Phacoemulsification Versus Phacoemulsification With Micro-bypass Stent

NCT ID: NCT03647033

Last Updated: 2018-10-31

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

32 participants

Study Classification

INTERVENTIONAL

Study Start Date

2015-10-14

Study Completion Date

2017-08-12

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Assessing the safety and efficacy of a micro-bypass stent in combination with cataract surgery in subjects with primary angle closure. Subjects are randomized into two arms: phacoemulsification cataract surgery alone versus phacoemulsification cataract surgery combined with the micro-bypass stent implantation. Post surgery intraocular eye pressure will be recorded to assess the efficacy of both arms.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Aim: To assess the safety and efficacy of the iStent trabecular micro-bypass stent (Glaukos Corporation, Laguna Hills, CA) in combination with cataract surgery in subjects with primary angle closure and mild to moderate primary angle closure glaucoma

Method: Prospective, randomised controlled trial, blinded to patient and intra-ocular pressure measuring staff. 32 patients, 1:1 ratio, in 2 arms of phacoemulsification alone compared to phacoemulsification with iStent.

Hypothesis: Phacoemulsification with micro-bypass stent has a better intraocular pressure (IOP) lowering effect compared to phacoemulsification alone in primary angle closure and primary angle closure glaucoma at 1 year after surgery.

Importance: Primary angle closure and primary angle closure glaucoma are conventionally treated with eye drops that lower the intraocular pressure (IOP). Phacoemulsification/lens extraction can often help lower the eye pressure by widening the drainage angle and via ultrasound mechanisms, however, in some cases the IOP is not lowered, or even can cause the IOP to be higher. The iStent implant can be used together with phacoemulsification to lower the IOP and in Primary open angle glaucoma, it gives an additional 20% IOP reduction. It is unclear what effect the iStent has in primary angle closure or primary angle closure glaucoma as it has never been studied. It is important because primary angle closure glaucoma is much more common in the Singaporean Chinese population and the iStent can potentially be used to control the IOP instead of conventional eye drops and glaucoma surgery which have their own potential adverse effects.

Potential Benefits: iStent with phacoemulsification may control the IOP better than phacoemulsification alone, reduce the need for IOP lowering medication after surgery, and prevent the need for glaucoma surgery in the future.

Potential Risks: The iStent has risks of IOP spikes, bleeding in the anterior chamber and iStent dislocation.Phacoemulsification has the risks of: infection, bleeding, reduced vision, inflammation, posterior capsular rupture, vitreous loss, retinal detachment, endophthalmitis, suprachoroidal haemorrhage and Intraocular Lens dislocation.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Primary Angle-Closure Glaucoma Primary Angle Closure Without Glaucoma Damage

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

istent primary angle closure

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Single centre, randomised prospective trial, the patient and the intraocular pressure (IOP)checking staff will be blinded. Randomised by random envelope shuffle technique.

1:1 ratio allocation 2 arms: phacoemulsification alone and phacoemulsification and iStent. 16 patients in each arm, 32 patients in total. The post-operative management is the same for both arms After operation the patient will be followed up at day 1, week 1, week 2, months 1, 3, 6 and 12.

At each visit the patient will have the following tests: Tonometry (IOP check) - Not to be taken by the operating surgeon, to be taken by 2 people, one IOP checker and one reader.
Primary Study Purpose

TREATMENT

Blinding Strategy

DOUBLE

Participants Outcome Assessors
Shuffled envelope system. Patient will be blinded to the procedure. The intraocular pressure (IOP) measure and reader will be blinded to the procedure.

