Optic Nerve Head Structural Response to IOP Elevation in Patients With Keratoconus
NCT ID: NCT03560609
Last Updated: 2025-01-29
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
TERMINATED
NA
3 participants
INTERVENTIONAL
2018-11-15
2024-01-19
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
It is hypothesized that subjects with keratoconus have an abnormal biomechanical response of the lamina cribrosa in response to IOP modulation.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Safety & Efficacy of the Laser Scleral Microporation Procedure
NCT05068479
CHOICE OF SUBJECTIVE OCULAR REFRACTION TECHNIQUE AND CORNEAL TOPOGRAPHY OF KERATOCONUS
NCT04174209
Corneal Biomechanics Study
NCT03658239
OCT in Diagnosis of Irregular Corneas
NCT03504800
Study to Evaluate the Safety and Efficacy of Epi-on Corneal Cross-linking in Eyes With Progressive Keratoconus
NCT03442751
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Subjects With Keratoconus
Ophthalmodynamometer
The ODM (Baillart ophthlmodynamometer) is a disc attached to a piston that induces a controlled force on a fixed area. The device will be used to apply a pressure within the range of 10 mmHg - 50 mmHg 4 times to each eye. Each increase of pressure will last approximately 30 seconds. The device is FDA approved and will be used as routinely used in clinical practice
Goldmann applanation tonometer
The Goldmann applanation tonometer (Haag-Streit, Basel, Switzerland) measures the IOP after the eye is numbed with a drop of anesthetic (proparacaine), which is approved by the FDA. Proparacaine is part of routine patient care using a tonometer regardless of participation in this study. The instrument's tip lightly touches the surface of the cornea and the IOP is measured. The device is FDA approved is routinely used in clinical practice.
Pentacam
This device maps the cornea and provides pachymetry, topography and corneal aberration maps. The device is FDA approved and routinely used in clinical practice.
ORA
ORA is an air puff tonometer that applies controlled force to flattens the cornea and provides the corneal hysteresis and corneal resistance factor. The device is FDA approved and routinely used in clinical practice.
Optical Coherence Tomography (OCT)
OCT is a non-contact,real-time, high resolution, and reproducible imaging modality that provides in-vivo optical cross-sectional scanning of the retina, the ONH and of the anterior segment structures including the cornea. Clinical staff will perform subject testing, not research coordinators. Information about these non-FDA approved OCTs and the multi-modal adaptive optics system can be found in appendices A, B, C, and D. With all devices, the participant sits in a slit lamp like frame. A low power laser light is projected toward the back of their eyes while the subject fixates on a target. None of the systems produce harmful radioactive radiation.
Subjects with Glaucoma
Ophthalmodynamometer
The ODM (Baillart ophthlmodynamometer) is a disc attached to a piston that induces a controlled force on a fixed area. The device will be used to apply a pressure within the range of 10 mmHg - 50 mmHg 4 times to each eye. Each increase of pressure will last approximately 30 seconds. The device is FDA approved and will be used as routinely used in clinical practice
Goldmann applanation tonometer
The Goldmann applanation tonometer (Haag-Streit, Basel, Switzerland) measures the IOP after the eye is numbed with a drop of anesthetic (proparacaine), which is approved by the FDA. Proparacaine is part of routine patient care using a tonometer regardless of participation in this study. The instrument's tip lightly touches the surface of the cornea and the IOP is measured. The device is FDA approved is routinely used in clinical practice.
Pentacam
This device maps the cornea and provides pachymetry, topography and corneal aberration maps. The device is FDA approved and routinely used in clinical practice.
ORA
ORA is an air puff tonometer that applies controlled force to flattens the cornea and provides the corneal hysteresis and corneal resistance factor. The device is FDA approved and routinely used in clinical practice.
Optical Coherence Tomography (OCT)
OCT is a non-contact,real-time, high resolution, and reproducible imaging modality that provides in-vivo optical cross-sectional scanning of the retina, the ONH and of the anterior segment structures including the cornea. Clinical staff will perform subject testing, not research coordinators. Information about these non-FDA approved OCTs and the multi-modal adaptive optics system can be found in appendices A, B, C, and D. With all devices, the participant sits in a slit lamp like frame. A low power laser light is projected toward the back of their eyes while the subject fixates on a target. None of the systems produce harmful radioactive radiation.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Ophthalmodynamometer
The ODM (Baillart ophthlmodynamometer) is a disc attached to a piston that induces a controlled force on a fixed area. The device will be used to apply a pressure within the range of 10 mmHg - 50 mmHg 4 times to each eye. Each increase of pressure will last approximately 30 seconds. The device is FDA approved and will be used as routinely used in clinical practice
Goldmann applanation tonometer
The Goldmann applanation tonometer (Haag-Streit, Basel, Switzerland) measures the IOP after the eye is numbed with a drop of anesthetic (proparacaine), which is approved by the FDA. Proparacaine is part of routine patient care using a tonometer regardless of participation in this study. The instrument's tip lightly touches the surface of the cornea and the IOP is measured. The device is FDA approved is routinely used in clinical practice.
Pentacam
This device maps the cornea and provides pachymetry, topography and corneal aberration maps. The device is FDA approved and routinely used in clinical practice.
ORA
ORA is an air puff tonometer that applies controlled force to flattens the cornea and provides the corneal hysteresis and corneal resistance factor. The device is FDA approved and routinely used in clinical practice.
Optical Coherence Tomography (OCT)
OCT is a non-contact,real-time, high resolution, and reproducible imaging modality that provides in-vivo optical cross-sectional scanning of the retina, the ONH and of the anterior segment structures including the cornea. Clinical staff will perform subject testing, not research coordinators. Information about these non-FDA approved OCTs and the multi-modal adaptive optics system can be found in appendices A, B, C, and D. With all devices, the participant sits in a slit lamp like frame. A low power laser light is projected toward the back of their eyes while the subject fixates on a target. None of the systems produce harmful radioactive radiation.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Keratoconus:
* Clinical diagnosis of keratoconus
* Central thinning of the cornea
* Abnormal posterior ectasia.
Glaucoma:
* Glaucomatous ONH abnormality: rim thinning, notching, undermining (excavation) or diffuse or localized RNFL defects that are characteristic of glaucoma.
* Two consecutive abnormal SITA standard perimetry tests with GHT outside normal limits.
Exclusion Criteria
* Strabismus, nystagmus or a condition that would prevent fixation.
* Diabetes with evidence of retinopathy.
* Previous intraocular surgery or ocular trauma (with the exception of laser procedures and subjects that have undergone uneventful cataract surgery more than 6 months from enrollment date).
* Neurological and non-glaucomatous causes for visual field damage.
* Any intraocular non-glaucomatous ocular disorders.
18 Years
90 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
National Eye Institute (NEI)
NIH
NYU Langone Health
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Chaim Wollstein
Role: PRINCIPAL_INVESTIGATOR
NYU Langone Health
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
New York University School of Medicine
New York, New York, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan