Trial Outcomes & Findings for Spectacles for Patients With Down Syndrome (NCT NCT03367793)
NCT ID: NCT03367793
Last Updated: 2021-10-25
Results Overview
Aided LogMAR distance visual acuity obtained with either the British Standard Letters or HOTV - matching for subjects unable to name letters.
COMPLETED
NA
30 participants
two months
2021-10-25
Participant Flow
Participant milestones
| Measure |
Clinical, Then Metric #1, Then Metric #2
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #1, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Clinical, Then Metric #2, Then Metric #1
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #2, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Clinical, Then Metric #2
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the clinically derived, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Clinical, Then Metric #1
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the clinically derived, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Metric #2, Then Clinical
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the metric-derived #2, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Metric #1, Then Clinical
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the metric-derived #1, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
|---|---|---|---|---|---|---|
|
Initial Acuity at Dispense Visit (10min)
STARTED
|
5
|
5
|
5
|
5
|
5
|
5
|
|
Initial Acuity at Dispense Visit (10min)
COMPLETED
|
5
|
5
|
5
|
5
|
5
|
5
|
|
Initial Acuity at Dispense Visit (10min)
NOT COMPLETED
|
0
|
0
|
0
|
0
|
0
|
0
|
|
Treatment 1 Dispense to 2 Months Wear
STARTED
|
5
|
5
|
5
|
5
|
5
|
5
|
|
Treatment 1 Dispense to 2 Months Wear
COMPLETED
|
5
|
5
|
5
|
5
|
5
|
5
|
|
Treatment 1 Dispense to 2 Months Wear
NOT COMPLETED
|
0
|
0
|
0
|
0
|
0
|
0
|
|
Treatment 2 Dispense to 2 Months Wear
STARTED
|
5
|
5
|
5
|
5
|
5
|
5
|
|
Treatment 2 Dispense to 2 Months Wear
COMPLETED
|
5
|
5
|
4
|
5
|
5
|
5
|
|
Treatment 2 Dispense to 2 Months Wear
NOT COMPLETED
|
0
|
0
|
1
|
0
|
0
|
0
|
|
Treatment 3 Dispense to 2 Months Wear
STARTED
|
5
|
5
|
5
|
5
|
5
|
5
|
|
Treatment 3 Dispense to 2 Months Wear
COMPLETED
|
5
|
5
|
5
|
5
|
5
|
5
|
|
Treatment 3 Dispense to 2 Months Wear
NOT COMPLETED
|
0
|
0
|
0
|
0
|
0
|
0
|
Reasons for withdrawal
| Measure |
Clinical, Then Metric #1, Then Metric #2
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #1, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Clinical, Then Metric #2, Then Metric #1
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #2, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Clinical, Then Metric #2
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the clinically derived, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Clinical, Then Metric #1
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the clinically derived, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Metric #2, Then Clinical
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the metric-derived #2, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Metric #1, Then Clinical
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the metric-derived #1, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
|---|---|---|---|---|---|---|
|
Treatment 2 Dispense to 2 Months Wear
Physician Decision
|
0
|
0
|
1
|
0
|
0
|
0
|
Baseline Characteristics
Spectacles for Patients With Down Syndrome
Baseline characteristics by cohort
| Measure |