There will be no planned breaking of randomization. Unplanned breaking will happen if any envelopes are damaged or lost. Unmasking will take place after 1 year post operation by the study team to inform the patient of the procedure.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

phacoemulsification alone

routine phacoemulsification cataract surgery with intraocular lens implantation

Group Type NO_INTERVENTION

No interventions assigned to this group

phacoemulsification and iStent

phacoemulsification cataract surgery with intraocular lens implantation combined with iStent implantation

Group Type EXPERIMENTAL

iStent implantation

Intervention Type DEVICE

The iStent is a FDA and Health Sciences Authority (HSA) approved micro-bypass stent device that bypasses the trabecular meshwork (filtration membrane of the aqueous fluid exit pathway) and reroutes aqueous from the anterior chamber directly into canal of Schlemm and out of the eye. It lowers the intraocular pressure (IOP) by increasing the outflow of fluid from the eye from the micro-bypass. In angle closure, the lens has to be removed to create enough space for the iStent to be inserted.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

iStent implantation

The iStent is a FDA and Health Sciences Authority (HSA) approved micro-bypass stent device that bypasses the trabecular meshwork (filtration membrane of the aqueous fluid exit pathway) and reroutes aqueous from the anterior chamber directly into canal of Schlemm and out of the eye. It lowers the intraocular pressure (IOP) by increasing the outflow of fluid from the eye from the micro-bypass. In angle closure, the lens has to be removed to create enough space for the iStent to be inserted.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* able to provide informed consent
* Previous diagnosis of Primary Angle Closure or Primary Angle Closure Glaucoma
* Intraocular Pressure above 21mmHg at 3 separate visits
* On 1 or more hypotensive medications
* Pre-operative visual acuity of no better than 6/12

Exclusion Criteria

* Other glaucoma diagnosis: Primary Open Angle Glaucoma, secondary glaucoma
* Peripheral Anterior Synechiae in the nasal and inferior quadrant
* Cloudy cornea affecting view for iStent implantation
* Previous glaucoma surgery
* History of Ocular trauma
* Ocular surface disease
* Pre-proliferative or proliferative diabetic retinopathy
* Age related macular degeneration with macular scar or macular atrophy
Minimum Eligible Age

21 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Khoo Teck Puat Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Philemon Huang, MMed, FAMS

Role: PRINCIPAL_INVESTIGATOR

National Healthcare Group, Singapore

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Khoo Teck Puat Hospital

Singapore, , Singapore

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Singapore

References

Explore related publications, articles, or registry entries linked to this study.

Craven ER, Katz LJ, Wells JM, Giamporcaro JE; iStent Study Group. Cataract surgery with trabecular micro-bypass stent implantation in patients with mild-to-moderate open-angle glaucoma and cataract: two-year follow-up. J Cataract Refract Surg. 2012 Aug;38(8):1339-45. doi: 10.1016/j.jcrs.2012.03.025.

Reference Type BACKGROUND
PMID: 22814041 (View on PubMed)

Fea AM. Phacoemulsification versus phacoemulsification with micro-bypass stent implantation in primary open-angle glaucoma: randomized double-masked clinical trial. J Cataract Refract Surg. 2010 Mar;36(3):407-12. doi: 10.1016/j.jcrs.2009.10.031.

Reference Type BACKGROUND
PMID: 20202537 (View on PubMed)

Malvankar-Mehta MS, Iordanous Y, Chen YN, Wang WW, Patel SS, Costella J, Hutnik CM. iStent with Phacoemulsification versus Phacoemulsification Alone for Patients with Glaucoma and Cataract: A Meta-Analysis. PLoS One. 2015 Jul 6;10(7):e0131770. doi: 10.1371/journal.pone.0131770. eCollection 2015.

Reference Type BACKGROUND
PMID: 26147908 (View on PubMed)

Samuelson TW, Katz LJ, Wells JM, Duh YJ, Giamporcaro JE; US iStent Study Group. Randomized evaluation of the trabecular micro-bypass stent with phacoemulsification in patients with glaucoma and cataract. Ophthalmology. 2011 Mar;118(3):459-67. doi: 10.1016/j.ophtha.2010.07.007. Epub 2010 Sep 15.

Reference Type BACKGROUND
PMID: 20828829 (View on PubMed)

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol

View Document

Document Type: Informed Consent Form

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2015/00644

Identifier Type: -

Identifier Source: org_study_id