Implementation and Evaluation of a Perceptual Learning Module on Visual Estimation of LVEF
NCT ID: NCT03245567
Last Updated: 2025-07-04
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
52 participants
INTERVENTIONAL
2018-07-06
2019-05-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
1. Implement a Web platform intended to host perceptual learning modules (PLMs)
2. Implement and assess a PLM designed to improve the capacity of first-year residents and fourth-year medical students to visually estimate the left ventricular ejection fraction (LVEF) with transesophageal echocardiography (TEE) images.
The hypothesis of the study is that the PLM will improve the visual assessment of LVEF by TEE in junior residents and medical students.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effectiveness of Simulation-based Training on Transoesophageal Echocardiography Learning
NCT05564507
Automated Left Ventricular Function Evaluation by LVivoEF
NCT01515267
Telesonography for Visually Estimating Ejection Fraction
NCT02960685
LVEF Prediction During ACS Using AI Algorithm Applied on Coronary Angiogram Videos
NCT05317286
Learning Curve CUSUM of LV Ejection Fraction by Visual Estimation in Novice Practitioners
NCT02866318
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Simulators have gained popularity as tools for teaching echocardiography, showing benefits mostly regarding probe handling and image acquisition. Some simulators may also be useful to replicate some diseases, but most simulators can only replicate a limited variety of diseases, and mostly typical presentations. This is an important limitation when it comes to teaching image interpretation. In order to develop their expertise, trainees have to be exposed to a wide range of normal variations and to more subtle abnormalities.
PLMs represent an alternative modality to teach image interpretation, and are already used in other fields. PLMs are online tools created to enhance the development of pattern recognition, a skill required to efficiently interpret TEE images. With PLMs, learners observe a series of images or videoclips and must answer a question about each image in a short period of time. Each answer is followed by an immediate feedback (the correct answer). By observing a large number of images online and by receiving systematic and expert feedback, the trainee quickly learns to extract efficiently the required information from the image.
This study will aim to evaluate the effects of a PLM on the ability of junior residents and medical students to correctly estimate visually the left ventricular ejection faction using TEE images.
Methods:
A team of experienced programmers will develop a Web platform, which will allow the identification of both participants and TEE experts, manage the consent process, host the tests used to assess the participants' expertise and the PLM itself, as well as manage the TEE images and the study data.
The pilot study designed to assess the impact of the PLM on the visual estimation of LVEF will be composed of the following steps:
1. selection and validation of TEE cases,
2. development of two versions of a test and of the PLM,
3. analysis of the impact of the PLM on participants' performance vs a control group.
Each TEE case used in this study will comprise 3 short video loops containing the following standardised echocardiographic views:
* midesophageal four chamber view
* midesophageal two chamber view
* midesophageal long axis view
Prior to inclusion in the study, each case will be anonymized and then validated by two cardiologists expert in TEE interpretation. Only cases where the visual estimation of the LVEF provided independently by the two TEE experts will differ by no more than 10% will be used. Two different sets of validated images will then be created.
The first set will be comprised of two groups of 20 validated cases (total of 40 cases). These cases will be used to create two versions of a test used to assess participants' expertise in the visual estimation of LVEF at different stages in the research protocol. These cases will not be part of the PLM.
The second set will be comprised of 96 validated cases destined to the PLM. The PLM is designed not to assess the participants' expertise, but to develop their ability to estimate LVEF.
When taking a test on the platform, participants will see the three short video loops of each case simultaneously on the screen for a maximum of 20 seconds, and will then have to provide an estimation of the LVEF. Each answer will be followed immediately by another case, and no feedback will be provided.
When doing the PLM, participants will see the three short video loops of each case simultaneously on the screen for a maximum of 20 seconds, and will then have to provide an estimation of the LVEF. However, each answer will be followed by feedback in the form of the average value of the experts' visual estimates of LVEF. This sequence of "case visualisation - participant estimation - expert feedback" will be repeated 96 times during this PLM.
Residents and medical students will be randomised by the platform to a Control Group and a PLM group. Both groups will participate in two on-line sessions. During the first session, demographic and clinical experience data will be collected. All participants will also perform a pretest to measure their baseline ability to estimate LVEF. Then only the participants randomised to the PLM group will do the PLM. All participants will do a posttest at the end of the first session. Six months later, all participants will return for a second session to perform the delayed test.
At the end of the study, participants of the Control group will be allowed to complete the PLM if they wish to.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Pre, post, delayed test
Participants will not do the PLM, but will perform a pretest, a posttest and a delayed test at 6 months
Pre, post, delayed test
Participants will perform a pretest, a posttest and a delayed test at 6 months.
PLM group (pre, post, delayed test, PLM)
Participants will do a pretest, the PLM, a posttest and a delayed test at 6 months
PLM
Participants will take the PLM on the visual estimation of LVEF. They will also take a pretest, a post-test and a delayed test at 6 months.
Pre, post, delayed test
Participants will perform a pretest, a posttest and a delayed test at 6 months.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
PLM
Participants will take the PLM on the visual estimation of LVEF. They will also take a pretest, a post-test and a delayed test at 6 months.
Pre, post, delayed test
Participants will perform a pretest, a posttest and a delayed test at 6 months.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Residents or medical students with no significant experience in echocardiography
Exclusion Criteria
* Residents or medical students having significant experience with transthoracic or transesophageal echocardiography
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Université de Montréal
OTHER
Centre hospitalier de l'Université de Montréal (CHUM)
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Arnaud Robitaille, MD, FRCPC
Role: PRINCIPAL_INVESTIGATOR
Centre hospitalier de l'Université de Montréal (CHUM)
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Centre Hospitalier de l'Université de Montréal (CHUM)
Montreal, Quebec, Canada
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Champagne P, Girard F, Cyr V, Romanelli G, Ruel M, Todorov A, Robitaille A. The impact of a perceptual learning module on novices' ability to visually estimate left ventricular ejection fraction by transesophageal echocardiography: a randomized controlled study. Can J Anaesth. 2021 Oct;68(10):1527-1535. doi: 10.1007/s12630-021-02066-3. Epub 2021 Jul 28.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
17.119
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.