Comparison of LigaSure to Conventional Electrocoagulation in Video-assisted Thoracoscopic Surgery Lobectomy

NCT ID: NCT03125798

Last Updated: 2024-09-03

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

216 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-05-03

Study Completion Date

2021-11-04

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Surgical treatment of lung cancer consists of two elements: anatomical lung resection (segmentectomy, lobectomy or pneumonectomy) followed by mediastinal lymph node dissection (MLND). Since over last 15 years the growing rate of resection is performed by minimal invasive approach - video-assisted thoracoscopic surgery (VATS). The study is focused on the clinical and technical aspects of MLND during VATS lobectomy. The extension of lymph nodes resection is strictly specified. The main benefit of MLND for the patient is precise histopathological staging, which allows choosing the best therapeutic option of adjuvant therapy. MLND is related with potential minor and major complications (bleeding, increased volume of chest tube drainage, prolonged chest tube duration and hospital stay, chylothorax, left recurrent laryngeal nerve injury, injury of the bronchus, injury of the esophagus). The majority of complications are caused by thermal injury resulting from the use of heat-generating monopolar electrocautery that is commonly used during lymph nodes dissection. In addition, thermal energy generation in case of monopolar electrocautery may lead to systemic inflammatory response and increased surgical injury. High-energy sealing devices like LigaSure™ allow for dissection, coagulation and cutting with the single instrument. Compared to mechanical ligation techniques (vessel loops, clips) or monopolar electrocautery, LigaSure™ technology has been shown to reduce: intraoperative blood loss (in colorectal, gynecologic and urologic surgery), surgery time (in colorectal, gynecologic and urologic surgery), length of hospital stay (in gynecologic and urologic surgery). Investigators hypothesize that application of LigaSure™ in VATS anatomical resection may lead to diminished complications rate, lower systemic inflammatory response and shorter length of stay compared to monopolar electrocautery.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Summary

Surgical treatment of lung cancer consists of two elements: anatomical lung resection (segmentectomy, lobectomy or pneumonectomy) followed by mediastinal lymph node sampling (MLNS) or mediastinal lymph node dissection (MLND). Since over last 15 years the growing rate of resection is performed by minimal invasive approach - video-assisted thoracoscopic surgery (VATS). This technique is used in at least 60% of patients with lung cancer operated on in the leading centers. The study project is focused on the clinical and technical aspects of MLNS/MLND during VATS lobectomy. Lymphadenectomy has to be performed obligatory in case of lung cancer resection. The extension of lymph nodes resection or sampling is strictly specified and should be the same independently from the surgical approach (thoracotomy or VATS). The main benefit of MLNS/MLND for the patient is precise histopathological staging, which allows choosing the best therapeutic option of adjuvant therapy. It was proved that MLND is superior to MLNS in its accuracy however the improvement of local control of the disease is not proved.

Mediastinal lymphadenectomy is related with potential minor and major complications. The risk of complications is low but in case of their occurrence hospital stay is usually significantly prolonged, quality of life decreases and additional surgery may be needed. In very small group of patients complications may lead to severe disability or death.

The most frequent complications related with MLND are:

1. Bleeding, sometimes requiring redo surgery;
2. Increased volume of chest tube drainage with prolonged chest tube duration and hospital stay;
3. Chylothorax;
4. Left recurrent laryngeal nerve injury;
5. Injury of the bronchus (especially of posterior part of right main bronchus during dissection of subcarinal lymph nodes);
6. Injury of the esophagus (dissection of subcarinal and paraesophageal lymph nodes).

The majority of the above mentioned complications are caused by thermal injury resulting from the use of heat-generating monopolar electrocautery that is commonly used during lymph nodes dissection. Bleeding or chylothorax are usually caused by incomplete blood or lymphatic vessels closure. Esophageal or bronchial wall injury can be caused by thermal injury followed by ischemia, necrosis and finally perforation. The diagnosis is frequently delayed. In addition, thermal energy generation in case of monopolar electrocautery may lead to systemic inflammatory response and increased surgical injury. Extent of surgical injury measured by acute phase proteins levels (c-reactive protein, alpha-1-antitrypsin, alpha-1-acid glycoprotein, haptoglobin) and interleukin levels was proved to be correlated to long-term results in patients with colorectal cancer.

