SyncAV Study: Investigation of the Efficacy of the SyncAV Fusion Pacing Algorithm on Exercise
NCT ID: NCT03768804
Last Updated: 2020-11-17
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
22 participants
INTERVENTIONAL
2019-05-31
2021-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
A new approach to optimizing CRT programming has been proposed known as 'fusion-pacing'. This allows the electrical wave from the heart's own conduction system to merge or fuse with the impulse from the pacemaker in the left ventricle. The timing of the pacemaker's impulse is continuously adjusted to measurements the device makes of the hearts natural conduction. What is not clear is how effective 'fusion-pacing' is during exercise when the hearts natural conduction changes rapidly and unpredictably. We plan to investigate this by monitoring the electrocardiogram ("ECG") whilst accurately measuring exercise performance and ability during a cardiopulmonary exercise test ("CPET") on an exercise bike. We will also ask participants to rate their perceived exercise intensity to see whether fusion pacing improves ECG resynchronization, exercise performance, and patients' symptoms compared to standard programming.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Multiple randomised controlled trials have demonstrated that cardiac resynchronization therapy pacemaker devices ("CRT") are an effective therapy for patients with poor pumping function and altered electrical conduction of the heart (left bundle branch block, "LBBB"), improving both morbidity and mortality. However, only 60-70% of patients notice a symptomatic improvement with CRT and even in patients who do respond, response can often be improved further by optimising how the device is programmed.
CRT devices improve coordination of heart pumping by pacing both ventricles of the heart. A key function of this is to coordinate the timing of contraction of the the atria and the ventricles (atrio-ventricular, or "AV", optimisation). This allows maximal filling of the left ventricle with blood. More recently, it has become important not only in standard bi-ventricular ("BiV") pacing, but to allow left ventricular pacing to be timed with intrinsic conduction to the right ventricle to provide CRT (so called 'fusion' pacing).
Multiple methods have been described to assess AV optimisation, including echocardiographic measurements. However, echo based methods are labour intensive, and their value is uncertain. Device algorithms utilising analysis of the intra-cardiac electrogram ("IEGM") have become an attractive alternative due to their rapid and automated nature, although evidence suggests that they may not have clinical benefit over using fixed AV delays. In addition, intrinsic AV conduction is known to alter with exercise, normally becoming shorter. Optimisation of AV delays in CRT on exercise has been shown to improve cardiac output. Device algorithms can therefore allow dynamic adjustment of AV delays as they change with exercise and heart rate (rate-adaptive AV delay or "RAAVD"). Indeed, use of individually tailored RAAVD in CRT patients has demonstrated an increase in exercise capacity.
Patients with heart failure and LBBB often have normal intrinsic right ventricular activation through the right bundle. Utilization of timed left ventricular ("LV") pacing to merge (or fuse) with this intrinsic conduction may confer benefits over standard BiV pacing, but requires relatively normal intrinsic AV conduction as well as correct timing of LV pacing to right ventricular ("RV") activation. Algorithms now exist which allow dynamic reassessment of intrinsic conduction and so adjustment of the optimal AV delay. They can therefore compensate for changes in the intrinsic AV delay on exercising, and so maintain adequate fusion pacing and CRT optimisation. One such software algorithm is SyncAV, developed by Abbott (Abbott Vascular, 3200 Lakeside Drive, Santa Clara, California 95054-2807). SyncAVTM assesses intrinsic AV conduction every 256 beats. It then sets a shorter programmed AV delay by subtracting a set period (known as the "delta" - adjustable but nominally set to 50ms) from the intrinsic time.
There is some evidence that fusion pacing gives benefit in terms of both acute pumping function of the heart and long term response to CRT. However, what remains unclear is whether the effect of dynamic AV optimisation and fusion pacing is maintained on exercise. Firstly, the re-analysis and adjustment intervals may be insufficient to allow effective fusion throughout exercise. It is therefore possible that with rapidly changing heart rates this coordinated timing is lost, leading to inefficient conduction of electricity through the heart. This could result in large periods of time on exercising without effective CRT and so poor exercise tolerance. Secondly, there is evidence that in patients with heart failure AV intervals do not alter with change in heart rate in a similar way to healthy controls. One study found that the degree of change is greater on exercise, whilst one demonstrated that in a CRT population only a third of patients had shorter optimal AV delay intervals on exercise, with a third being unchanged and a third longer. The use of a fixed "delta" in SyncAVTM may therefore result in incorrect adjustment of AV intervals as intrinsic conduction changes, with the effectiveness of SyncAV therefore depending on how the intrinsic interval changes.
We will use a prospective single-centre randomized single-blind crossover study to investigate the effectiveness of SyncAV on exercise, by randomising participants to either use of SyncAV or fixed AV delays, and then carrying out cardiopulmonary exercise testing ("CPET").
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
TRIPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
SyncAV algorithm on
Device randomised to have SyncAV on, with delta programmed to the value which gives the narrowest QRS duration at rest and pseudo left ventricular ("LV") only pacing
SyncAV algorithm on
Cardiac Resynchronisation Device will be set to have the SyncAV algorithm on for the duration of the cardiopulmonary exercise test ("CPET"), before being reset to pre-existing settings
SyncAV algorithm off
Device randomised to have SyncAV off, with a fixed sensed atrioventricular ("AV") delay of 120ms or shorter if necessary to prevent fusion, and biventricular ("BiV") pacing
SyncAV algorithm off
ardiac Resynchronisation Device will be set to have the SyncAV algorithm off and a fixed AV delay, for the duration of the CPET, before being reset to pre-existing settings
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
SyncAV algorithm on
Cardiac Resynchronisation Device will be set to have the SyncAV algorithm on for the duration of the cardiopulmonary exercise test ("CPET"), before being reset to pre-existing settings
SyncAV algorithm off
ardiac Resynchronisation Device will be set to have the SyncAV algorithm off and a fixed AV delay, for the duration of the CPET, before being reset to pre-existing settings
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patients with existing cardiac resynchronization therapy ("CRT") devices able to utilise the SyncAV algorithm, implanted ≥6 months and under follow up at Oxford University Hospitals National Health Service ("NHS") Foundation Trust.
* Evidence of response to CRT, defined as functional improvement or left ventricular ("LV") remodelling on imaging.
* Sinus rhythm and PR interval \<250ms.
* Able to exercise to perform cardiopulmonary exercise testing ("CPET").
Exclusion Criteria
* Atrial fibrillation or atrial tachycardia.
* Underlying 2nd or 3rd degree heart block.
* PR interval ≥250ms.
* Chronotropic incompetence, defined as use of rate-response algorithm or ≥80% atrial pacing.
* Any concurrent condition contraindicating use of CPET.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Oxford
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Neil Herring, BMBCh MRCP
Role: PRINCIPAL_INVESTIGATOR
University of Oxford
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Department of Physiology, Anatomy and Genetics, University of Oxford
Oxford, Oxfordshire, United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
13808
Identifier Type: -
Identifier Source: org_study_id