Trial Outcomes & Findings for Replaceability of Fluoroscopy and Ultrasound in the Evaluation of Hemidiaphragm Excursion (NCT NCT04098939)
NCT ID: NCT04098939
Last Updated: 2024-12-12
Results Overview
Movement of diaphragm measured with ultrasound Ultrasound measures: Diaphragm excursion in centimeters with M-mode.
Recruitment status
COMPLETED
Target enrollment
42 participants
Primary outcome timeframe
during intervention, up to 1 hour
Results posted on
2024-12-12
Participant Flow
Participant milestones
| Measure |
Participants
Participants undergoing ultrasound and fluoroscopy assessment of diaphragm excursion.
Diaphragm evaluation: Ultrasound and radiographic evaluation of diaphragm function
|
|---|---|
|
Overall Study
STARTED
|
42
|
|
Overall Study
COMPLETED
|
42
|
|
Overall Study
NOT COMPLETED
|
0
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Replaceability of Fluoroscopy and Ultrasound in the Evaluation of Hemidiaphragm Excursion
Baseline characteristics by cohort
| Measure |
Participants
n=42 Participants
Participants undergoing ultrasound and fluoroscopy assessment of diaphragm excursion.
Diaphragm evaluation: Ultrasound and radiographic evaluation of diaphragm function
|
|---|---|
|
Age, Continuous
|
59.7 years
STANDARD_DEVIATION 13.3 • n=5 Participants
|
|
Sex: Female, Male
Female
|
15 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
27 Participants
n=5 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Asian
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Black or African American
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
White
|
42 Participants
n=5 Participants
|
|
Race (NIH/OMB)
More than one race
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
|
Height, cm
|
176.7 Centimeters
STANDARD_DEVIATION 10.8 • n=5 Participants
|
|
Weight. Kg
|
81.9 kilograms
STANDARD_DEVIATION 17.4 • n=5 Participants
|
PRIMARY outcome
Timeframe: during intervention, up to 1 hourMovement of diaphragm measured with ultrasound Ultrasound measures: Diaphragm excursion in centimeters with M-mode.
Outcome measures
| Measure |
Participants
n=42 Participants
Participants undergoing ultrasound and fluoroscopy assessment of diaphragm excursion.
Diaphragm evaluation: Ultrasound and radiographic evaluation of diaphragm function
|
|---|---|
|
Diaphragm Function
|
4.25 centimeters
Standard Deviation 2.05
|
Adverse Events
Participants
Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place