Introduction of new high-energy sealing devices like LigaSure™ to clinical practice allows for dissection, coagulation and cutting with the single instrument. Compared to mechanical ligation techniques (vessel loops, clips) or monopolar electrocautery, LigaSure™ technology has been shown to significantly reduce:

* Operative blood loss in colorectal, gynecologic and urologic surgery
* Perioperative blood transfusions in gynecologic, urologic and general surgery
* Procedure time in colorectal, gynecologic and urologic surgery
* Length of hospital stay in gynecologic and urologic surgery.

There have been no randomized studies comparing the use of traditional electrocautery and LigaSure for lymphadenectomy during VATS resection due to non-small cell lung cancer.

Investigators hypothesize that application of LigaSure™ in VATS anatomical resection may lead to diminished complications rate, lower systemic inflammatory response and shorter length of stay compared to monopolar electrocautery.

Study design

Patients with early stage NSCLC who are routinely operated on by VATS will be randomized into two groups. First group called electro-VATS (Monopolar electrocautery) will be operated on with the use of traditional electrocautery and the second called liga-VATS (LigaSure) with the use of LigaSure. In the first group during the whole procedure (dissection of pulmonary ligament, mediastinal pleura and adhesions, as well as hilar dissection and lymphadenectomy) only traditional monopolar electrocautery will be used. In the liga-VASTS patients only LigaSure will be applied,no monopolar electrocautery will be used. The procedure of VATS lobectomy or segmentectomy will be performed in standardized fashion with separate stapling of hilar vessels and bronchus and lung parenchyma division. The hilar dissection and mediastinal lymphadenectomy will be performed using either monopolar electrocautery or LigaSure according to the randomization. The extent of lymphadenectomy will be the same in both groups and will include stations 2R,4R,7,8R,9R,10R,11R on the right side and stations 5,6,7,8L,9L,10L,11L on the left side. The number of removed lymph nodes will be counted. The extension of lymphadenectomy will be controlled and supervised by main investigator. Deep temperature inside the esophagus at the level approximately 2-3 cm below the carina will be measured during lymphadenectomy in order to assess the differences in the exposure of the surrounding tissues to the thermal energy generated by either LigaSure or electrocautery. The temperature measurement should in some part reflect the potential risk of thermal injury to the esophagus caused by different energy devices.

Investigators plan to enroll 200 patients, 100 patients in each group. Initial assessment will include age, gender, comorbidities (Charlson Comorbidity Index, CCI and Thoracic Revised Cardiac Risk Index, thRCRI scores) and pulmonary function tests. The following factors/parameters will be measured/compared in both groups: 24-hour, 48-hour and total volume of chest tube drainage, chest tube duration and hospital stay, rate of the prolonged air leak, rate of redo surgery due to bleeding, rate of postoperative complications related to the procedure, intraoperative blood loss and time of the surgery, local thermal effect, systemic inflammatory response after surgery.

Statistical analysis

The analyzed data will be presented as means, standard deviations, minimum and maximum values, medians, interquartile ranges (lower quartile, upper quartile) or percentage, as appropriate. Normality of the distribution will be tested with the Shapiro-Wilk's test, and the equality of variances will be checked with the Levene's test. For comparison of groups, unpaired t test or one-way ANOVA (for data which follow normal distribution and homogeneity of variances) or Welch test will be applied. In case data will not normally distributed nonparametric tests will be used - Mann-Whitney U test or the Kruskal-Wallis test with the Dunn's post-hoc test. Categorical data will be analyzed with the χ2 test or the Fisher-Freeman-Halton test. The relationship between variables will be analyzed with the Pearson's linear correlation coefficient or the Spearman's rank correlation coefficient or (and) by multivariate linear regression. All the results will be considered significant at p\<0.05. Statistical analyses will be performed with statistical packages: STATISTICA 10.0 PL (StatSoft. Inc.) or StatXact 9.0 (CytelStudio) software.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Lung Cancer Complication of Surgical Procedure

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

LigaSure

In this arm, LigaSure™ will be used for mediastinal lymph nodes dissection, according to standard surgical technique.

Group Type EXPERIMENTAL

LigaSure™

Intervention Type DEVICE

LigaSure™ is supposed to provide improved closure of lymphatic and blood vessels during mediastinal lymph nodes dissection.

Monopolar electrocautery

In this arm, conventional monopolar electrocautery will be used for mediastinal lymph nodes dissection, according to standard surgical technique.

Group Type ACTIVE_COMPARATOR

Monopolar electrocautery

Intervention Type DEVICE

Monopolar electrocautery will be used according to the standard technique for the mediastinal lymph node dissection.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

LigaSure™

LigaSure™ is supposed to provide improved closure of lymphatic and blood vessels during mediastinal lymph nodes dissection.

