Optiflow Preoxygenation

NCT ID: NCT02981511

Last Updated: 2016-12-05

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

20 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-10-31

Study Completion Date

2017-01-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Optiflow can be used to prolong the apnoea period under anaesthesia without falls in blood oxygen saturation. This study is designed to assess whether the Optiflow system can efficiently replace conventional anaesthetic mask and circuit preoxygenation so that it could be used in emergency anaesthesia. If so, it would be then be in place in the case of difficult or failed intubation to maintain oxygenation ie: it could preoxygenate and then maintain oxygenation seamlessly.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The Optiflow device is used to deliver high flow humidified oxygen/air via nasal cannulae to patients who have respiratory problems. More recently it has been used in patients having surgery on their larynx who are intentionally paralysed under anaesthesia where the surgeon does not want any tubes in the airway. This makes access for surgery easier/possible. Perhaps surprisingly, these patients can be left apnoeic for 30 minutes without falls in blood oxygen levels. The lungs are oxygenated despite there being no in and out breathing/ventilation.

We propose that applying Optiflow at the start of an emergency anaesthetic may be beneficial when an anaesthetist finds that tracheal intubation is impossible - a "failed intubation" scenario. Optiflow might maintain oxygenation during further attempts at intubation or until more skilled anaesthetists arrive.

Another alternative technique presently in common use is for the patient to breathe 100% oxygen via a facemask and conventional anaesthetic circuit for 3 minutes before anaesthesia starts (preoxygenation). This fills the functional residual capacity of the lungs to about 90% oxygen giving an oxygen reserve when the breathing stops until the anaesthetist breathes for them after intubating the trachea. This can result in the maintenance of normal blood oxygen saturation for several minutes longer than would be the case if the lungs had only been exposed to air before anaesthesia.

The research question that we ask is whether we can just use Optiflow instead of the conventional mask/circuit to preoxygenate patients to a similar extent and as quickly as using a facemask so that, in emergency surgery, Optiflow could be used to preoxygenate and then already be in place in case there is a failed intubation. This would enable Optiflow to be used for both purposes seamlessly without the need to switch between the two methods of oxygenation.

Research to date has not yet identified how long Optiflow needs to be in place before anaesthesia for it to be able to produce adequate preoxygenation of the lungs before the patient stops breathing. The 3 minute timing for preoxygenation is important in emergency cases e.g. when there is an emergency caesarean section to be done and every minute before the baby is delivered matters. If it were not possible to preoxygenate a patient's lungs within 3 minutes using Optiflow we would suggest that it is inappropriate to replace conventional mask pre-oxygenation and that its value in emergency anaesthesia might be reduced (although it may still have potential for less urgent anaesthesia when it could be applied for a longer duration before anaesthesia).

This will be a pilot study with 20 healthy volunteer students as subjects who will undergo an up / down sequential analysis of Optiflow pre-oxygenation. They will be recruited from posters inviting them to consider enrolling in the project. They will receive a subject information sheet and will provide written informed consent.

On the study day an individual subject will lie supine on a trolley and the Optiflow device will be fitted ready to administer humidified 100% oxygen at 45 l/min via the device's nasal cannulae. The subject will be asked to breathe normally with a closed mouth and the device will be switched on.

The initial test period will be for 3 minutes and at the end of that time the device will be turned off with the subject holding their breath in inspiration and the subject will then exhale and then breathe normally via a mouthpiece which has a side sampling port connected to a standard gas monitor (as used during anaesthesia) which will measure and display the expired oxygen percentage. This is known to equate very well to the alveolar oxygen fraction in healthy subjects and the target value will be 85%.

After the initial test the subject will be asked to walk around breathing room air for at least 15 minutes to return their lung gases to pre test normality.

The process will then be repeated as before but for a different duration:

If the target of 85% had not been reached within 3 minutes the 2nd test would be for 5 minutes.

If the 85% target had been reached the 2nd test would be reduced to 2.5 minutes.

The test runs would continue in the same up/down fashion until the minimum time required to reach 85% had been identified (to the nearest 30 seconds) or the subject had done test runs up to 10 minutes long without reaching the target.

If the subject wished to split the test runs over more than one session that would be accommodated. They would also be free to leave the study at any time if they so desired.

Subsequent subjects will have an initial test duration adjusted to the average of the previous subjects so that they may not be required to undergo as many tests (this presumes that there is not too much variation within the population) and will be less inconvenienced.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Preoxygenation, Apnoea, Anaesthesia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

BASIC_SCIENCE

Blinding Strategy

NONE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

optiflow

Optiflow device used for preoxygenation

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* healthy (ASA1or 2)

Exclusion Criteria

* respiratory disease
Minimum Eligible Age

20 Years

Maximum Eligible Age

35 Years

Eligible Sex

FEMALE

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University Hospital Southampton NHS Foundation Trust

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University Hospital Southampton

Southampton, Hants, United Kingdom

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

United Kingdom

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

patrick butler, MBChB

Role: CONTACT

Phone: 02380777222

Email: [email protected]

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Patrick Butler, MBChB

Role: primary

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

RHMCRI0333

Identifier Type: -

Identifier Source: org_study_id