Trial Outcomes & Findings for The Videolaryngoscopy in Small Infants (NCT NCT03396432)

NCT ID: NCT03396432

Last Updated: 2021-03-25

Results Overview

comparing the tracheal intubation (TI) first attempt success rate using VL vs. DL

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

566 participants

Primary outcome timeframe

at the time of intubation

Results posted on

2021-03-25

Participant Flow

The study was recruited per protocol without any protocol deviation or violation.

The block size was varying among 2, 4, 6 to avoid the predictability of device assignment. To further balance device assignment, we'll stratify the randomization by study site and clinician's role. Separate randomization schedule was generated for each stratum.

Participant milestones

Participant milestones
Measure
Video Laryngoscopy for Endotracheal (ET) Placement
Device: Storz C-MAC Video Laryngoscope Video Laryngoscopy for ET placement: Tracheal intubation performed with the Storz C-Mac Video Laryngoscope Direct Laryngoscopy for ET Placement: Tracheal Intubation performed with the Miller Blade
Direct Laryngoscopy for ET Placement
Device: Miller Laryngoscope Video Laryngoscopy for ET placement: Tracheal intubation performed with the Storz C-Mac Video Laryngoscope Direct Laryngoscopy for ET Placement: Tracheal Intubation performed with the Miller Blade
Overall Study
STARTED
283
283
Overall Study
COMPLETED
274
277
Overall Study
NOT COMPLETED
9
6

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Race and Ethnicity were not collected from any participant.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Video Laryngoscopy for Endotracheal (ET) Placement
n=274 Participants
Device: Storz C-MAC Video Laryngoscope Video Laryngoscopy for ET placement: Tracheal intubation performed with the Storz C-Mac Video Laryngoscope Direct Laryngoscopy for ET Placement: Tracheal Intubation performed with the Miller Blade
Direct Laryngoscopy for ET Placement
n=277 Participants
Device: Miller Laryngoscope Video Laryngoscopy for ET placement: Tracheal intubation performed with the Storz C-Mac Video Laryngoscope Direct Laryngoscopy for ET Placement: Tracheal Intubation performed with the Miller Blade
Total
n=551 Participants
Total of all reporting groups
Age, Customized
0-30 Days
17 Participants
n=274 Participants
20 Participants
n=277 Participants
37 Participants
n=551 Participants
Age, Customized
31-90 Days
55 Participants
n=274 Participants
64 Participants
n=277 Participants
119 Participants
n=551 Participants
Age, Customized
> 90 Days
202 Participants
n=274 Participants
193 Participants
n=277 Participants
395 Participants
n=551 Participants
Sex: Female, Male
Female
79 Participants
n=274 Participants
96 Participants
n=277 Participants
175 Participants
n=551 Participants
Sex: Female, Male
Male
195 Participants
n=274 Participants
181 Participants
n=277 Participants
376 Participants
n=551 Participants
Race and Ethnicity Not Collected
0 Participants
Race and Ethnicity were not collected from any participant.
Weight (kg)
6.5 kg
n=274 Participants
6.6 kg
n=277 Participants
6.5 kg
n=551 Participants
ASA
1 - Normal
58 Participants
n=274 Participants
72 Participants
n=277 Participants
130 Participants
n=551 Participants
ASA
2 - Mild systemic disease
133 Participants
n=274 Participants
136 Participants
n=277 Participants
269 Participants
n=551 Participants
ASA
>= 2 - Mod - Severe systemic disease
83 Participants
n=274 Participants
69 Participants
n=277 Participants
152 Participants
n=551 Participants
Induction Technique -IV
28 Participants
n=274 Participants
39 Participants
n=277 Participants
67 Participants
n=551 Participants
Muscle Relaxant
None
15 Participants
n=274 Participants
14 Participants
n=277 Participants
29 Participants
n=551 Participants
Muscle Relaxant
Succinylcholine
9 Participants
n=274 Participants
11 Participants
n=277 Participants
20 Participants
n=551 Participants
Muscle Relaxant
Other
250 Participants
n=274 Participants
252 Participants
n=277 Participants
502 Participants
n=551 Participants
Device experience as number of infant intubations
0
38 Participants
n=274 Participants
10 Participants
n=277 Participants
48 Participants
n=551 Participants
Device experience as number of infant intubations
1-10
79 Participants
n=274 Participants
59 Participants
n=277 Participants
138 Participants
n=551 Participants
Device experience as number of infant intubations
11-20
36 Participants
n=274 Participants
36 Participants
n=277 Participants
72 Participants
n=551 Participants
Device experience as number of infant intubations
21-50
49 Participants
n=274 Participants
37 Participants
n=277 Participants
86 Participants
n=551 Participants
Device experience as number of infant intubations
>50
62 Participants
n=274 Participants
128 Participants
n=277 Participants
190 Participants
n=551 Participants
Device experience as number of infant intubations
Unknown
10 Participants
n=274 Participants
7 Participants
n=277 Participants
17 Participants
n=551 Participants
Provider Role
Anes Attending
69 Participants
n=274 Participants
69 Participants
n=277 Participants
138 Participants
n=551 Participants
Provider Role
Anes Fellow
99 Participants
n=274 Participants
102 Participants
n=277 Participants
201 Participants
n=551 Participants
Provider Role
Anes Resident
106 Participants
n=274 Participants
106 Participants
n=277 Participants
212 Participants
n=551 Participants