Clinical, Then Metric #1, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #1, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Clinical, Then Metric #2, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #2, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Clinical, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the clinically derived, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Clinical, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the clinically derived, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Metric #2, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the metric-derived #2, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Metric #1, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the metric-derived #1, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Total
n=30 Participants
Total of all reporting groups
|
|---|---|---|---|---|---|---|---|
|
Age, Continuous
|
32 years
STANDARD_DEVIATION 9 • n=5 Participants
|
30 years
STANDARD_DEVIATION 13 • n=7 Participants
|
34 years
STANDARD_DEVIATION 9 • n=5 Participants
|
28 years
STANDARD_DEVIATION 12 • n=4 Participants
|
24 years
STANDARD_DEVIATION 4 • n=21 Participants
|
28 years
STANDARD_DEVIATION 10 • n=8 Participants
|
29 years
STANDARD_DEVIATION 10 • n=8 Participants
|
|
Sex: Female, Male
Female
|
3 Participants
n=5 Participants
|
1 Participants
n=7 Participants
|
3 Participants
n=5 Participants
|
1 Participants
n=4 Participants
|
3 Participants
n=21 Participants
|
4 Participants
n=8 Participants
|
15 Participants
n=8 Participants
|
|
Sex: Female, Male
Male
|
2 Participants
n=5 Participants
|
4 Participants
n=7 Participants
|
2 Participants
n=5 Participants
|
4 Participants
n=4 Participants
|
2 Participants
n=21 Participants
|
1 Participants
n=8 Participants
|
15 Participants
n=8 Participants
|
|
Ethnicity (NIH/OMB)
Hispanic or Latino
|
1 Participants
n=5 Participants
|
1 Participants
n=7 Participants
|
1 Participants
n=5 Participants
|
1 Participants
n=4 Participants
|
1 Participants
n=21 Participants
|
2 Participants
n=8 Participants
|
7 Participants
n=8 Participants
|
|
Ethnicity (NIH/OMB)
Not Hispanic or Latino
|
4 Participants
n=5 Participants
|
4 Participants
n=7 Participants
|
4 Participants
n=5 Participants
|
4 Participants
n=4 Participants
|
4 Participants
n=21 Participants
|
3 Participants
n=8 Participants
|
23 Participants
n=8 Participants
|
|
Ethnicity (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
0 Participants
n=4 Participants
|
0 Participants
n=21 Participants
|
0 Participants
n=8 Participants
|
0 Participants
n=8 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
0 Participants
n=4 Participants
|
0 Participants
n=21 Participants
|
0 Participants
n=8 Participants
|
0 Participants
n=8 Participants
|
|
Race (NIH/OMB)
Asian
|
0 Participants
n=5 Participants
|
1 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
0 Participants
n=4 Participants
|
0 Participants
n=21 Participants
|
0 Participants
n=8 Participants
|
1 Participants
n=8 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
0 Participants
n=4 Participants
|
0 Participants
n=21 Participants
|
0 Participants
n=8 Participants
|
0 Participants
n=8 Participants
|
|
Race (NIH/OMB)
Black or African American
|
2 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
1 Participants
n=4 Participants
|
0 Participants
n=21 Participants
|
1 Participants
n=8 Participants
|
4 Participants
n=8 Participants
|
|
Race (NIH/OMB)
White
|
3 Participants
n=5 Participants
|
3 Participants
n=7 Participants
|
5 Participants
n=5 Participants
|
3 Participants
n=4 Participants
|
5 Participants
n=21 Participants
|
4 Participants
n=8 Participants
|
23 Participants
n=8 Participants
|
|
Race (NIH/OMB)
More than one race
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
1 Participants
n=4 Participants
|
0 Participants
n=21 Participants
|
0 Participants
n=8 Participants
|
1 Participants
n=8 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=5 Participants
|
1 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
0 Participants
n=4 Participants
|
0 Participants
n=21 Participants
|
0 Participants
n=8 Participants
|
1 Participants
n=8 Participants
|
|
Region of Enrollment
United States
|
5 participants
n=5 Participants
|
5 participants
n=7 Participants
|
5 participants
n=5 Participants
|
5 participants
n=4 Participants
|
5 participants
n=21 Participants
|
5 participants
n=8 Participants
|
30 participants
n=8 Participants
|
|
Adaptive Behavior Standard Score
|
74 Standard Score
n=5 Participants
|
73 Standard Score
n=7 Participants
|
59 Standard Score
n=5 Participants
|
60 Standard Score
n=4 Participants
|
57 Standard Score
n=21 Participants
|
59 Standard Score
n=8 Participants
|
60 Standard Score
n=8 Participants
|
|
Binocular Distance Visual Acuity
|
0.30 logMAR
STANDARD_DEVIATION .10 • n=5 Participants
|
0.48 logMAR
STANDARD_DEVIATION 0.29 • n=7 Participants
|
0.40 logMAR
STANDARD_DEVIATION 0.13 • n=5 Participants
|
0.38 logMAR
STANDARD_DEVIATION 0.15 • n=4 Participants
|
0.46 logMAR
STANDARD_DEVIATION 0.16 • n=21 Participants
|
0.30 logMAR
STANDARD_DEVIATION 0.14 • n=8 Participants
|
0.39 logMAR
STANDARD_DEVIATION 0.17 • n=8 Participants
|
|
Number presenting with spectacles
|
4 Participants
n=5 Participants
|
4 Participants
n=7 Participants
|
3 Participants
n=5 Participants
|
4 Participants
n=4 Participants
|
2 Participants
n=21 Participants
|
4 Participants
n=8 Participants
|
21 Participants
n=8 Participants
|
|
Refractive Error Classification
Myopia
|
5 Number of Eyes
n=5 Participants
|
1 Number of Eyes
n=7 Participants
|
4 Number of Eyes
n=5 Participants
|
1 Number of Eyes
n=4 Participants
|
8 Number of Eyes
n=21 Participants
|
4 Number of Eyes
n=8 Participants
|
23 Number of Eyes
n=8 Participants
|
|
Refractive Error Classification
Hyperopia
|
4 Number of Eyes
n=5 Participants
|
6 Number of Eyes
n=7 Participants
|
3 Number of Eyes
n=5 Participants
|
4 Number of Eyes
n=4 Participants
|
1 Number of Eyes
n=21 Participants
|
3 Number of Eyes
n=8 Participants
|
21 Number of Eyes
n=8 Participants
|
|
Refractive Error Classification
Mixed Astigmatism
|
1 Number of Eyes
n=5 Participants
|
3 Number of Eyes
n=7 Participants
|
3 Number of Eyes
n=5 Participants
|
5 Number of Eyes
n=4 Participants
|
0 Number of Eyes
n=21 Participants
|
3 Number of Eyes
n=8 Participants
|
15 Number of Eyes
n=8 Participants
|
|
Refractive Error Classification
Emmetropia
|
0 Number of Eyes
n=5 Participants
|
0 Number of Eyes
n=7 Participants
|
0 Number of Eyes
n=5 Participants
|
0 Number of Eyes
n=4 Participants
|
1 Number of Eyes
n=21 Participants
|
0 Number of Eyes
n=8 Participants
|
1 Number of Eyes
n=8 Participants
|
|
Autorefraction Spherical Equivalent OD
|
-1.68 Diopters
STANDARD_DEVIATION 4.53 • n=5 Participants
|
1.93 Diopters
STANDARD_DEVIATION 3.07 • n=7 Participants
|
-3.73 Diopters
STANDARD_DEVIATION 7.33 • n=5 Participants
|
0.98 Diopters
STANDARD_DEVIATION 1.27 • n=4 Participants
|
-1.75 Diopters
STANDARD_DEVIATION 4.37 • n=21 Participants
|
-5.23 Diopters
STANDARD_DEVIATION 4.75 • n=8 Participants
|
-1.58 Diopters
STANDARD_DEVIATION 4.88 • n=8 Participants
|
|
Autorefraction Spherical Equivalent OS
|
-2.03 Diopters
STANDARD_DEVIATION 5.91 • n=5 Participants
|
1.95 Diopters
STANDARD_DEVIATION 2.52 • n=7 Participants
|
-2.68 Diopters
STANDARD_DEVIATION 6.81 • n=5 Participants
|
-0.05 Diopters
STANDARD_DEVIATION 2.43 • n=4 Participants
|
-1.58 Diopters
STANDARD_DEVIATION 4.55 • n=21 Participants
|
-3.53 Diopters
STANDARD_DEVIATION 3.73 • n=8 Participants
|
-1.32 Diopters
STANDARD_DEVIATION 4.59 • n=8 Participants
|
|
Autorefraction Cylinder OD
|
-1.45 Diopters
STANDARD_DEVIATION 0.67 • n=5 Participants
|
-3.65 Diopters
STANDARD_DEVIATION 1.43 • n=7 Participants
|
-2.65 Diopters
STANDARD_DEVIATION 2.91 • n=5 Participants
|
-2.25 Diopters
STANDARD_DEVIATION 1.08 • n=4 Participants
|
-1.50 Diopters
STANDARD_DEVIATION 0.68 • n=21 Participants
|
-1.35 Diopters
STANDARD_DEVIATION 0.68 • n=8 Participants
|
-2.14 Diopters
STANDARD_DEVIATION 1.58 • n=8 Participants
|
|
Autorefraction Cylinder OS
|
-1.15 Diopters
STANDARD_DEVIATION 0.68 • n=5 Participants
|
-3.60 Diopters
STANDARD_DEVIATION 1.32 • n=7 Participants
|
-1.55 Diopters
STANDARD_DEVIATION 1.81 • n=5 Participants
|
-2.10 Diopters
STANDARD_DEVIATION 0.42 • n=4 Participants
|
-1.95 Diopters
STANDARD_DEVIATION 1.45 • n=21 Participants
|
-2.05 Diopters
STANDARD_DEVIATION 0.37 • n=8 Participants
|
-2.07 Diopters
STANDARD_DEVIATION 1.30 • n=8 Participants
|
PRIMARY outcome
Timeframe: two monthsPopulation: Spectacles from the clinical treatment method were not dispensed to one participant in the Metric #1, then Clinical, then Metric #2 group due to failure of the safety criteria required for dispense. This spectacle prescription resulted in visual acuity worse than 7 letters from the participant's presenting acuity to the study.
Aided LogMAR distance visual acuity obtained with either the British Standard Letters or HOTV - matching for subjects unable to name letters.
Outcome measures
| Measure |
Clinical, Then Metric #1, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #1, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Clinical, Then Metric #2, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #2, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Clinical, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the clinically derived, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Clinical, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the clinically derived, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Metric #2, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the metric-derived #2, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Metric #1, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the metric-derived #1, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
|---|---|---|---|---|---|---|
|
Adapted Visual Acuity
Period 2 Treatment 1 Dispense to 2 Months Wear
|
0.256 logMAR
Standard Deviation 0.110
|
0.440 logMAR
Standard Deviation 0.240
|
0.356 logMAR
Standard Deviation 0.149
|
0.284 logMAR
Standard Deviation 0.089
|
0.300 logMAR
Standard Deviation 0.163
|
0.364 logMAR
Standard Deviation 0.048
|
|
Adapted Visual Acuity
Period 3 Treatment 2 Dispense to 2 Months Wear
|
0.272 logMAR
Standard Deviation 0.135
|
0.412 logMAR
Standard Deviation 0.215
|
0.370 logMAR
Standard Deviation 0.093
|
0.316 logMAR
Standard Deviation 0.157
|
0.256 logMAR
Standard Deviation 0.344
|
0.316 logMAR
Standard Deviation 0.091
|
|
Adapted Visual Acuity
Period 4 Treatment 3 Dispense to 2 Months Wear
|
0.288 logMAR
Standard Deviation 0.100
|
0.424 logMAR
Standard Deviation 00.238
|
0.320 logMAR
Standard Deviation 0.117
|
0.276 logMAR
Standard Deviation 0.140
|
0.216 logMAR
Standard Deviation 0.119
|
0.372 logMAR
Standard Deviation 0.091
|
SECONDARY outcome
Timeframe: 1 dayAided LogMAR distance visual acuity obtained with either the British Standard Letters or HOTV - matching for subjects unable to name letters.
Outcome measures
| Measure |
Clinical, Then Metric #1, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #1, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Clinical, Then Metric #2, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #2, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Clinical, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the clinically derived, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Clinical, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the clinically derived, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Metric #2, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the metric-derived #2, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Metric #1, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the metric-derived #1, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
|---|---|---|---|---|---|---|
|
Initial Visual Acuity
Treatment 1 Initial Dispense
|
0.28 logMAR
Standard Deviation 0.14
|
0.43 logMAR
Standard Deviation 0.25
|
0.34 logMAR
Standard Deviation 0.22
|
0.28 logMAR
Standard Deviation 0.13
|
0.29 logMAR
Standard Deviation 0.35
|
0.33 logMAR
Standard Deviation 0.09
|
|
Initial Visual Acuity
Treatment 2 Initial Dispense
|
0.25 logMAR
Standard Deviation 0.08
|
0.43 logMAR
Standard Deviation 0.25
|
0.36 logMAR
Standard Deviation 0.18
|
0.30 logMAR
Standard Deviation 0.22
|
0.30 logMAR
Standard Deviation 0.15
|
0.34 logMAR
Standard Deviation 0.07
|
|
Initial Visual Acuity
Treatment 3 Initial Dispense
|
0.31 logMAR
Standard Deviation 0.40
|
0.44 logMAR
Standard Deviation 0.24
|
0.40 logMAR
Standard Deviation 0.16
|
0.32 logMAR
Standard Deviation 0.18
|
0.28 logMAR
Standard Deviation 0.14
|
0.40 logMAR
Standard Deviation 0.05
|
SECONDARY outcome
Timeframe: two monthsPopulation: For Period 3, one participant in group Metric #1, then Clinical, then Metric #2 did not receive the Clinical spectacle treatment because it failed the safety criteria for dispense. The clinical treatment for that participant reduced visual acuity greater than 7 letters from presenting acuity.
Total wear time of each pair of spectacles as measured objectively by a temperature sensor data logger mounted to the spectacle temple.
Outcome measures
| Measure |
Clinical, Then Metric #1, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #1, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Clinical, Then Metric #2, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #2, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Clinical, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the clinically derived, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Clinical, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the clinically derived, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Metric #2, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the metric-derived #2, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Metric #1, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the metric-derived #1, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
|---|---|---|---|---|---|---|
|
Spectacle Wear Time
Period 4 Treatment 3 Dispense to 2 Months Wear
|
11.61 Hours
Standard Deviation 6.05
|
13.32 Hours
Standard Deviation 4.53
|
11.95 Hours
Standard Deviation 4.18
|
9.47 Hours
Standard Deviation 5.12
|
9.54 Hours
Standard Deviation 4.34
|
11.31 Hours
Standard Deviation 3.06
|
|
Spectacle Wear Time
Period 2 Treatment 1 Dispense to 2 Months Wear
|
11.93 Hours
Standard Deviation 4.95
|
13.15 Hours
Standard Deviation 3.96
|
10.48 Hours
Standard Deviation 4.08
|
9.81 Hours
Standard Deviation 4.32
|
8.40 Hours
Standard Deviation 4.29
|
11.62 Hours
Standard Deviation 2.55
|
|
Spectacle Wear Time
Period 3 Treatment 2 Dispense to 2 Months Wear
|
9.50 Hours
Standard Deviation 5.50
|
12.68 Hours
Standard Deviation 5.82
|
12.31 Hours
Standard Deviation 4.74
|
9.67 Hours
Standard Deviation 4.85
|
9.26 Hours
Standard Deviation 4.17
|
11.25 Hours
Standard Deviation 2.96
|
SECONDARY outcome
Timeframe: two monthsPopulation: A single participant from group 'Metric #1, then Clinical, then Metric #2' was not dispensed the clinical treatment due to the treatment failing one of the safety criteria for dispense.
Participants were asked to select a face from a survey with five expressions (large frown, small frown, neutral, small smile, large smile) depicting their response to the question 'Do you like wearing this pair of glasses?' Responses were coded 1 through 5 with 5 = large smile.
Outcome measures
| Measure |
Clinical, Then Metric #1, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #1, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Clinical, Then Metric #2, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #2, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Clinical, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the clinically derived, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Clinical, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the clinically derived, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Metric #2, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the metric-derived #2, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Metric #1, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the metric-derived #1, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
|---|---|---|---|---|---|---|
|
Spectacle Assessment Survey Question 1
Period 2 Treatment 1 Dispense to 2 Months Wear
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 2.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
|
Spectacle Assessment Survey Question 1
Period 3 Treatment 2 Dispense to 2 Months Wear
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
4 score on a scale
Interval 4.0 to 5.0
|
|
Spectacle Assessment Survey Question 1
Period 4 Treatment 3 Dispense to 2 Months Wear
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
4 score on a scale
Interval 4.0 to 5.0
|
SECONDARY outcome
Timeframe: two monthsPopulation: A single participant from group 'Metric #1, then Clinical, then Metric #2' was not dispensed the clinical treatment due to the treatment failing one of the safety criteria for dispense.
Participants were asked to select a face from a survey with five expressions (large frown, small frown, neutral, small smile, large smile) depicting their response to the question 'How well do you see with this pair of glasses when looking far away?' Responses were coded 1 through 5 with 5 = large smile.
Outcome measures
| Measure |
Clinical, Then Metric #1, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #1, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Clinical, Then Metric #2, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #2, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Clinical, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the clinically derived, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Clinical, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the clinically derived, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Metric #2, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the metric-derived #2, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Metric #1, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the metric-derived #1, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
|---|---|---|---|---|---|---|
|
Spectacle Assessment Survey Question 2
Period 2 Treatment 1 Dispense to 2 Months Wear
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
|
Spectacle Assessment Survey Question 2
Period 3 Treatment 2 Dispense to 2 Months Wear
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
4.5 score on a scale
Interval 4.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
4 score on a scale
Interval 4.0 to 5.0
|
|
Spectacle Assessment Survey Question 2
Period 4 Treatment 3 Dispense to 2 Months Wear
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
SECONDARY outcome
Timeframe: two monthsPopulation: A single participant from group 'Metric #1, then Clinical, then Metric #2' was not dispensed the clinical treatment due to the treatment failing one of the safety criteria for dispense.
Participants were asked to select a face from a survey with five expressions (large frown, small frown, neutral, small smile, large smile) depicting their response to the question 'How well do you see with this pair of glasses when looking up close?' Responses were coded 1 through 5 with 5 = large smile.
Outcome measures
| Measure |
Clinical, Then Metric #1, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #1, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Clinical, Then Metric #2, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the clinically derived prescription first, followed by the metric-derived #2, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Clinical, Then Metric #2
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the clinically derived, and lastly the metric-derived #2.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Clinical, Then Metric #1
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the clinically derived, and lastly the metric-derived #1.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #1, Then Metric #2, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #1 prescription first, followed by the metric-derived #2, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
Metric #2, Then Metric #1, Then Clinical
n=5 Participants
Subjects will receive all three spectacle prescription interventions dispensed in randomized order for 2 months of wear each. Subjects in this arm of the study will receive the metric-derived #2 prescription first, followed by the metric-derived #1, and lastly the clinically derived.
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
|---|---|---|---|---|---|---|
|
Spectacle Assessment Survey Question 3
Period 2 Treatment 1 Dispense to 2 Months Wear
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
|
Spectacle Assessment Survey Question 3
Period 3 Treatment 2 Dispense to 2 Months Wear
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 4.5 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
|
Spectacle Assessment Survey Question 3
Period 4 Treatment 3 Dispense to 2 Months Wear
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 5.0 to 5.0
|
5 score on a scale
Interval 4.0 to 5.0
|
Adverse Events
Clinical
Metric #1
Metric #2
Serious adverse events
Adverse event data not reported
Other adverse events
| Measure |
Clinical
n=29 participants at risk
Spectacles - Clinically Derived: Prescription spectacle lenses determined by clinically derived techniques of a masked examiner and may include autorefraction, retinoscopy, and subjective refraction obtained pre or post dilation.
|
Metric #1
n=30 participants at risk
Spectacles - Metric Technique #1 Derived: For this method, wavefront error will be measured with the COAS (complete ophthalmic analysis system) wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Visual Strehl ratio in the spatial domain (VSX).
|
Metric #2
n=30 participants at risk
Spectacles - Metric Technique #2 Derived: For this method, wavefront error will be measured with the COAS wavefront aberrometer post-dilation (3 - 5 captures per eye). Measures will be re-sized to the patient's habitual pupil diameter and averaged. Post-measurement analysis is performed to identify the refractive correction predicted to produce the best image quality, as measured by maximization of the image quality metric Pupil Fraction tessellated (PFSt).
|
|---|---|---|---|
|
Eye disorders
Vision complaint related to comparison with earlier randomized treatment or habitual spectacles
|
24.1%
7/29 • Number of events 7 • Adverse event data were collected from the time of dispense of the first treatment through follow up of the final dispensed treatment (6 months total).
Parents/guardians of participants were contacted by phone one day and one week after each new treatment was dispensed to inquire whether participants were having any difficulty with the glasses. At every visit, participants and their family member were asked if there had been any medical or medication changes since the last visit and if they had any concerns about the spectacles or any new ocular or visual complaints. Reports of glasses needing a fit adjustment were not considered AEs.
|
3.3%
1/30 • Number of events 1 • Adverse event data were collected from the time of dispense of the first treatment through follow up of the final dispensed treatment (6 months total).
Parents/guardians of participants were contacted by phone one day and one week after each new treatment was dispensed to inquire whether participants were having any difficulty with the glasses. At every visit, participants and their family member were asked if there had been any medical or medication changes since the last visit and if they had any concerns about the spectacles or any new ocular or visual complaints. Reports of glasses needing a fit adjustment were not considered AEs.
|
6.7%
2/30 • Number of events 2 • Adverse event data were collected from the time of dispense of the first treatment through follow up of the final dispensed treatment (6 months total).
Parents/guardians of participants were contacted by phone one day and one week after each new treatment was dispensed to inquire whether participants were having any difficulty with the glasses. At every visit, participants and their family member were asked if there had been any medical or medication changes since the last visit and if they had any concerns about the spectacles or any new ocular or visual complaints. Reports of glasses needing a fit adjustment were not considered AEs.
|
|
Respiratory, thoracic and mediastinal disorders
Upper Respiratory Symptoms
|
0.00%
0/29 • Adverse event data were collected from the time of dispense of the first treatment through follow up of the final dispensed treatment (6 months total).
Parents/guardians of participants were contacted by phone one day and one week after each new treatment was dispensed to inquire whether participants were having any difficulty with the glasses. At every visit, participants and their family member were asked if there had been any medical or medication changes since the last visit and if they had any concerns about the spectacles or any new ocular or visual complaints. Reports of glasses needing a fit adjustment were not considered AEs.
|
13.3%
4/30 • Number of events 5 • Adverse event data were collected from the time of dispense of the first treatment through follow up of the final dispensed treatment (6 months total).
Parents/guardians of participants were contacted by phone one day and one week after each new treatment was dispensed to inquire whether participants were having any difficulty with the glasses. At every visit, participants and their family member were asked if there had been any medical or medication changes since the last visit and if they had any concerns about the spectacles or any new ocular or visual complaints. Reports of glasses needing a fit adjustment were not considered AEs.
|
6.7%
2/30 • Number of events 3 • Adverse event data were collected from the time of dispense of the first treatment through follow up of the final dispensed treatment (6 months total).
Parents/guardians of participants were contacted by phone one day and one week after each new treatment was dispensed to inquire whether participants were having any difficulty with the glasses. At every visit, participants and their family member were asked if there had been any medical or medication changes since the last visit and if they had any concerns about the spectacles or any new ocular or visual complaints. Reports of glasses needing a fit adjustment were not considered AEs.
|
Additional Information
Dr. Heather Anderson, Study PI
Ohio State University College of Optometry
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place