Correlation of ETCO2 to PaCO2 Measured by Sentri Nasal Cannula
NCT ID: NCT03374644
Last Updated: 2017-12-15
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
40 participants
INTERVENTIONAL
2018-01-15
2018-08-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Standard monitoring with continuous electrography (ECG), non-invasive blood pressure(NIBP) monitoring and pulse oximetry will be used for all patients. A baseline blood pressure, heart rate, respiratory rate, oxygen saturation (SaO2) and ETCO2 will be recorded. During preoperative period, a 20-gauge, radial artery catheter was inserted under aseptic technique. It is used to obtain arterial blood gas measurement of partial pressure oxygen and carbon dioxide (PaO2, PaCO2) Blood gas will be analyzed by using ABL 800 flex blood gas analyzer (Radiometer Medical ApS, Denmark) with calibrations recommended by the manufacturer. No sedation will be given during preoperative period.
Following the placement of indwelling radial artery catheter, Sentri nasal cannula will be placed into the nostril of the patients Subjects will be asked to breath normally for a period of five minutes . Nasal breathing will be confirmed by presence of an acceptable CO2 tracing.Blood is drawn from indwelling arterial catheter for blood gas determination 5 minutes after the modified nasal cannulae is in place. At the same time as the arterial blood gas sample is taken, an ETCO2 sample is also obtained. A baseline (without oxygen flow) ETCO2, PaO2, SPO2, respiratory rate and PaCO2 will be recorded. The respiratory rate will be determined by counting the respiration for 15 seconds and multiplying by four. Subjects will not be asked to keep their mouth close when using the nasal cannula as it might alter the variability inherent in patients who mouth breathe during conscious sedation. After a baseline ETCO2 is established, oxygen will be administered at 2,4, and 6 liters per minute for a period of five minutes. At each level of oxygen administration, an average ETC02 reading will be recorded after achieving stable recordings. Simultaneously, PaO2 and PaCO2 will be obtained by drawing arterial blood from arterial indwelling catheter. Heart rate, respiratory rate, blood pressure will also be routinely recorded.
Sedation will be given to the patients intraoperatively. Riker Sedation-Agitation Scale (SAS) will be used to assess the level of sedation during intraoperative period. Titrated dose of midazolam will be given to the patient with the target of SAS score of 3 (difficult to arouse but awakens to verbal stimuli or gentle shaking, follow simple commands but drifts off again). During intraoperative period, oxygen will be administered at 2 and 4 liters per minutes for a period of five minutes. ETCO2, PaCO2 and PaO2 level will be recorded during each level of oxygen administration.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
ETCO2 monitoring with nasal cannula
SentriTM ETCO2 adult nasal cannula (Intersurgical ® code 1144002) will be placed into patient's nostril following radial artery catheter insertion. A baseline (without oxygen flow) ETCO2, PaO2, SPO2, RR and PaCO2 will be recorded. Oxygen will then be administered at 2,4, and 6 liters per minute for a period of five minutes.ETCO2, PaCO2 and PaO2 will be recorded for each level of oxygen administration.Sedation will be given during intra-operative period with the target of Observer Assessment of alertness/sedation scale (OAA/S) score of 3. During intraoperative period, oxygen will be administered at 2 and 4 liters per minute for a period of five minutes. ETCO2, PaCO2 and PaO2 level will be recorded during each level of oxygen administration.
SentriTM ETCO2 adult nasal cannula
Sentri nasal cannula is the device which designed to sample exhaled ETCO2 in non-intubated patients during the administration of supplementary oxygen. By delivering oxygen through one prong and sampling exhaled gas from the other prong, the nasal cannula can provide end tidal values comparable to those achieved with intubated patients. It is fitted to the patients as same manner as conventional nasal cannula. Furthermore, it consists of curved prong to improve the anatomical fit.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
SentriTM ETCO2 adult nasal cannula
Sentri nasal cannula is the device which designed to sample exhaled ETCO2 in non-intubated patients during the administration of supplementary oxygen. By delivering oxygen through one prong and sampling exhaled gas from the other prong, the nasal cannula can provide end tidal values comparable to those achieved with intubated patients. It is fitted to the patients as same manner as conventional nasal cannula. Furthermore, it consists of curved prong to improve the anatomical fit.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Malaya
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Dr Lee Jia Wen
Medical officer
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2017925-5591
Identifier Type: -
Identifier Source: org_study_id