Trial Outcomes & Findings for Evaluation of the Ability of Newly Developed Adhesives to Absorb Moisture (NCT NCT03619226)

NCT ID: NCT03619226

Last Updated: 2025-07-11

Results Overview

The outcome measure is described as number of events where the sensor system reacted to a false positive leak. Moisture in adhesive is measured using a sensor system. Moisture influences the resistance of the sensor system. Intense moisture/sweat does not result in false positive leak signals. The signal response to moisture/sweat is different to the response to leaks.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

6 participants

Primary outcome timeframe

3 days

Results posted on

2025-07-11

Participant Flow

Participant milestones

Participant milestones
Measure
Test Patch (Adhesive Patch With Sensor System) + Hard Physical Activities + Normal Daily Activities
Two adhesive patches are applied to the abdominal area on two consecutive days. The first patch is worn with normal daily activities and the second patch is stress tested during half an hour spinning activities in humid environment plus normal day activities.
Overall Study
STARTED
6
Overall Study
COMPLETED
6
Overall Study
NOT COMPLETED
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Race and Ethnicity were not collected from any participant.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Test Patch
n=6 Participants
two adhesive patches are applied to the abdominal area test patch: the test patch consists of an adhesive patch
Age, Continuous
37 years
STANDARD_DEVIATION 9 • n=6 Participants
Sex: Female, Male
Female
6 Participants
n=6 Participants
Sex: Female, Male
Male
0 Participants
n=6 Participants

PRIMARY outcome

Timeframe: 3 days

Population: Healthy volunteers

The outcome measure is described as number of events where the sensor system reacted to a false positive leak. Moisture in adhesive is measured using a sensor system. Moisture influences the resistance of the sensor system. Intense moisture/sweat does not result in false positive leak signals. The signal response to moisture/sweat is different to the response to leaks.

Outcome measures

Outcome measures
Measure
Test Patch (Adhesive Patch With Sensor System) + Normal Daily Activities
n=6 Participants
two adhesive patches are applied to the abdominal area on two consecutive days. The first patch is worn with normal daily activities and the second patch is stress tested during half an hour spinning activities in humid environment plus normal day activities.
Test Patch (Adhesive Patch With Sensor System) + Hard Physical Activities + Normal Daily Activities
n=6 Participants
two adhesive patches are applied to the abdominal area on two consecutive days. The first patch is worn with normal daily activities and the second patch is stress tested during half an hour spinning activities in humid environment plus normal day activities.
Resistance (Moisture in the Adhesive)
0 Number of false positive leaks
0 Number of false positive leaks

Adverse Events

Test Patch (Adhesive Patch With Sensor System) + Hard Physical Activities + Normal Daily Activities

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Julie Schnipper, Medical Writer

Coloplast A/S

Phone: 49111257

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place