Trial Outcomes & Findings for DEF-314 Better Accuracy in Ejection Fraction (EF) Assessment With DEFINITY (NCT NCT03571672)
NCT ID: NCT03571672
Last Updated: 2020-12-17
Results Overview
Demonstrate improvement in accuracy in left ventricular ejection fraction (LVEF) assessment using Definity contrast-enhanced over unenhanced echocardiography by comparing LVEF Percentage Differences from CMR measured by 3 independent blinded image readers.
COMPLETED
PHASE3
153 participants
Up to 30 days between day of echocardiograms and CMR imaging
2020-12-17
Participant Flow
Participant milestones
| Measure |
Definity
Each patient will undergo an unenhanced ultrasound examination and a DEFINITY contrast-enhanced ultrasound
DEFINITY: All subjects will receive a single dose of DEFINITY®
|
|---|---|
|
Overall Study
STARTED
|
153
|
|
Overall Study
COMPLETED
|
148
|
|
Overall Study
NOT COMPLETED
|
5
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
DEF-314 Better Accuracy in Ejection Fraction (EF) Assessment With DEFINITY
Baseline characteristics by cohort
| Measure |
Definity
n=153 Participants
Each patient will undergo an unenhanced ultrasound examination and a DEFINITY contrast-enhanced ultrasound
DEFINITY: All subjects will receive a single dose of DEFINITY®
|
|---|---|
|
Age, Categorical
<=18 years
|
0 Participants
n=5 Participants
|
|
Age, Categorical
Between 18 and 65 years
|
98 Participants
n=5 Participants
|
|
Age, Categorical
>=65 years
|
55 Participants
n=5 Participants
|
|
Sex: Female, Male
Female
|
51 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
102 Participants
n=5 Participants
|
|
Ethnicity (NIH/OMB)
Hispanic or Latino
|
18 Participants
n=5 Participants
|
|
Ethnicity (NIH/OMB)
Not Hispanic or Latino
|
135 Participants
n=5 Participants
|
|
Ethnicity (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
2 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Asian
|
3 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
4 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Black or African American
|
37 Participants
n=5 Participants
|
|
Race (NIH/OMB)
White
|
104 Participants
n=5 Participants
|
|
Race (NIH/OMB)
More than one race
|
3 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
|
LVEF Group
LVEF <30%
|
35 Participants
n=5 Participants
|
|
LVEF Group
LVEF 30-40%
|
40 Participants
n=5 Participants
|
|
LVEF Group
LVEF 41-50%
|
39 Participants
n=5 Participants
|
|
LVEF Group
LVEF >50%
|
39 Participants
n=5 Participants
|
PRIMARY outcome
Timeframe: Up to 30 days between day of echocardiograms and CMR imagingPopulation: Modified ITT Population
Demonstrate improvement in accuracy in left ventricular ejection fraction (LVEF) assessment using Definity contrast-enhanced over unenhanced echocardiography by comparing LVEF Percentage Differences from CMR measured by 3 independent blinded image readers.
Outcome measures
| Measure |
Blinded Reader 1
n=145 Participants
Independent Blinded Reader 1 of 3
|
Blinded Reader 2
n=145 Participants
Independent Blinded Reader 2 of 3
|
Blinded Reader 3
n=145 Participants
Independent Blinded Reader 3 of 3
|
|---|---|---|---|
|
Absolute Value of LVEF Percentage Differences From CMR by Blinded Reader
Echo Enhanced
|
6.10 Percent Ejection Fraction
Standard Deviation 5.319
|
6.38 Percent Ejection Fraction
Standard Deviation 5.227
|
4.93 Percent Ejection Fraction
Standard Deviation 4.288
|
|
Absolute Value of LVEF Percentage Differences From CMR by Blinded Reader
Echo Unenhanced
|
6.18 Percent Ejection Fraction
Standard Deviation 5.300
|
6.61 Percent Ejection Fraction
Standard Deviation 5.256
|
5.36 Percent Ejection Fraction
Standard Deviation 4.498
|
SECONDARY outcome
Timeframe: Up to 30 days between day of echocardiograms and CMR imagingPopulation: Per-protocol population - Sub-optimal Echocardiograms
Demonstrate improvement in accuracy in left ventricular ejection fraction (LVEF) assessment using DEFINITY® contrast-enhanced over unenhanced echocardiography in subjects with suboptimal echocardiograms by comparing LVEF percentage differences from CMR measured by 3 independent readers.
