Transcranial Magnetic Stimulation for Attention Deficit/Hyperactivity Disorder (ADHD)
NCT ID: NCT03663179
Last Updated: 2022-08-05
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
32 participants
INTERVENTIONAL
2017-01-31
2020-01-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Transcranial Magnetic Stimulation in Treatment of Attention Deficit/Hyperactivity Disorders
NCT01618110
Evaluation of the Effect of rTMS on Attention in Adults Diagnosed With Attention-Deficit Hyperactivity Disorder (ADHD)
NCT00825708
Finding Alternatives to Standard Treatment for Attention-Deficit Hyperactivity Disorder
NCT04532190
Four-week Open-trial Extension TNS for ADHD
NCT03870737
rTMS in Children and Adolescents With ADHD:
NCT06389864
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
TRIPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Active TMS
Participants will receive 20 sessions of active TMS targeting the left DLPFC.
Transcranial Magnetic Stimulation (TMS)
A MagPro R30 (Magventure, Inc., Copenhagen, Denmark) device with a Cool-B65 A/P figure 8 coil will be used to deliver TMS. This coil has an active side and a sham side, and can be used to perform double-blinded studies. TMS will be administered at 10 Hertz (Hz) with an intensity of 120% of patient resting motor threshold. Stimulation will be delivered to the left dorsolateral prefrontal cortex using 20 sec cycles (i.e., 5 sec train with 15 sec inter train interval). Subjects will receive 80 trains per session for a total of 4000 pulses per session (\~26 min sessions). Twenty sessions will be completed on sequential weekdays (5 days per week for 4 weeks).
Sham TMS
Participants will receive 20 sessions of sham TMS over the left DLPFC.
Sham Transcranial Magnetic Stimulation (Sham TMS)
A MagPro R30 (Magventure, Inc., Copenhagen, Denmark) device with a Cool-B65 A/P figure 8 coil will be used to deliver TMS. This coil has an active side and a sham side, and can be used to perform double-blinded studies. For sham stimulation, the sham side of the coil is positioned toward the participant's scalp. The sham coil is designed to mimic the appearance and sound of active TMS stimulation, but is equipped with a magnetic shield that reduces the strength of the field by approximately 80%. This reduction in field strength ensures that no neural stimulation occurs. Twenty sessions will be completed on sequential weekdays (5 days per week for 4 weeks).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Transcranial Magnetic Stimulation (TMS)
A MagPro R30 (Magventure, Inc., Copenhagen, Denmark) device with a Cool-B65 A/P figure 8 coil will be used to deliver TMS. This coil has an active side and a sham side, and can be used to perform double-blinded studies. TMS will be administered at 10 Hertz (Hz) with an intensity of 120% of patient resting motor threshold. Stimulation will be delivered to the left dorsolateral prefrontal cortex using 20 sec cycles (i.e., 5 sec train with 15 sec inter train interval). Subjects will receive 80 trains per session for a total of 4000 pulses per session (\~26 min sessions). Twenty sessions will be completed on sequential weekdays (5 days per week for 4 weeks).
Sham Transcranial Magnetic Stimulation (Sham TMS)
A MagPro R30 (Magventure, Inc., Copenhagen, Denmark) device with a Cool-B65 A/P figure 8 coil will be used to deliver TMS. This coil has an active side and a sham side, and can be used to perform double-blinded studies. For sham stimulation, the sham side of the coil is positioned toward the participant's scalp. The sham coil is designed to mimic the appearance and sound of active TMS stimulation, but is equipped with a magnetic shield that reduces the strength of the field by approximately 80%. This reduction in field strength ensures that no neural stimulation occurs. Twenty sessions will be completed on sequential weekdays (5 days per week for 4 weeks).
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
1. Healthy males and females who are between 18 and 65 years of age with an ADHD diagnosis (meet diagnostic criteria for ADHD on the SCID-5 module for adult ADHD).
