighed perineal pad placed on the underwear. The patient was asked to cough 10 times, bear down 10 times, do 10 deep knee bends, jump up and down on the spot 10 times, wash her hands under cold water for 1 minute, walk up and down five stairs 10 times, walk in the hall for 10 minute, and then return for removal of the pad. The pad was then weighed and the net weight was calculated by subtracting from the original dry weight to achieve a measure of the total urine loss during the 20 minute exercise. The pad weight was measured in grams and the accuracy of the scale was 1 gram. The positive pad weight result was defined as more than 1 gram of leakage.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
20-minute pad test
Our 20-minute modified pad test was described previously proposed first by Hahn and Fall and modified by Sand and Ostergard. Each patient's bladder was emptied with a transurethral catheter and filled to the SD amount of sterile water for test. The catheter was removed, and then the patient returned to a standing position with a pre-weighed perineal pad placed on the underwear. The patient was asked to cough 10 times, bear down 10 times, do 10 deep knee bends, jump up and down on the spot 10 times, wash her hands under cold water for 1 minute, walk up and down five stairs 10 times, walk in the hall for 10 minute, and then return for removal of the pad. The pad was then weighed and the net weight was calculated by subtracting from the original dry weight to achieve a measure of the total urine loss during the 20 minute exercise. The pad weight was measured in grams and the accuracy of the scale was 1 gram. The positive pad weight result was defined as more than 1 gram of leakage.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Urinary tract infection
* Pelvic inflammation or malignancy
* Long term urinary catheterization
20 Years
85 Years
FEMALE
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
National Taiwan University Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Ho-Hsiung Lin, PhD
Role: PRINCIPAL_INVESTIGATOR
National Taiwan University Hospital
References
Explore related publications, articles, or registry entries linked to this study.
Sutherst J, Brown M, Shawer M. Assessing the severity of urinary incontinence in women by weighing perineal pads. Lancet. 1981 May 23;1(8230):1128-30. doi: 10.1016/s0140-6736(81)92299-6.
Abrams P, Blaivas JG, Stanton SL, Andersen JT. The standardisation of terminology of lower urinary tract function. The International Continence Society Committee on Standardisation of Terminology. Scand J Urol Nephrol Suppl. 1988;114:5-19. No abstract available.
Abrams P, Cardozo L, Fall M, Griffiths D, Rosier P, Ulmsten U, van Kerrebroeck P, Victor A, Wein A; Standardisation Sub-committee of the International Continence Society. The standardisation of terminology of lower urinary tract function: report from the Standardisation Sub-committee of the International Continence Society. Neurourol Urodyn. 2002;21(2):167-78. doi: 10.1002/nau.10052. No abstract available.
Ferreira CH, Bo K. The Pad Test for urinary incontinence in women. J Physiother. 2015 Apr;61(2):98. doi: 10.1016/j.jphys.2014.12.001. Epub 2015 Mar 3. No abstract available.
Wu WY, Sheu BC, Lin HH. Comparison of 20-minute pad test versus 1-hour pad test in women with stress urinary incontinence. Urology. 2006 Oct;68(4):764-8. doi: 10.1016/j.urology.2006.04.018.
Krhut J, Zachoval R, Smith PP, Rosier PF, Valansky L, Martan A, Zvara P. Pad weight testing in the evaluation of urinary incontinence. Neurourol Urodyn. 2014 Jun;33(5):507-10. doi: 10.1002/nau.22436. Epub 2013 Jun 24.
Lose G, Rosenkilde P, Gammelgaard J, Schroeder T. Pad-weighing test performed with standardized bladder volume. Urology. 1988 Jul;32(1):78-80. doi: 10.1016/0090-4295(88)90462-1.
Wu WY, Sheu BC, Lin HH. Twenty-minute pad test: comparison of infusion of 250 ml of water with strong-desire amount in the bladder in women with stress urinary incontinence. Eur J Obstet Gynecol Reprod Biol. 2008 Jan;136(1):121-5. doi: 10.1016/j.ejogrb.2007.02.030. Epub 2007 May 30.
Simons AM, Yoong WC, Buckland S, Moore KH. Inadequate repeatability of the one-hour pad test: the need for a new incontinence outcome measure. BJOG. 2001 Mar;108(3):315-9. doi: 10.1111/j.1471-0528.2001.00069.x.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
200612063R
Identifier Type: -
Identifier Source: org_study_id