Use of the SonoSite Probe for Measuring Jugular Venous Pressure

NCT ID: NCT03815188

Last Updated: 2019-10-31

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

124 participants

Study Classification

OBSERVATIONAL

Study Start Date

2019-02-15

Study Completion Date

2019-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This prospective study will be performed in the Cardiothoracic (Chesterman) Department at Sheffield Teaching Hospitals NHSFT, Northern General Hospital. Pre-operative patients undergoing surgical valvular intervention, breathing both spontaneously and mechanically will be included in the trial. All patients will already have a central venous catheter inserted as part of their ongoing care. Patients will be eligible for the study irrespective of diagnosis or neck size. Patient demographical data will be recorded by Sam Jenkins following written consent, the day before the trial.

The goal of this study is to determine if ultrasound assessment of Jugular Venous Pressure (JVP) accurately predicts Central Venous Pressure (CVP). Secondary objectives aim to identify if using the angle of Louis to approximate the location of the right atrium produces inaccuracies when measuring JVP. Comparing results in patients breathing spontaneously or under positive pressure ventilation will identify if the form of ventilation impacts on JVP and CVP recording. Correlating results between physical JVP examination and ultrasound assessment of JVP to measure CVP will conclude if ultrasound is a more appropriate tool, in an era where the physical examination of the cardiovascular system is becoming less valuable.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Initial exploratory investigations will compare left-sided and right-sided Jugular Venous Pressure (JVP) using ultrasonography. Should results show that they are the same, the central line is to be placed into the right internal jugular vein when required.

To begin the trial and whilst the patient is spontaneously breathing, a physical examination of the right JVP will be performed. A central line will be inserted with the patient awake into the right internal jugular vein. Left-sided ultrasound of JVP and Central Venous Pressure (CVP) will be measured using the right-sided catheter will be recorded simultaneously. The tip of the catheter attached to the transducer (which is zeroed to the reference point) will be placed at the point of venous collapse, identified by ultrasonography, to identify if the JVP and CVP match. The tip of the catheter will then be placed at the angle of Louis. Measurement of the pressure difference between the angle of Louis and the reference point will identify if this value shows variability compared to previous approximations of 5cm above the right atrium. With the patient anaesthetised and mechanically breathing, left JVP and CVP will be measured once more. Twenty-four hours post-surgery, ultrasound of the JVP and CVP will be measured with the patient breathing spontaneously.

The physical JVP examination will be recorded from the opposite side to the central venous catheter. The bed will be adjusted to an angle between 30 and 60 degrees, that most clearly identifies the collapsing vein. Differentiation between the JVP and the carotid pulse must be distinguished. Tangential lighting using a flashlight should be used to correctly identify and note the apex of the jugular venous pulsations. Recordings will be taken at end-expiration allowing the vertical distance between the venous meniscus and phlebostatic axis to be measured. JVP will be measured in millimetres of water.

Ultrasound recordings will be made using the SonoSite ultrasound probe by Sam Jenkins. The equipment and gels required are used routinely on site and will be supplied by Sheffield Teaching Hospitals. The SonoSite probe will be calibrated prior to each use, based on the recommendations of the manufacturer. The angle of the bed is kept constant and the patient will remain in the same position following the physical JVP examination. Ultrasound gel will be applied, again on the opposite side to the central venous catheter. Locating the area of venous collapse will be identified following visualisation from both longitudinal and transverse planes. The apex of venous collapse at end-expiration will be marked using the longitudinal view. Corroboration of the correct position of the probe by looking at the transverse view will be performed prior to marking of venous collapse.

CVP will be measured once the central venous catheter has been zeroed. The reference point of the transducer will be placed at the 4th intercostal space, mid-axillary line. The bed should still be kept at a constant angle for this measurement. The mean of the 'a' wave upon end-expiration will be taken. Converting the CVP from millimetres of mercury to millimetres of water will allow direct comparison to prior findings of JVP.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Aortic Valve Surgery

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

RETROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Heart Valve Surgery

Pre-operative patients undergoing heart valve surgery will be selected and data recorded from each patient on the day of their surgery. This patient cohort is required in order to be able to accurately measure their JVP upon physical examination. Patients must have a central line inserted as part of their ongoing clinical management.

No interventions assigned to this group

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients undergoing cardiac surgery
* Patients who have a central line inserted during surgery
* Patients able and willing to give consent in verbal and written English.

Exclusion Criteria

* Patients under the age of 18
* Patients unable to provide consent in verbal and written English
* Patients with thyroid enlargement or alternative reason causing obstruction to venous anatomy
* Patients with significant tricuspid regurgitation
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Sheffield

OTHER

Sponsor Role collaborator

Sheffield Teaching Hospitals NHS Foundation Trust

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Sheffield Teaching Hospitals NHS FT

Sheffield, England, United Kingdom

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United Kingdom

References

Explore related publications, articles, or registry entries linked to this study.

Brennan JM, Blair JE, Goonewardena S, Ronan A, Shah D, Vasaiwala S, Brooks E, Levy A, Kirkpatrick JN, Spencer KT. A comparison by medicine residents of physical examination versus hand-carried ultrasound for estimation of right atrial pressure. Am J Cardiol. 2007 Jun 1;99(11):1614-6. doi: 10.1016/j.amjcard.2007.01.037. Epub 2007 Apr 18.

Reference Type BACKGROUND
PMID: 17531592 (View on PubMed)

Cook DJ, Simel DL. The Rational Clinical Examination. Does this patient have abnormal central venous pressure? JAMA. 1996 Feb 28;275(8):630-4. No abstract available.

Reference Type BACKGROUND
PMID: 8594245 (View on PubMed)

Deol GR, Collett N, Ashby A, Schmidt GA. Ultrasound accurately reflects the jugular venous examination but underestimates central venous pressure. Chest. 2011 Jan;139(1):95-100. doi: 10.1378/chest.10-1301. Epub 2010 Aug 26.

Reference Type BACKGROUND
PMID: 20798190 (View on PubMed)

Fletcher RH, Fletcher SW. Has medicine outgrown physical diagnosis? Ann Intern Med. 1992 Nov 1;117(9):786-7. doi: 10.7326/0003-4819-117-9-786. No abstract available.

Reference Type BACKGROUND
PMID: 1416582 (View on PubMed)

Jang T, Aubin C, Naunheim R, Char D. Ultrasonography of the internal jugular vein in patients with dyspnea without jugular venous distention on physical examination. Ann Emerg Med. 2004 Aug;44(2):160-8. doi: 10.1016/j.annemergmed.2004.03.014.

Reference Type BACKGROUND
PMID: 15278091 (View on PubMed)

Lipton B. Estimation of central venous pressure by ultrasound of the internal jugular vein. Am J Emerg Med. 2000 Jul;18(4):432-4. doi: 10.1053/ajem.2000.7335.

Reference Type BACKGROUND
PMID: 10919533 (View on PubMed)

Mangione S, Nieman LZ. Cardiac auscultatory skills of internal medicine and family practice trainees. A comparison of diagnostic proficiency. JAMA. 1997 Sep 3;278(9):717-22.

Reference Type BACKGROUND
PMID: 9286830 (View on PubMed)

Seth R, Magner P, Matzinger F, van Walraven C. How far is the sternal angle from the mid-right atrium? J Gen Intern Med. 2002 Nov;17(11):852-6. doi: 10.1046/j.1525-1497.2002.20101.x.

Reference Type BACKGROUND
PMID: 12406357 (View on PubMed)

Socransky SJ, Wiss R, Robins R, Anawati A, Roy MA, Yeung IC. Defining normal jugular venous pressure with ultrasonography. CJEM. 2010 Jul;12(4):320-4. doi: 10.1017/s1481803500012409.

Reference Type BACKGROUND
PMID: 20650024 (View on PubMed)

Sondergaard S, Parkin G, Aneman A. Central venous pressure: we need to bring clinical use into physiological context. Acta Anaesthesiol Scand. 2015 May;59(5):552-60. doi: 10.1111/aas.12490. Epub 2015 Feb 13.

Reference Type BACKGROUND
PMID: 25684176 (View on PubMed)

Jenkins S, Knowles P, Briffa N. Portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease. J Ultrasound. 2022 Dec;25(4):939-947. doi: 10.1007/s40477-022-00654-7. Epub 2022 Mar 15.

Reference Type DERIVED
PMID: 35292924 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

STH20529

Identifier Type: -

Identifier Source: org_study_id