Supraclavicular Fossa US View for Catheter Positioning in Right Subclavian Central Venous Catheterization
NCT ID: NCT03812757
Last Updated: 2020-11-03
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
100 participants
OBSERVATIONAL
2019-01-18
2020-01-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Weber et al has described the use of the right supraclavicular fossa view for real-time ultrasound-guided placement of a central venous catheter (CVC) via the right internal jugular vein (IJV) in adults. This approach has subsequently been validated in a clinical study and has also been used for supraclavicular subclavian line insertion. The approach requires use of a microconvex probe, which couples good image resolution and high scanning depth. The use of a microconvex probe for infraclavicular subclavian central venous catheter (CVC) insertion has been described previously, but this is the first description of the supraclavicular fossa ultrasound view to guide correct catheter tip placement in infraclavicular right subclavian CVC placement.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Supraclavicular fossa US scanning
Following insertion of at least 20 cm of the guidewire into the right subclavian vein, the probe is shifted to the right supraclavicular fossa to scan the right internal jugular vein in order to exclude malposition of the guidewire. The probe is then tilted in a caudal direction to obtain a view of the guidewire within the superior vena cava. Misplaced guidewires will be corrected under real-time ultrasound guidance.
Supraclavicular fossa US scanning
As previously stated.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Supraclavicular fossa US scanning
As previously stated.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Subclavian vein catheterization deemed inappropriate by the operator,
* Central line/pacemaker/similar device already in place (risk for misinterpretation of the ultrasound image)
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Skane University Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Ola Borgquist
Principal investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Ola Borgquist, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
Skane University Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Skånes universitetssjukhus
Lund, , Sweden
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Adrian M, Kander T, Lunden R, Borgquist O. The right supraclavicular fossa ultrasound view for correct catheter tip positioning in right subclavian vein catheterisation: a prospective observational study. Anaesthesia. 2022 Jan;77(1):66-72. doi: 10.1111/anae.15534. Epub 2021 Jul 14.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CVC positioning
Identifier Type: -
Identifier Source: org_study_id