Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
460 participants
INTERVENTIONAL
2018-05-01
2022-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The secondary objectives of this study are to determine whether the Corin Optimised Positioning System (Corin, U.K.) improves functional outcomes, reduces length of hospital stay, and reduces leg length discrepancy compared with standard templating in patients undergoing total hip replacement.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Evaluation of X-ray, Acetabular Guides and CT in THR
NCT03072706
Accuracy of OPS™ Femoral Neck Resection Study
NCT03956381
Wear and Migration in the Corin Mini-Hip/Metafix and ECIMA Polyethylene
NCT02174965
Observational Study to Evaluate Long-Term Outcome in Hip Arthroplasty
NCT02230826
Evaluation of Proprioception in Patients With Total Hip Replacement
NCT05763368
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
One of the largest costs to healthcare providers following THR is dislocation. Although the dislocation rate reported in Joint Registries is between 1 and 3% we know that this significantly underestimates the true problem, as the majority of dislocation events are managed with closed reduction and do not result in revision surgery. It is estimated that dislocation is an order of magnitude more common than reported in Registry data. Literature estimates indicate a true dislocation prevalence of 3 to 15%. The cost of dislocation is significant as the problem is often recurrent, resulting in multiple hospital admissions. The resulting average cost for each patient who suffers a THR dislocation is around £30,000.
The factors that influence dislocation are poorly understood. Conventional surgical wisdom dictates that placing a cup in the Lewinneck 'safe zone' reduces both instability and wear. A recent study of 9784 primary THRs, however, demonstrated that 58% of patients who suffered a dislocation had implants judged to be in a safe position. This has led to suggestions that the idea of one generic 'safe zone' may be misleading; instead, there is a unique optimum position to place a cup in each patient undergoing THR, based on the unique and complex interaction of the spine and pelvis of the individual. Thus, in some patients, whilst the acetabular cup appears well positioned by conventional measures, pelvic tilt and spinal position mean that the cup is placed in a position of instability during some activities.
The Corin Optimised Positioning System (OPS) is a novel platform, designed to enable delivery of the prosthetic acetabular cup into an optimised position for every patient undergoing THR. It comprises two stages: pre-operative planning and intra-operative guidance. Pre-operatively, patients undergo dynamic imaging (computed tomography scanning and X-ray films). The information gained about the relative movements of a patient's spine, pelvis and hips are used to create a personalized physiological profile. This enables calculation of the optimized acetabular cup orientation for each individual. A unique physical guide (which falls under the definition of a custom-made device in the Medical Device Directive) is then created for each patient to fit precisely into the acetabular fossa, for use intra-operatively. Intra-operatively, the Corin OPS uses laser alignment to aid the surgeon in aligning the acetabular cup in the calculated optimised orientation. One laser is affixed to an immovable pelvic screw; the other is attached to the reverse of the acetabular cup. The target orientation of the cup is achieved when the two lasers are aligned.
The aim of this trial is to assess the efficacy of the use of the Corin Optimised Positioning System in reducing post-operative hip dislocation in patients undergoing total hip arthroplasty by comparing it with current standard templating in total hip arthroplasty. All total hip implants/components used in the study will be produced by Corin for uniformity and have the required approvals. There is currently no evidence that this novel approach to templating has an effect on dislocation rate. This project aims to provide evidence that this new technique can improve outcomes for patients and have the potential to reduce the need for complex, expensive revision surgery.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
Comparator arm: total hip replacement, guided by standard templating techniques
TREATMENT
DOUBLE
Outcomes assessors examine patients from 3 months post-operatively. There is no risk they will know which arm the patient is in, as they will not have access to the study database.
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Corin OPS arm
Total hip replacement with use of Corin Optimised Positioning System to guide implant positioning
Corin Optimised Positioning System
Total hip replacement with implant positioning guided by Corin Optimised Positioning System.
The experimental and active comparator arms will use the same implants for total hip replacements. The Corin Trinity shell system will be used for the acetabular system. The Corin MiniHip, TriFit, MetaFix and TaperFit implants will be used for the femoral stem implant. Surgeons will select the implant most appropriate for each patient.
Standard care arm
Total hip replacement with standard templating to guide implant positioning
Standard templating
Total hip replacement with implant positioning guided by standard templating. The experimental and active comparator arms will use the same implants for total hip replacements. The Corin Trinity shell system will be used for the acetabular system. The Corin MiniHip, TriFit, MetaFix and TaperFit implants will be used for the femoral stem implant. Surgeons will select the implant most appropriate for each patient.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Corin Optimised Positioning System
Total hip replacement with implant positioning guided by Corin Optimised Positioning System.
The experimental and active comparator arms will use the same implants for total hip replacements. The Corin Trinity shell system will be used for the acetabular system. The Corin MiniHip, TriFit, MetaFix and TaperFit implants will be used for the femoral stem implant. Surgeons will select the implant most appropriate for each patient.
Standard templating
Total hip replacement with implant positioning guided by standard templating. The experimental and active comparator arms will use the same implants for total hip replacements. The Corin Trinity shell system will be used for the acetabular system. The Corin MiniHip, TriFit, MetaFix and TaperFit implants will be used for the femoral stem implant. Surgeons will select the implant most appropriate for each patient.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Diagnosed with hip OA, post-traumatic OA, inflammatory arthropathy, avascular necrosis, or congenital or developmental hip disease, avascular necrosis of the hip
* Listed for total hip arthroplasty at one of participating centres
* Participant is fit to undergo total hip arthroplasty based on consultant anaesthetist review
* In the Investigator's opinion, is able and willing to comply with all trial requirements
* Willing to allow his or her General Practitioner and consultant, if appropriate, to be notified of participation in the trial
* Female participants of child bearing potential must be willing to ensure that they use effective contraception during the trial
Exclusion Criteria
* Previous surgery to the ipsilateral hip
* Significant co-morbidities that would make follow up difficult or uncomfortable
* Scheduled elective surgery or other procedures requiring general anaesthesia during the trial
* Pregnancy
18 Years
85 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Corin
INDUSTRY
Oxford University Hospitals NHS Trust
OTHER
University of Oxford
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Sion Glyn-Jones, DPhil FRCS
Role: PRINCIPAL_INVESTIGATOR
University of Oxford
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Nuffield Orthopaedic Centre, Oxford University Hospitals Trust
Oxford, , United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IRAS 216084
Identifier Type: -
Identifier Source: org_study_id