Intervention Type DEVICE

Monopolar electrocautery

Monopolar electrocautery will be used according to the standard technique for the mediastinal lymph node dissection.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Surgery performed by Video-Assisted Thoracic Surgery technique (VATS).
* Mediastinal Lymph Node Dissection performed due to the European Society of Thoracic Surgeons
* Patients must be informed and must sign and give written informed consent.

Exclusion Criteria

* Preoperative radiotherapy.
* Preoperative chemotherapy.
* Mediastinoscopy or other surgical procedures of mediastinum prior to the present surgery.
* Chest surgery on the side to be operated.
* Conversion from VATS to thoracotomy
Minimum Eligible Age

18 Years

Maximum Eligible Age

85 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Medtronic

INDUSTRY

Sponsor Role collaborator

Wielkopolskie Centrum Pulmonologii i Torakochirurgii

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Cezary Piwkowski, Prof

Role: PRINCIPAL_INVESTIGATOR

Wielkopolskie Centrum Pulmonologii i Torakochirurgii

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Wielkopolskie Centrum Pulmonologii i Torakochirurgii

Poznan, Wielkopolska, Poland

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Poland

References

Explore related publications, articles, or registry entries linked to this study.

Lesser TG, Wolfram F, Boltze C. Sealing of pulmonary arteries with LigaSure: in vivo and ex vivo examinations. J Thorac Cardiovasc Surg. 2013 Jun;145(6):1525-8. doi: 10.1016/j.jtcvs.2012.11.009. Epub 2012 Dec 8.

Reference Type BACKGROUND
PMID: 23228409 (View on PubMed)

Piccinni G, Pasculli A, D'Ambrosio E, Gurrado A, Lissidini G, Testini M. Retrospective comparison of Traditional vs. LigaSure impact dissection during pancreatoduodenectomy: how to save money by using an expensive device. Surg Technol Int. 2013 Sep;23:88-93.

Reference Type BACKGROUND
PMID: 24081851 (View on PubMed)

Lee WJ, Chen TC, Lai IR, Wang W, Huang MT. Randomized clinical trial of Ligasure versus conventional surgery for extended gastric cancer resection. Br J Surg. 2003 Dec;90(12):1493-6. doi: 10.1002/bjs.4362.

Reference Type BACKGROUND
PMID: 14648726 (View on PubMed)

Bertolaccini L, Viti A, Cavallo A, Terzi A. Results of Li-Tho trial: a prospective randomized study on effectiveness of LigaSure(R) in lung resections. Eur J Cardiothorac Surg. 2014 Apr;45(4):693-8; discussion 698. doi: 10.1093/ejcts/ezt445. Epub 2013 Sep 12.

Reference Type BACKGROUND
PMID: 24031044 (View on PubMed)

Kuroda H, Dejima H, Mizumo T, Sakakura N, Sakao Y. A new LigaSure technique for the formation of segmental plane by intravenous indocyanine green fluorescence during thoracoscopic anatomical segmentectomy. J Thorac Dis. 2016 Jun;8(6):1210-6. doi: 10.21037/jtd.2016.04.61.

Reference Type BACKGROUND
PMID: 27293839 (View on PubMed)

Gabryel P, Roszak M, Skrzypczak P, Gabryel A, Zielinska D, Sielewicz M, Campisi A, Kasprzyk M, Piwkowski C. Identification of Factors Related to the Quality of Lymphadenectomy for Lung Cancer: Secondary Analysis of Prospective Randomized Trial Data. J Clin Med. 2023 May 31;12(11):3780. doi: 10.3390/jcm12113780.

Reference Type DERIVED
PMID: 37297976 (View on PubMed)

Gabryel P, Kasprzyk M, Roszak M, Campisi A, Smolinski S, Zielinski P, Piwkowski C. Comparison of the LigaSure bipolar vessel sealer to monopolar electrocoagulation for thoracoscopic lobectomy and lymphadenectomy: a prospective randomized controlled trial. Surg Endosc. 2023 Jun;37(6):4449-4457. doi: 10.1007/s00464-023-09892-0. Epub 2023 Feb 15.

Reference Type DERIVED
PMID: 36792782 (View on PubMed)

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol

View Document

Document Type: Statistical Analysis Plan

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

TH-17-ML-1

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

LigaSure vs Bipolar Diathermy in Thyroidectomy
NCT07274891 NOT_YET_RECRUITING NA