The Effectiveness of Ologen® Collagen Matrix in Preventing Intraocular Pressure (IOP) Spikes After Ahmed Glaucoma Valve Surgery (AGV-FP7)

NCT ID: NCT02990143

Last Updated: 2021-03-17

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

TERMINATED

Clinical Phase

PHASE2

Total Enrollment

30 participants

Study Classification

INTERVENTIONAL

Study Start Date

2014-01-15

Study Completion Date

2017-12-15

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to investigate whether placing Ologen over the posterior plate of the Ahmed glaucoma drainage device during initial implantation will allow the formation of a thinner capsule, and decrease the incidence and/or the extent of IOP elevation during the postoperative period.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Uncontrolled glaucoma may require surgical intervention. Glaucoma drainage implants such as AGV-FP7 are in wide use upon glaucoma and comprehensive surgeons. The success of aqueous shunt surgery depends on the formation and maintenance of a thin permeable capsule around the posterior plate of the aqueous shunt. Encapsulated bleb formation, where the capsule is thick and elevated, is a common cause of drainage failure in the early post-operative period. This finding is usually accompanied by elevated intraocular pressure (IOP), which requires additional intervention, often surgical and therefore reduces the success rate of the initial surgery.

Recently, a biodegradable porous collagen-glycosaminoglycan copolymer matrix implant (Ologen), has become available for glaucoma surgery. This device is constructed so as to minimize random growth of fibroblasts and instead to allow them to grow through the pores in the matrix. Ologen® CM,a biodegradable scaffold matrix, induces a regenerative non-scarring wound healing process without using anti-fibrotic agents.

This study is to investigate whether placing Ologen over the posterior plate of the Ahmed glaucoma drainage device during initial implantation will allow the formation of a thinner capsule, and decrease the incidence and/or the extent of IOP elevation during the postoperative period.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Glaucoma

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Participants

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Glaucoma Drainage implant no Ologen

The first group will use the routine technique for glaucoma drainage implant without placement of Ologen.

Group Type NO_INTERVENTION

No interventions assigned to this group

Glaucoma Drainage implant with Ologen

the second group will undergo the same procedure but will have the Ologen placed and secured over the plate of the AGV-FP7, under the conjunctiva, during the surgery.

Group Type ACTIVE_COMPARATOR

Ologen

Intervention Type PROCEDURE

Ologen® CM,a biodegradable scaffold matrix, induces a regenerative non-scarring wound healing process without using anti-fibrotic agents.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Ologen

Ologen® CM,a biodegradable scaffold matrix, induces a regenerative non-scarring wound healing process without using anti-fibrotic agents.

Intervention Type PROCEDURE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age ≥18 years.
* Uncontrolled treated glaucoma requiring AGV-FP7 surgery.
* Subject must be able and willing to cooperate with investigation plan.
* Subject must be able and willing to complete postoperative follow-up requirements
* Subject must be willing to sign informed consent form

Exclusion Criteria

* Known allergic reaction to porcine collagen
* History of uveitis
* Corneal opacity or irregularity, preventing visualization of patency of tip of tube or accurate applanation
* History of scleral buckle
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

The New York Eye & Ear Infirmary

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Noga Harizman, MD

Role: PRINCIPAL_INVESTIGATOR

NY Eye Ear

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

New York Eye and Ear Infirmary

New York, New York, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

13.33

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Trabeculectomy With Ologen
NCT01753492 TERMINATED NA