Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
52 participants
OBSERVATIONAL
2017-07-04
2021-07-06
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Imaging method: All patients consented for this study will be imaged on a dedicated scanner for the study, Revolution (GE, Milwaukee, WI). Immediately following the patient's diagnostic chest CT scan, an ultra low dose chest CT scan will be obtained. The routine CT scans of the patients consented for this study will be performed using our routine protocol on the GE Revolution which typically delivers at our institution an average effective dose of 2.9mSv (range 0.95-3.01mSv) while our other Philips routine chest CT scan delivers an average effective dose of 10.5mSv (range 10.29-12.95mSv). With the addition of the ultra low dose technique, which delivers a radiation dose of a range of 0.5-1 mSv (calculated from a pilot study we obtained on pigs), patients are expected to get an total radiation dose for both scans together of about 4 mSv which is less than 10.5mSv (the normal dose for the Phillips CT machine at our institution). Just as a comparison, a meticulous study looking at multiple institutions showed that the average effective dose from a routine chest CT is 7mSv, range 4-18mSv and for a chest CT with pulmonary embolism protocol an average effective dose of 15mSv with a range of 13-40mSv .
Image evaluation: The diagnostic chest CT scan will be sent to the PACS as usual and interpreted immediately, during the same day, as per normal inpatient clinical operations protocol at our institution. The ultra low dose CT scan will be automatically sent to the computational imaging lab processing station, which will denoise the image. After denoising the images will be automatically forwarded to the PACS under the same accession number of the routine chest CT scan. Comparison of the ultra low dose denoised images to the routine chest CT images will be performed by an experienced chest radiologist at a later date, at least one week after date of acquisition to prevent any memorability of the original image. Radiologists' memory of findings has been shown to be poor, even when viewed immediately but slightly worse when time passes \[Evans\]. The radiologist will document the presence of nodules, consolidation, ground glass opacities, emphysema, fibrosis with abnormalities marked on the images in the PACS. Following completion of the table, the routine chest CT scan will be used as the gold standard for the presence of the imaging findings. The documented ultra low dose CT findings will be compared to the images from the routine chest CT scans. Each finding documented will be individually documented as a true finding if also seen on the routine chest CT scan or false finding if not present on the routine chest CT scan. Additional findings only seen on the routine chest CT scan will be documented as missed findings.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Patients scheduled for a chest CT
Inpatients or outpatients scheduled for a chest CT in our medical center
Ultra low dose chest CT
Performing an ultra low dose chest CT (ULDCT) in addition to a clinically indicated chest CT and assessing nodule detection with a recently developed denoising algorithm
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Ultra low dose chest CT
Performing an ultra low dose chest CT (ULDCT) in addition to a clinically indicated chest CT and assessing nodule detection with a recently developed denoising algorithm
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
110 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Sheba Medical Center
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Prof. Edith Marom
Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Edith M Marom, MD
Role: PRINCIPAL_INVESTIGATOR
Sheba Medical Center
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Sheba Medical Center
Ramat Gan, , Israel
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
SHEBA - 16- 3651- EM - CTIL
Identifier Type: -
Identifier Source: org_study_id