Trial Outcomes & Findings for Accuracy of Methemoglobin Measurement for Rainbow Universal Pulse Oximeter Sensor (NCT NCT03125005)

NCT ID: NCT03125005

Last Updated: 2017-07-27

Results Overview

Accuracy willl be determined by comparing the noninvasive blood methemoglobin measurement (expressed as a percentage of total hemoglobin) of the pulse oximeter to that obtained from a blood sample and calculating the arithmetic root mean square(Arms) error value.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

51 participants

Primary outcome timeframe

5 hours

Results posted on

2017-07-27

Participant Flow

Participant milestones

Participant milestones
Measure
Rainbow Universal Pulse Oximeter Sensor
All subjects will be enrolled in the test group and will receive Rainbow Universal Pulse Oximeter Sensor. Rainbow Universal Pulse Oximeter Sensor
Overall Study
STARTED
51
Overall Study
COMPLETED
51
Overall Study
NOT COMPLETED
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Accuracy of Methemoglobin Measurement for Rainbow Universal Pulse Oximeter Sensor

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Rainbow Universal Pulse Oximeter Sensor
n=51 Participants
All subjects will be enrolled in the test group and will receive Rainbow Universal Pulse Oximeter Sensor. Rainbow Universal Pulse Oximeter Sensor
Age, Categorical
<=18 years
0 Participants
n=5 Participants
Age, Categorical
Between 18 and 65 years
51 Participants
n=5 Participants
Age, Categorical
>=65 years
0 Participants
n=5 Participants
Sex: Female, Male
Female
29 Participants
n=5 Participants
Sex: Female, Male
Male
22 Participants
n=5 Participants
Region of Enrollment
United States
51 participants
n=5 Participants

PRIMARY outcome

Timeframe: 5 hours

Accuracy willl be determined by comparing the noninvasive blood methemoglobin measurement (expressed as a percentage of total hemoglobin) of the pulse oximeter to that obtained from a blood sample and calculating the arithmetic root mean square(Arms) error value.

Outcome measures

Outcome measures
Measure
Rainbow Universal Pulse Oximeter Sensor
n=51 Participants
All subjects will be enrolled in the test group and will receive Rainbow Universal Pulse Oximeter Sensor. Rainbow Universal Pulse Oximeter Sensor
Accuracy of Sensor by Arms Calculation
0.63 Percentage of total hemoglobin

Adverse Events

Rainbow Universal Pulse Oximeter Sensor

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Vikram Ramakanth

Masimo

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place

Restriction type: LTE60