Noninvasive Measurement of Blood Coagulation

NCT ID: NCT03217799

Last Updated: 2017-07-19

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

140 participants

Study Classification

OBSERVATIONAL

Study Start Date

2017-08-31

Study Completion Date

2019-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The investigators have developed an optical system that measures the coagulation status of patients in vivo in a non-invasive manner. The system is based on a small optical sensor that emits coherent light into the skin and collects the reflected light from the red blood cells in the blood vessels in the skin under the sensor. The sensor is placed on the fingertip, and during a brief period of occlusion of blood flow by a small pneumatic cuff, red cell movement becomes Brownian in nature and is thereby affected by the viscosity of the blood. In patients who have a bleeding tendency, red blood cell movement will be faster, while in patients with a hypercoagulable state the red cell movement will be slower. Treatment with anticoagulant medications is expected to affect the movement of the red blood cells and these changes can be detected by the sensor. The investigators plan to test the device in normal subjects and in subjects taking Coumadin, direct oral anticoagulants, antiplatelet drugs and heparin-based medications. The investigators will determine whether anticoagulants affect the noninvasive measurement and compare the results with standard laboratory tests of coagulation.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Overview: The investigators plan to measure the coagulation status with the new sensor in patients who are attending the Coagulation Clinic in Meir Hospital Center. The investigators will measure their coagulation status with the new sensor during the participants' routine clinic visits. During their visits, The participants' care will not be affected or influenced by the results of the data obtained by the new sensor. The accumulated data will be collected and later correlated with their clinical status and with routine clotting parameters that are measured, depending on the type of anticoagulation the participants receive. Specifically, in those receiving warfarin, INR will be assessed during their visit, while in patients receiving direct oral anticoagulants (DOACs), factor Xa activity will be assessed. Inparticipants receiving heparin, PTT will be assessed.

Patients and control subject: Subjects will be recruited from the Coagulation Clinic. The participants will consist of patients attending the clinic for follow-up of their prescribed anticoagulation treatment. Patients to be studied will include subjects receiving warfarin anticoagulation, NOACs, heparin and anti-platelet therapy (aspirin, clopidrogel or other anti-platelet medications). Normal subjects receiving no anticoagulation will also be studied and will serve as the control group.

Protocol: Experimental subjects will be selected from patients attending the Coagulation Clinic. Patients will be seen in the clinic and receive their usual follow-up care. After obtaining informed consent, the participants' coagulation status will be assessed with the new sensor. Patients on warfarin medications will have a venous blood sample obtained (5 ml) for determination of INR. Patients receiving NOACs will have a venous blood sample obtained (5 ml) for determination of Factor Xa activity. At a later date, the coagulation status of the patients as assessed by the new sensor will be compared to the coagulation status as assessed by the standard laboratory methods.

Normal controls will be recruited from hospital personnel. Normal controls will have their coagulation status assessed by the new sensor only. Since normal control are not receiving anticoagulation therapy, blood samples for measurement of INR or factor Xa activity will not be drawn. Normal controls will receive no financial compensation.

Methodology: The pneumatic cuff is attached to the root of the index finger. The sensor cuff is attached several centimeters distal to the pneumatic cuff. Measurement is taken for a 60-second control period, and then the pneumatic cuff is inflated to above-systolic blood pressure (200 mm Hg) for 180 seconds, and measurement is taken during this period of time. The cuff is then deflated, and another 60-second measurement is taken. Data is collected by the measuring device for later analysis.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Anticoagulants; Increased Anticoagulant Overdosage Coagulation Disorder Blood Clot Blood Coagulation Disorder

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_CONTROL

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Measurement of coagulability of blood

A small pneumatic cuff is attached to the root of the index finger. The sensor cuff is attached several centimeters distal to the pneumatic cuff. Measurement is taken for a 60-second control period, and then the pneumatic cuff is inflated to above-systolic blood pressure (200 mm Hg) for 180 seconds, and measurement is taken during this period of time. The cuff is then deflated, and another 60-second measurement is taken. Data is collected by the measuring device for later analysis.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Subjects receiving anticoagulant therapy, including warfarin, DOACS, heparin, and antiplatelet drugs

Exclusion Criteria

\-
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Meir Medical Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

ORLY AVNERY

Senior Hematologist

Responsibility Role PRINCIPAL_INVESTIGATOR

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Orli Avnery, MD

Role: CONTACT

972-9-7471352

Martin Ellis, MD

Role: CONTACT

972-9-741822

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

0227

Identifier Type: -

Identifier Source: org_study_id