Outcome measures
| Measure |
Blinded Reader 1
n=59 Participants
Independent Blinded Reader 1 of 3
|
Blinded Reader 2
n=59 Participants
Independent Blinded Reader 2 of 3
|
Blinded Reader 3
n=59 Participants
Independent Blinded Reader 3 of 3
|
|---|---|---|---|
|
Secondary Objective 1: Absolute Value of LVEF Percentage Differences From CMR by Blinded Reader for Suboptimal Echocardiograms
Echo Enhanced
|
7.48 Percent Ejection Fraction
Standard Deviation 6.228
|
7.16 Percent Ejection Fraction
Standard Deviation 6.337
|
5.71 Percent Ejection Fraction
Standard Deviation 5.293
|
|
Secondary Objective 1: Absolute Value of LVEF Percentage Differences From CMR by Blinded Reader for Suboptimal Echocardiograms
Echo Unenhanced
|
7.16 Percent Ejection Fraction
Standard Deviation 6.184
|
7.12 Percent Ejection Fraction
Standard Deviation 5.381
|
5.89 Percent Ejection Fraction
Standard Deviation 4.523
|
SECONDARY outcome
Timeframe: Up to 30 days between day of echocardiograms and CMR imagingPopulation: Per-Protocol Population
Demonstrate a reduction in inter-reader variability for the assessment of left ventricular ejection fraction using DEFINITY® contrast-enhanced versus unenhanced echocardiography by comparing LVEF Percentage Differences from CMR between 3 independent blinded readers
Outcome measures
| Measure |
Blinded Reader 1
n=145 Participants
Independent Blinded Reader 1 of 3
|
Blinded Reader 2
n=145 Participants
Independent Blinded Reader 2 of 3
|
Blinded Reader 3
n=145 Participants
Independent Blinded Reader 3 of 3
|
|---|---|---|---|
|
Secondary Objective 2: Absolute Value LVEF Percentage Differences From CMR Between Blinded Readers
Echo Enhanced
|
6.10 Percent Ejection Fraction
Standard Deviation 5.319
|
6.38 Percent Ejection Fraction
Standard Deviation 5.227
|
4.93 Percent Ejection Fraction
Standard Deviation 4.288
|
|
Secondary Objective 2: Absolute Value LVEF Percentage Differences From CMR Between Blinded Readers
Echo Unenhanced
|
6.18 Percent Ejection Fraction
Standard Deviation 0.164
|
6.61 Percent Ejection Fraction
Standard Deviation 5.256
|
5.36 Percent Ejection Fraction
Standard Deviation 4.498
|
SECONDARY outcome
Timeframe: Up to 30 days between day of echocardiograms and CMR imagingPopulation: Modified ITT Population
Demonstrate a reduction in inter-reader variability for the assessment of end-diastolic and systolic volumes using DEFINITY® contrast-enhanced versus unenhanced echocardiography by comparing end-diastolic and systolic volume differences from CMR between 3 independent blinded readers.
Outcome measures
| Measure |
Blinded Reader 1
n=145 Participants
Independent Blinded Reader 1 of 3
|
Blinded Reader 2
n=145 Participants
Independent Blinded Reader 2 of 3
|
Blinded Reader 3
n=145 Participants
Independent Blinded Reader 3 of 3
|
|---|---|---|---|
|
Secondary Objective 3: Absolute Value End-Diastolic and Systolic Volume Differences From CMR Between Blinded Readers
Echo Enhanced End Diastolic
|
52.31 mL
Standard Deviation 35.726
|
46.57 mL
Standard Deviation 33.785
|
39.37 mL
Standard Deviation 26.206
|
|
Secondary Objective 3: Absolute Value End-Diastolic and Systolic Volume Differences From CMR Between Blinded Readers
Echo Unenhanced End Diastolic
|
58.02 mL
Standard Deviation 38.483
|
56.65 mL
Standard Deviation 37.766
|
48.07 mL
Standard Deviation 31.620
|
|
Secondary Objective 3: Absolute Value End-Diastolic and Systolic Volume Differences From CMR Between Blinded Readers
Echo Enhanced End Systolic
|
33.56 mL
Standard Deviation 28.641
|
29.93 mL
Standard Deviation 25.845
|
26.01 mL
Standard Deviation 20.740
|
|
Secondary Objective 3: Absolute Value End-Diastolic and Systolic Volume Differences From CMR Between Blinded Readers
Echo Unenhanced End Systolic
|
37.53 mL
Standard Deviation 30.016
|
33.51 mL
Standard Deviation 28.079
|
30.72 mL
Standard Deviation 23.534
|
SECONDARY outcome
Timeframe: Up to 30 days between day of echocardiograms and CMR imagingPopulation: Per Protocol Population - Sub-Optimal Echocardiograms
Demonstrate a reduction in inter-reader variability for the assessment of left ventricular ejection fraction using DEFINITY® contrast-enhanced versus unenhanced echocardiography by comparing LVEF Percentage Differences from CMR between 3 independent blinded readers in subjects with suboptimal echocardiograms.
