Trial Outcomes & Findings for Cathodal tDCS in MCI: A Randomized, Double-Blind, Sham-Controlled Pilot Study (NCT NCT03521089)
NCT ID: NCT03521089
Last Updated: 2020-03-25
Results Overview
Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.
COMPLETED
NA
16 participants
Baseline, 1-month post intervention
2020-03-25
Participant Flow
Participant milestones
| Measure |
Active tDCS
Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
Sham tDCS
Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
|---|---|---|
|
Overall Study
STARTED
|
8
|
8
|
|
Overall Study
COMPLETED
|
8
|
8
|
|
Overall Study
NOT COMPLETED
|
0
|
0
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Cathodal tDCS in MCI: A Randomized, Double-Blind, Sham-Controlled Pilot Study
Baseline characteristics by cohort
| Measure |
Active tDCS
n=8 Participants
Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
Sham tDCS
n=8 Participants
Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
Total
n=16 Participants
Total of all reporting groups
|
|---|---|---|---|
|
Age, Continuous
|
70.0 years
STANDARD_DEVIATION 5.7 • n=5 Participants
|
70.0 years
STANDARD_DEVIATION 9.5 • n=7 Participants
|
70.0 years
STANDARD_DEVIATION 7.5 • n=5 Participants
|
|
Sex: Female, Male
Female
|
2 Participants
n=5 Participants
|
7 Participants
n=7 Participants
|
9 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
6 Participants
n=5 Participants
|
1 Participants
n=7 Participants
|
7 Participants
n=5 Participants
|
|
Ethnicity (NIH/OMB)
Hispanic or Latino
|
1 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
1 Participants
n=5 Participants
|
|
Ethnicity (NIH/OMB)
Not Hispanic or Latino
|
7 Participants
n=5 Participants
|
8 Participants
n=7 Participants
|
15 Participants
n=5 Participants
|
|
Ethnicity (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Asian
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Black or African American
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
White
|
8 Participants
n=5 Participants
|
8 Participants
n=7 Participants
|
16 Participants
n=5 Participants
|
|
Race (NIH/OMB)
More than one race
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Region of Enrollment
United States
|
8 participants
n=5 Participants
|
8 participants
n=7 Participants
|
16 participants
n=5 Participants
|
PRIMARY outcome
Timeframe: Baseline, 1-month post interventionPost-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.
Outcome measures
| Measure |
Active tDCS
n=8 Participants
Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
Sham tDCS
n=8 Participants
Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
|---|---|---|
|
Change in Flanker Inhibitory Control and Attention Test Scores
|
35.1 score on a scale
Standard Error 1.3
|
41.5 score on a scale
Standard Error 1.3
|
PRIMARY outcome
Timeframe: Baseline, 1 month post interventionPost-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.
Outcome measures
| Measure |
Active tDCS
n=8 Participants
Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
Sham tDCS
n=8 Participants
Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
|---|---|---|
|
Change in Picture Vocabulary Test Scores
|
52.0 score on a scale
Standard Error 1.2
|
52.0 score on a scale
Standard Error 1.2
|
PRIMARY outcome
Timeframe: Baseline, 1 month post interventionPost-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.
Outcome measures
| Measure |
Active tDCS
n=8 Participants
Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
Sham tDCS
n=8 Participants
Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
|---|---|---|
|
Change in List Sorting Working Memory Test Scores
|
60.5 score on a scale
Standard Error 1.9
|
51.8 score on a scale
Standard Error 1.9
|
PRIMARY outcome
Timeframe: Baseline, 1 month post interventionPost-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.
Outcome measures
| Measure |
Active tDCS
n=8 Participants
Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
Sham tDCS
n=8 Participants
Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
|---|---|---|
|
Change in Dimensional Change Card Sort Test
|
43.7 score on a scale
Standard Error 2.8
|
48.0 score on a scale
Standard Error 2.8
|
PRIMARY outcome
Timeframe: Baseline, 1 month post interventionPost-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.
Outcome measures
| Measure |
Active tDCS
n=8 Participants
Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
Sham tDCS
n=8 Participants
Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
|---|---|---|
|
Change in Pattern Comparison Processing Speed Test Scores
|
46.6 score on a scale
Standard Error 3.0
|
51.6 score on a scale
Standard Error 3.0
|
PRIMARY outcome
Timeframe: Baseline, 1 month post interventionPost-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.
Outcome measures
| Measure |
Active tDCS
n=8 Participants
Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
Sham tDCS
n=8 Participants
Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
|---|---|---|
|
Change in Picture Sequence Memory Test v2.1 Score
|
45.2 score on a scale
Standard Error 3.8
|
42.8 score on a scale
Standard Error 3.8
|
PRIMARY outcome
Timeframe: Baseline, 1 month post interventionPost-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.
Outcome measures
| Measure |
Active tDCS
n=8 Participants
Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
Sham tDCS
n=8 Participants
Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week.
|
|---|---|---|
|
Change in Oral Reading Recognition Test Score
|
58.5 score on a scale
Standard Error 1.7
|
56.1 score on a scale
Standard Error 1.7
|
Adverse Events
Active tDCS
Sham tDCS
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place