PRIMARY outcome

Timeframe: at the time of intubation

comparing the tracheal intubation (TI) first attempt success rate using VL vs. DL

Outcome measures

Outcome measures
Measure
Video Laryngoscopy for Endotracheal (ET) Placement
n=274 Participants
Device: Storz C-MAC Video Laryngoscope Video Laryngoscopy for ET placement: Tracheal intubation performed with the Storz C-Mac Video Laryngoscope Direct Laryngoscopy for ET Placement: Tracheal Intubation performed with the Miller Blade
Direct Laryngoscopy for ET Placement
n=277 Participants
Device: Miller Laryngoscope Video Laryngoscopy for ET placement: Tracheal intubation performed with the Storz C-Mac Video Laryngoscope Direct Laryngoscopy for ET Placement: Tracheal Intubation performed with the Miller Blade
Number of Participants With Success in the First Attempt
253 Participants
243 Participants

SECONDARY outcome

Timeframe: At the time of intubation

Comparing the lowest oxygen saturation during tracheal intubation with VL vs. DL

Outcome measures

Outcome measures
Measure
Video Laryngoscopy for Endotracheal (ET) Placement
n=274 Participants
Device: Storz C-MAC Video Laryngoscope Video Laryngoscopy for ET placement: Tracheal intubation performed with the Storz C-Mac Video Laryngoscope Direct Laryngoscopy for ET Placement: Tracheal Intubation performed with the Miller Blade
Direct Laryngoscopy for ET Placement
n=277 Participants
Device: Miller Laryngoscope Video Laryngoscopy for ET placement: Tracheal intubation performed with the Storz C-Mac Video Laryngoscope Direct Laryngoscopy for ET Placement: Tracheal Intubation performed with the Miller Blade
Hypoxia
9 Participants
15 Participants

Adverse Events

Video Laryngoscopy for Endotracheal (ET) Placement

Serious events: 0 serious events
Other events: 3 other events
Deaths: 0 deaths

Direct Laryngoscopy for ET Placement

Serious events: 0 serious events
Other events: 2 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Other adverse events
Measure
Video Laryngoscopy for Endotracheal (ET) Placement
n=274 participants at risk
Device: Storz C-MAC Video Laryngoscope Video Laryngoscopy for ET placement: Tracheal intubation performed with the Storz C-Mac Video Laryngoscope
Direct Laryngoscopy for ET Placement
n=277 participants at risk
Device: Miller Laryngoscope Direct Laryngoscopy for ET Placement: Tracheal Intubation performed with the Miller Blade
Respiratory, thoracic and mediastinal disorders
Stridor
0.00%
0/274 • Upon discharge from PACU or up to 24 hr after intubation
0.36%
1/277 • Number of events 1 • Upon discharge from PACU or up to 24 hr after intubation
Cardiac disorders
Intermittent tachypnea
0.36%
1/274 • Number of events 1 • Upon discharge from PACU or up to 24 hr after intubation
0.00%
0/277 • Upon discharge from PACU or up to 24 hr after intubation
Respiratory, thoracic and mediastinal disorders
Brief Desaturation
0.73%
2/274 • Number of events 3 • Upon discharge from PACU or up to 24 hr after intubation
0.36%
1/277 • Number of events 1 • Upon discharge from PACU or up to 24 hr after intubation

Additional Information

Dr. John Fiadjoe, PI

Children Hospital of Philadelphia

Phone: 267-426-2961

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place