Outcome measures
| Measure |
Blinded Reader 1
n=59 Participants
Independent Blinded Reader 1 of 3
|
Blinded Reader 2
n=59 Participants
Independent Blinded Reader 2 of 3
|
Blinded Reader 3
n=59 Participants
Independent Blinded Reader 3 of 3
|
|---|---|---|---|
|
Secondary Objective 4: Absolute Value of LVEF Percentage Differences From CMR Between Blinded Readers for Suboptimal Echocardiograms
Echo Enhanced
|
7.48 Percent Ejection Fraction
Standard Deviation 6.228
|
7.16 Percent Ejection Fraction
Standard Deviation 6.337
|
5.71 Percent Ejection Fraction
Standard Deviation 5.293
|
|
Secondary Objective 4: Absolute Value of LVEF Percentage Differences From CMR Between Blinded Readers for Suboptimal Echocardiograms
Echo Unenhanced
|
7.16 Percent Ejection Fraction
Standard Deviation 6.184
|
7.12 Percent Ejection Fraction
Standard Deviation 5.381
|
5.89 Percent Ejection Fraction
Standard Deviation 4.523
|
SECONDARY outcome
Timeframe: Up to 30 days between day of echocardiograms and CMR imagingPopulation: Modified ITT population - Sub Optimal Echocardiograms
Demonstrate a reduction in inter-reader variability for the assessment of end-diastolic/systolic volumes using DEFINITY® contrast-enhanced versus unenhanced echocardiography by comparing end-diastolic and systolic volume differences from CMR between 3 independent blinded readers in subjects with suboptimal echocardiograms.
Outcome measures
| Measure |
Blinded Reader 1
n=59 Participants
Independent Blinded Reader 1 of 3
|
Blinded Reader 2
n=59 Participants
Independent Blinded Reader 2 of 3
|
Blinded Reader 3
n=59 Participants
Independent Blinded Reader 3 of 3
|
|---|---|---|---|
|
Secondary Objective 5: Absolute Value End-Diastolic and Systolic Volume Differences From CMR Between Blinded Readers for Suboptimal Echocardiograms
Echo Enhanced End Diastolic
|
62.34 mL
Standard Deviation 40.035
|
54.68 mL
Standard Deviation 37.571
|
45.44 mL
Standard Deviation 29.702
|
|
Secondary Objective 5: Absolute Value End-Diastolic and Systolic Volume Differences From CMR Between Blinded Readers for Suboptimal Echocardiograms
Echo Unenhanced End Diastolic
|
65.45 mL
Standard Deviation 43.227
|
63.25 mL
Standard Deviation 41.700
|
53.77 mL
Standard Deviation 34.210
|
|
Secondary Objective 5: Absolute Value End-Diastolic and Systolic Volume Differences From CMR Between Blinded Readers for Suboptimal Echocardiograms
Echo Enhanced End Systolic
|
39.52 mL
Standard Deviation 29.712
|
34.00 mL
Standard Deviation 26.955
|
30.12 mL
Standard Deviation 22.174
|
|
Secondary Objective 5: Absolute Value End-Diastolic and Systolic Volume Differences From CMR Between Blinded Readers for Suboptimal Echocardiograms
Echo Unenhanced End Systolic
|
39.45 mL
Standard Deviation 33.303
|
33.97 mL
Standard Deviation 29.233
|
32.78 mL
Standard Deviation 24.522
|
Adverse Events
Definity
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place