2. Planning to live in the area for at least the next 6 weeks;
3. Capable of giving written informed consent, which includes compliance with the requirements and restrictions listed in the combined consent and HIPAA form;
4. Able to communicate fluently in English (speaking, writing, and reading).
Exclusion Criteria
Alcohol/Drugs:
1. History or current diagnosis or treatment for alcohol or drug abuse (as reported during phone screen);
2. Positive breath alcohol concentration test (BrAC greater than or equal to 0.01) at intake;
3. A positive urine drug screen for cocaine, phencyclidine (PCP), amphetamines, methamphetamines, benzodiazepines, methadone, and/or barbiturates at Intake, Baseline, or Sessions 5, 10, 15 or 20.
Medication:
Current use or recent discontinuation (within the past 6 months at the time of Intake) of:
1. Gamma-Aminobutyric Acid (GABA)-ergic medications
2. Glutamatergic medications
3. Any medication for the treatment of ADHD
4. Benzodiazepines
5. Any medication that is known to lower the seizure threshold (e.g.,clozapine, bupropion, tramadol, carbapenems, stimulants)
6. Any medication that could compromise participant safety as determined by the Principal Investigator and/or Study Physician
Current use or recent discontinuation (within the last 14 days at the time of Intake) of:
7. Anti-psychotic medications
8. Nicotine replacement therapy (NRT)
Daily use of:
9. Opiate-containing medications for chronic pain
Medical/Neuropsychiatric:
1. Women who are pregnant, planning a pregnancy, and/or breast feeding.
2. History of seizures, epilepsy, or history of epilepsy in first-degree relative
3. History of stroke or transient ischemic attack (warning stroke)
4. History of traumatic brain injury or self-report of brain or spinal tumor
5. History of head injury with unconsciousness lasting more than 5 minutes
6. Previous brain surgery
7. Any additional neurological condition that would likely reduce the safety of study participation, including central nervous system (CNS) vasculitis, intracranial tumor, intracranial aneurysm, multiple sclerosis or arteriovenous malformations
8. History of tinnitus
9. History of diabetes mellitus
10. History of atherosclerotic vascular disease
11. A medically unstable cardiopulmonary or metabolic disorder
12. Increased risk for myocardial infarction or other major cardiopulmonary complications.
13. Any uncorrected visual impairment or abnormality
14. Self-reported history, current diagnosis of psychosis or symptoms consistent with a mood disorder based upon the Structured Clinical Interview for DSM-5 (SCID); including schizophrenia, mania, bipolar disorder, an eating disorder, obsessive compulsive disorder, an anxiety disorder, major depression (subjects with a history of major depression but in remission for past 6 months are eligible).
TMS-related:
1. Subjects with ferromagnetic material in or in close proximity to the head (with the exception of oral dental devices)
2. Implanted devices (including vagus nerve stimulator (VNS), deep brain stimulator (DBS), pacemakers, spinal cord stimulators, medication pumps, ventriculo peritoneal shunts, defibrillators, intracardiac lines)
3. Self-report of any skull fracture or opening
4. A disturbance in normal sleep patterns/sleep deprivation
General Exclusion:
1. Any medical condition, illness, disorder, or concomitant medication that could compromise participant safety or treatment, or affect clinical or cognitive outcomes, as determined by the Principal Investigator
2. Inability to complete study tasks and provide quality data, as determined by the Principal Investigator
3. Low or borderline intellectual functioning - determined by a score of less than 90 on the Shipley Institute of Living Scale (SILS) (administered at Intake Visit). The SILS correlates with the Wechsler Adult Intelligence Scale-Revised (WAIS-R) Estimated Intelligence Quotient (IQ) Test
4. Inability to provide informed consent
18 Years
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Pennsylvania
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
James Loughead, PhD
Role: PRINCIPAL_INVESTIGATOR
University of Pennsylvania
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Pennsylvania
Philadelphia, Pennsylvania, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
826586
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.