Development and Validation of Advanced MRI Methods for Clinical Applications

NCT ID: NCT03264300

Last Updated: 2021-09-21

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

220 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-06-26

Study Completion Date

2022-10-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

A critical aspect of brain tumor patient management is the radiographic assessment of tumor status, which is used for diagnosis, localization, surgical planning and surveillance. The primary goal is to develop and apply advanced, quantitative magnetic resonance imaging (MRI) techniques that can supplement existing high-resolution anatomic imaging to aid clinical decision-making for patients diagnosed with brain tumors. The studies proposed herein involve the development of advanced imaging methods that are intrinsically sensitive to the biophysical characteristics associated with tumor pathogenesis, as they are more likely to improve tumor characterization and localization and may offer early and more specific indicators of treatment response. These advanced methods include diffusion-weighted imaging (DWI), chemical exchange saturation transfer (CEST), and dynamic susceptibility contrast (DSC) perfusion MRI. A secondary objective of this study is to validate cerebral blood volume (CBV) metrics acquired using a DSC acquisition and post-processing methods by comparison with an intravascular reference standard contrast agent. Validated perfusion imaging techniques will improve the reliability and relevancy of derived CBV metrics across a range of clinical applications, including tumor localization, treatment guidance, therapy response assessment, surgical and biopsy guidance, and multi-site clinical trials of conventional and targeted brain tumor therapies.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The objectives of this study are to (1) Develop and optimize acquisition methods for MRI-based biomarkers that are indicative of brain tumor pathophysiology. These methods include, but are not limited to, DWI, CEST, and Dynamic Susceptibility Contrast (DSC) and Dynamic Contrast Enhanced (DCE) MRI; and (2) Validate DSC-MRI accuracy by comparison to an intravascular reference standard. Developmental studies: During the development of new imaging-based biomarkers, it is critical to optimize acquisition parameters, systematically characterize performance and contrast in the pathology of interest, validate with histopathology and establish test-retest repeatability. Thus, the first goal of this study is to develop advanced Diffusion Weighted Imaging (DWI), CEST and DSC/DCE-MRI methods for application to brain tumors. Objective 1 is a single-center study of up to 60 subjects being done to explore and optimize imaging signatures indicative of altered functional tumor states. These advanced imaging methods will allow the investigators to probe neuropathological tumor correlates, including cellular characteristics, molecular and metabolic changes, and vascular characteristics. Compared to existing conventional anatomic imaging, the researchers hypothesize that these experimental methods will be better able to characterize brain tumors and will have the potential to serve as new biomarkers of diagnostic and therapeutic importance. The researchers approach brings together biophysical and physiological information obtained from MRI and correlates this with clinical diagnoses and outcomes. Validation of DSC-MRI: Despite DSC-MRI's potential impact on clinical care, its broad scale integration has been slow, in large part from a lack of consensus about methodology and how to prevent potential CBV inaccuracies. Although DSC-MRI relies on the assumption that gadolinium-based contrast agents remain within the vascular lumen, this condition is often violated in vivo. If not corrected for, contrast agent leakage effects lead to CBV inaccuracy, misdiagnosis, and potentially mistreatment. While there exist numerous leakage correction strategies that have been shown to clearly improve DSC-MRI's clinical utility (e.g., predicting therapeutic response), a key limitation has prevented the standardization and wide-spread adoption of DSC-MRI methodology: To date, no study has validated the accuracy of leakage corrected CBV measures in patients. So while leakage corrected CBV values may be used, for example, to differentiate tumor recurrence from post-treatment effects, it is unknown whether this clinical benefit is a consequence of the complex combination of pulse sequence parameters, kinetics, dosing scheme, relaxivities, and leakage correction strategy or if the computed CBV actually reflects the underlying vascular density. This distinction is critical because it has implications for DSC-MRI standardization, establishing CBV thresholds for clinic use, multi-site comparisons and clinical trials. The investigators believe this limitation represents the most critical and clinically relevant challenge in the field of brain tumor DSC-MRI that urgently needs to be addressed. Objective 2 is a single-center study of up to 160 subjects being done to validate the accuracy of DSC-MRI measures of CBV. To validate the DSC-MRI measures derived from small molecular weight gadolinium-based (Gd) contrast agents, the investigators will compare rCBV maps to those derived from the intravascular contrast agent, Ferumoxytol. Ferumoxytol has been evaluated in humans as a potential DSC-MRI contrast agent but not for the purposes of validating leakage correction techniques. Since ferumoxytol-based DSC-MRI is not influenced by leakage effects, it enables the assessment of the most reliable perfusion metrics that can be expected from DSC-MRI and, as such, is the most reliable reference standard by which to evaluate CBV accuracy. Note that while ferumoxytol is undergoing clinical trials as a potential DSC-MRI contrast agent, it is unlikely to replace Gd-based contrast agents because it cannot provide the signal enhancement expected on conventional post-contrast T1-weighted images and is therefore unsuitable for use with standard response criteria.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Brain Tumor

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Development of advanced MRI methods

Subjects with brain tumor. Subjects may be scanned using a single time-point to permit development and optimization of advanced MRI methods. Subjects may be scanned up to two times, with both visits occurring within one month, to permit analysis of test-retest reliability/repeatability.

Group Type ACTIVE_COMPARATOR

MRI

Intervention Type OTHER

MRI scans to include: scout images, transmitter tuning, shimming, slice prescription - 5 min; conventional structural MRI; T1-weighted anatomic MRI scan - 7 min; and, T2-weighted anatomic MRI scan - 5 min. Advanced MRI to include: Diffusion Weighted MRI (DW-MRI) - 7 min; Chemical Exchange Saturation Transfer (CEST) - 9 min; Dynamic Susceptibility Contrast / Dynamic Contrast Enhanced MRI - 8 min; and, other advanced imaging, as needed, to be determined. Post-contrast conventional MRI to include T1-weighted anatomic MRI scan - 7 min. Repeat within 1 month.

Validation of rCBV accuracy

64 subjects with primary glioma and 96 subjects with recurrent glioma. Subjects will be scanned using a single time-point to validate rCBV accuracy.

Group Type ACTIVE_COMPARATOR

MRI

Intervention Type OTHER

MRI scans to include: scout images, transmitter tuning, shimming, slice prescription - 5 min. Conventional structural MRI to include: T1-weighted anatomic MRI scan - 7 min; and, T2-weighted anatomic MRI scan - 5 min. Serial DSC-MRI: staged injections of Gd-based contrast and Ferumoxytol - 20 min. Post-contrast conventional MRI: T1-weighted anatomic MRI scan - 7 min.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

MRI

MRI scans to include: scout images, transmitter tuning, shimming, slice prescription - 5 min; conventional structural MRI; T1-weighted anatomic MRI scan - 7 min; and, T2-weighted anatomic MRI scan - 5 min. Advanced MRI to include: Diffusion Weighted MRI (DW-MRI) - 7 min; Chemical Exchange Saturation Transfer (CEST) - 9 min; Dynamic Susceptibility Contrast / Dynamic Contrast Enhanced MRI - 8 min; and, other advanced imaging, as needed, to be determined. Post-contrast conventional MRI to include T1-weighted anatomic MRI scan - 7 min. Repeat within 1 month.

Intervention Type OTHER

MRI

MRI scans to include: scout images, transmitter tuning, shimming, slice prescription - 5 min. Conventional structural MRI to include: T1-weighted anatomic MRI scan - 7 min; and, T2-weighted anatomic MRI scan - 5 min. Serial DSC-MRI: staged injections of Gd-based contrast and Ferumoxytol - 20 min. Post-contrast conventional MRI: T1-weighted anatomic MRI scan - 7 min.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Must have either radiological or established histological diagnosis of the following: glioma / central nervous system (CNS) lymphoma / meningioma or brain metastases.
* Willing and able to provide written informed consent in compliance with the regulatory requirements. If a subject is unable to provide written informed consent, written informed consent may be obtained from the subject's legal representative.
* In the opinion of the investigator, able to fully participate in the study and sufficiently proficient in English to be capable of reliably completing study assessments.
* Sexually active women of child-bearing potential (Groups 1 and 2) and men (Group 2 only) must agree to use adequate methods to avoid pregnancy.

Exclusion Criteria

* Subjects who have a contraindication for MRI: presence of an incompatible bio-implants (e.g., pacemakers, neurostimulators, electronic infusion pumps, etc.), metal in their bodies (non-MRI compatible cerebral aneurysm clips, shrapnel, metallic fragments in or near the eyes as pertains to metal workers and machinists), or noticeable anxiety and/or claustrophobia and/or severe vertigo when moved into the magnet bore.
* Subjects who are pregnant or lactating or who suspect they might be pregnant.
* (Groups 1 and 2, subjects receiving intravenous gadolinium (Gd) contrast material). Subjects with renal insufficiency or known allergy to Gd-based contrast material.
* (Group 2 only) Subjects with known or suspected iron overload.
* (Group 2 only) Subjects with known allergic or hypersensitivity reactions to parenteral iron treatment or other intravenous iron products; subjects with significant drug or other allergies or autoimmune diseases may be enrolled at the investigator's discretion.
* Unwilling or unable to comply with the requirements of this protocol, including the presence of any condition (physical, mental, or social) that is likely to affect the subject's ability to comply with the protocol.
* Any other reasons that, in the opinion of the Investigator, the candidate is determined to be unsuitable for entry into the study.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Cancer Institute (NCI)

NIH

Sponsor Role collaborator

St. Joseph's Hospital and Medical Center, Phoenix

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Lisa Arnold

Research Operations Manager

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

C C Quarles, PhD

Role: PRINCIPAL_INVESTIGATOR

St. Joseph's Hospital and Medical Center, Phoenix

Ashley M Stokes, PhD

Role: PRINCIPAL_INVESTIGATOR

St. Joseph's Hospital and Medical Center, Phoenix

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

St. Joseph's Hospital and Medical Center

Phoenix, Arizona, United States

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Lisa Arnold, BS

Role: CONTACT

602-406-9593

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Lisa Arnold, BS

Role: primary

602-406-9593

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

1R01CA213158-01A1

Identifier Type: NIH

Identifier Source: secondary_id

View Link

PHXA-16-0235-10-08

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Multi-Parametric Brain Cancer MRI
NCT02649699 COMPLETED NA