Trial Outcomes & Findings for Short vs Long Dental Implants for the Fixed Rehabilitation of the Fully Edentulous Mandible (NCT NCT03509402)
NCT ID: NCT03509402
Last Updated: 2025-01-13
Results Overview
Marginal bone level (MBL) is measured as the distance in millimiters calculated on periapical radiographs from the implant neck to the most coronal bone-to-implant contact point at both the mesial and the distal side of each implant. The radiographs will be taken with an X-ray apparatus supplied with a long cone and Rinn's film holders.
COMPLETED
NA
30 participants
5 years from baseline (prosthetic loading)
2025-01-13
Participant Flow
Participant milestones
| Measure |
Short Implants
A full-arch screw-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm)
|
Long Implants
A full-arch srew-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal long implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
|
|---|---|---|
|
Overall Study
STARTED
|
15
|
15
|
|
Overall Study
COMPLETED
|
13
|
14
|
|
Overall Study
NOT COMPLETED
|
2
|
1
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Short vs Long Dental Implants for the Fixed Rehabilitation of the Fully Edentulous Mandible
Baseline characteristics by cohort
| Measure |
Short Implants
n=15 Participants
A full-arch screw-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm)
|
Long Implants
n=15 Participants
A full-arch srew-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal long implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
|
Total
n=30 Participants
Total of all reporting groups
|
|---|---|---|---|
|
Age, Continuous
|
63 years
STANDARD_DEVIATION 6.3 • n=5 Participants
|
61 years
STANDARD_DEVIATION 8.6 • n=7 Participants
|
63 years
STANDARD_DEVIATION 7.5 • n=5 Participants
|
|
Sex: Female, Male
Female
|
10 Participants
n=5 Participants
|
3 Participants
n=7 Participants
|
13 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
5 Participants
n=5 Participants
|
12 Participants
n=7 Participants
|
17 Participants
n=5 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Asian
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Black or African American
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
White
|
15 Participants
n=5 Participants
|
15 Participants
n=7 Participants
|
30 Participants
n=5 Participants
|
|
Race (NIH/OMB)
More than one race
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Region of Enrollment
Italy
|
15 participants
n=5 Participants
|
15 participants
n=7 Participants
|
30 participants
n=5 Participants
|
|
Smoking habit
|
3 Participants
n=5 Participants
|
4 Participants
n=7 Participants
|
7 Participants
n=5 Participants
|
PRIMARY outcome
Timeframe: 5 years from baseline (prosthetic loading)Marginal bone level (MBL) is measured as the distance in millimiters calculated on periapical radiographs from the implant neck to the most coronal bone-to-implant contact point at both the mesial and the distal side of each implant. The radiographs will be taken with an X-ray apparatus supplied with a long cone and Rinn's film holders.
Outcome measures
| Measure |
Short Implants
n=13 Participants
A full-arch screw-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm)
|
Long Implants
n=14 Participants
A full-arch srew-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal long implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
|
|---|---|---|
|
Marginal Bone Level (MBL) Change
|
0.30 mm
Standard Deviation 0.31
|
0.40 mm
Standard Deviation 0.23
|
SECONDARY outcome
Timeframe: 5 years from baseline (prosthetic loading)A surviving implant is defined as an implant in place at the time of the follow-up. Any implant loss shall be assessed as an early loss (implant fails before being osseointegrated) or late loss (after being osseointegrated).
Outcome measures
| Measure |
Short Implants
n=13 Participants
A full-arch screw-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm)
|
Long Implants
n=14 Participants
A full-arch srew-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal long implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
|
|---|---|---|
|
Implant Survival Rate
|
65 Implants
|
70 Implants
|
SECONDARY outcome
Timeframe: 5 years from baseline (prosthetic loading)A surviving prosthesis is defined as still in place at the time of the follow-up.
Outcome measures
| Measure |
Short Implants
n=13 Participants
A full-arch screw-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm)
|
Long Implants
n=14 Participants
A full-arch srew-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal long implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
|
|---|---|---|
|
Prosthesis Survival
|
13 Prostheses
|
14 Prostheses
|
SECONDARY outcome
Timeframe: 5 years from baseline (prosthetic loading)Peri-implant mucositis and peri-implantitis
Outcome measures
| Measure |
Short Implants
n=13 Participants
A full-arch screw-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm)
|
Long Implants
n=14 Participants
A full-arch srew-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal long implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
|
|---|---|---|
|
Biological Complications
|
2 Participants
|
3 Participants
|
SECONDARY outcome
Timeframe: 5 years from baseline (prosthetic loading)Technical complications are categorized in minor and major complications. The formers require only chair-side repair and include screw loosening and veneer material fracture. The latters require additional laboratory procedures and/or replacement components and include prosthesis or framework fracture, screw fracture, implant fracture, and extended wear requiring veneer renewal.
Outcome measures
| Measure |
Short Implants
n=13 Participants
A full-arch screw-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: 6 mm)
|
Long Implants
n=14 Participants
A full-arch srew-retained mandibular prosthesis with distal cantilevers supported by five interforaminal short implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm: Rehabilitation of the edentulous mandible by a full-arch srew-retained prosthesis with distal cantilevers supported by five interforaminal long implants (ASTRA TECH Implant System, OsseoSpeed™ 4.0 S, length: ≥11mm)
|
|---|---|---|
|
Technical Complications
|
7 Participants
|
5 Participants
|
Adverse Events
Short Implants
Long Implants
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Prof. Marco Annunziata
University of Campania "Luigi Vanvitelli"
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place