Efficacy of Dotarem® (Gd-DOTA) Versus Gadovist® (Gd-DO3A-butrol) for Late Gadolinium Enhancement Cardiac Magnetic Resonance

NCT ID: NCT03057561

Last Updated: 2019-01-22

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

120 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-10-01

Study Completion Date

2021-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This project is designed to demonstrate equivalence of Dotarem enhanced LGE-CMR (late gadolinium enhancement cardiac MRI) with Gadoviost enhanced LGE-CMR from the standpoint of visual image quality, quantitative image quality, and association with clinical outcomes.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Gadolinium-containing contrast agents (GdCAs) are intravenous agents used for contrast enhancement with magnetic resonance imaging (MRI) and with magnetic resonance angiography (MRA). The GdCAs (gadodiamide, gadopentetic acid, gadobenic acid, gadoxetic acid, gadoteridol, gadobutrol and gadoteric acid) have been in use for few decades for different types of MR scan varying from product to product, including liver, brain, and whole body scan.

Recently, there has been a great interest in employing contrast-related techniques to assess for fibrosis in the myocardium of the heart. As opposed to nuclear methods, viability assessment by MRI is a nonstress examination that provides high-resolution detail, including functional assessment of the left ventricle in approximately 30 minutes. Assessment of myocardial viability is performed using 5- to 20-minute delayed, gadolinium-enhanced MRI. On delayed MRI, there is a relatively decreased washout of the gadolinium contrast agent in areas of myocardium that have been replaced by fibrosis or scar. In normal viable myocardium, the gadolinium contrast agent washes out more rapidly than it does from the fibrosis or scar. Since the difference between normal and abnormal myocardium is based on washout kinetics, images that are delayed by 5 to 20 minutes after contrast injection will optimally depict the fibrosis or scar.

The differences in gadolinium enhancement on MRI of viable myocardium and fibrosis or scar have been known for many years. Recently, however, MRI pulse sequences have been developed that greatly improve the conspicuity of the enhanced areas of myocardium that have been replaced by fibrosis or scar. The pulse sequence used is an inversion-recovery prepared gradient-echo sequence. In this method, an inversion pulse is used to null the signal from normal myocardium. Myocardium that is replaced by fibrosis or scar retains gadolinium and shows very high signal intensity compared with the suppressed, darker myocardium.

Gadovist has been the standard gadolinium contrasts used in the U.S. in CMR imaging for the past few years. On the other hand, Dotarem, a widely used contrast agent in Europe, has been introduced to be used in the U.S. market.The sensitivity of Dotarem to that of Magnevist in determining the location and extent of scar in patients scanned with CMR will be Gadovist in this study.

The CMR laboratory at the Houston Methodist DeBakey Heart \& Vascular Center is one of the largest dedicated CMR laboratories in the U.S. performing 3,000 clinical CMR procedures per year. The laboratory has been in existence since 2008 and is currently equipped with 2 dedicated MRI scanners: 1.5T Siemens Avanto and 3.0T Siemens Verio. Through a research agreement with Siemens Medical Solutions, the laboratory has access to numerous works-in progress sequences as they are developed. The laboratory is equipped with an MRI compatible patient monitoring system, infusion pump, and power injector and is staffed by a team of 5 dedicated CMR technologists, 2 clinical nurses, 1 CMR fellow, an MRI scientist, and 2 attending cardiologists.

One hundred twenty patients with known or suspected cardiovascular disease will be recruited for this study. Patients will be randomized (in a 1:1 fashion) to receive either Dotarem or Gadovist for LGE-CMR such that there will be 60 patients in the Dotarem cohort and 60 patients in the Gadovist cohort.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coronary Artery Disease Cardiomyopathy

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

SINGLE_GROUP

Evaluating the efficacy of Dotarem enhanced MRI compared to Gadovist enhanced MRI in identifying myocardial fibrosis. Patients will be randomized (in a 1:1 fashion) to receive either Dotarem or Gadovist for LGE-CMR such that there will be 60 patients in the Dotarem cohort and 60 patients in the Gadovist cohort
Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

SINGLE

Outcome Assessors
Blinded reader of scans will not know whether subject received Dotarem or Gadovist.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

3.0 Tesla Cardiac MRI using Dotarem contrast agent

60 randomly selected participants with suspected or known cardiovascular disease will have a 3.0 Tesla Cardiac MRI with contrast agent, Dotarem

Group Type EXPERIMENTAL

Cardiac MRI taken using contrast agent, Dotarem® (Gd-DOTA)

Intervention Type DRUG

Gadolinium based contrast agent used in cardiac MRI scanning using 3.0 Tesla MRI

Cardiac MRI with contrast agent, Gadovist

Intervention Type DRUG

Brand of Gd-DO3A-butrol; contrast agent used in cardiac MRI scanning using 3.0 Tesla MRI

3.0 Tesla Cardiac MRI using a Gadovist contrast agent

60 randomly selected participants with suspected or known cardiovascular disease will have a 3.0 Tesla Cardiac MRI with contrast agent, Gadovist

Group Type EXPERIMENTAL

Cardiac MRI taken using contrast agent, Dotarem® (Gd-DOTA)

Intervention Type DRUG

Gadolinium based contrast agent used in cardiac MRI scanning using 3.0 Tesla MRI

Cardiac MRI with contrast agent, Gadovist

Intervention Type DRUG

Brand of Gd-DO3A-butrol; contrast agent used in cardiac MRI scanning using 3.0 Tesla MRI

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Cardiac MRI taken using contrast agent, Dotarem® (Gd-DOTA)

Gadolinium based contrast agent used in cardiac MRI scanning using 3.0 Tesla MRI

Intervention Type DRUG

Cardiac MRI with contrast agent, Gadovist

Brand of Gd-DO3A-butrol; contrast agent used in cardiac MRI scanning using 3.0 Tesla MRI

Intervention Type DRUG

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Cardiac MRI with contrast CMR with tracer or contrast agent Dotarem (Gd-DOTA) contrast agent Cardiac MRI with contrast CMR with tracer or contrast agent Gadovist® (Gd-DO3A-butrol) contast agent

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients undergoing clinically referred CMR.

Exclusion Criteria

1. Patients who are unable to give informed consent.
2. Individuals with severe claustrophobia.
3. Individuals unable to lie flat for 90 minutes (the anticipated amount of time to complete the MRI procedure).
4. Individuals who are pregnant.
5. Patients with implants or pacemakers.
6. Patients that have hypersensitivity to components of gadolinium.
7. Patients with renal failure.
8. Patients who had any trauma or surgery which may have left ferromagnetic material in the body.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Guerbet

INDUSTRY

Sponsor Role collaborator

Dipan Shah

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Dipan Shah

Director, Cardiac Magnetic Resonance Imaging

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Dipan Shah, MD

Role: PRINCIPAL_INVESTIGATOR

The Methodist Hospital Research Institute

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Pro00012234

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Eovist vs. Dotarem Healthy Volunteer MRI
NCT02431598 COMPLETED PHASE4
Myocardial Perfusion MRI
NCT01490294 COMPLETED PHASE2