Safety and Efficacy of Implantation of Two Multifocal Intraocular Lenses in the Treatment of Senile Cataract
NCT ID: NCT02966496
Last Updated: 2016-11-17
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
40 participants
INTERVENTIONAL
2016-01-31
2018-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
As first reported in 1987 by Keatea et al., multifocal IOLs were introduced to provide improved visual acuity, thus eliminating the need to wear glasses and improving the patient's quality of life. Increasing evidence-based medicine evidences have shown that multifocal IOLs are more adept to improving near vision than single-focus IOLs. To date, various types of multifocal IOLs have been developed and according to different design principles, clinically used multifocal IOLs have been divided into refraction type, diffraction type and refraction/diffraction type. Introduced in 2002, the Tecnis Z9001 diffractive multifocal aspherical IOL (Abbott Medical Optics, CA, USA) is clinically proven to give patients improved contrast vision and visual quality when compared with the common IOL, although deficiencies include postoperative glare and reduced contrast sensitivity. Emerging designs for multifocal IOLs aim to provide improvements in postoperative visual quality. The Acri.LISA 366D multifocal aspheric IOL is a relatively novel refractive/diffractive multifocal IOL that is different from traditional IOLs. Its unique optical design improves the patient's full vision and reduces the incidence of light scattering, glare and halo, which is expected to deliver better clinical outcomes. However, its long-term clinical performance and the potential incidence of complications still need further evaluation.
It is worth noting that as age increases, the increase in presbyopia, aberrations and lens scattering reduces the compensation for corneal aberrations, thereby resulting in a decrease in visual acuity and contrast sensitivity. Given this, ideal IOLs should have good biocompatibility and good resolution with no spherical aberration.
Data collection, management, analysis, and open access Data collection Clinical data will be collected and managed using an electronic data capture system. All data relevant to the trial will be recorded in electronic case report forms that will be provided by the sponsor personnel. The case report will be completed after the interview.
Data management After completion of follow-up and data confirmation, only the project manager will lock the database. The locked data will be unable to be altered and will be preserved for future reference by the Affiliated Hospital of Qinghai University in China.
Data analysis All data will be statistically analyzed by professional statisticians.
Open data Published data will be released at http://www.medresman.org.
Statistical analysis All data will be statistically analyzed by statisticians using SPSS v19.0 software. Normally distributed measurement data will be expressed as mean ± standard deviation, while non-normally distributed data will be expressed as quartiles and medians. Categorical variables will be expressed as counts and percentages. Two-sample t-test or Mann-Whitney U-test will be used for intergroup comparison of visual acuity and diopter. The chi-squared test or Fisher's exact test will be used for intergroup comparison of incidence of histocompatibility reactions between the implant and host tissues and the percentage of complications. A value of P \< O.05 will be considered statistically significant.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
the test group
The patients aged 50-80 years will be randomly assigned to implantation of Acri.LISA366D multifocal aspheric IOLs in the test group.
Acri.LISA366D multifocal aspheric IOLs
The implantation of Acri.LISA366D multifocal aspheric IOLs are used in the test group.
the control group
The patients aged 50-80 years will be randomly assigned to implantation of TecnisZ9001 multifocal aspheric IOLs in the control group.
TecnisZ9001 multifocal aspheric IOLs
The implantation of TecnisZ9001 multifocal aspheric IOLs are used in the test group.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Acri.LISA366D multifocal aspheric IOLs
The implantation of Acri.LISA366D multifocal aspheric IOLs are used in the test group.
TecnisZ9001 multifocal aspheric IOLs
The implantation of TecnisZ9001 multifocal aspheric IOLs are used in the test group.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Corneal astigmatism \< 1.0 D
* Lens hardness, II-III
* Initial surgery on the eye
* Age 50-80 years
* Healthy and able to tolerate anesthesia and surgery
Exclusion Criteria
* Fundus disease, corneal edema, corneal opacity, endophthalmitis, and/or iris adhesion.
* Prior experience of eye surgery
* Failure to make regular referrals
* Autoimmune disease, mental illness or other serious systemic disease
* Inability to cooperate with the researchers
* Inability to tolerate surgery
* Sensitivity, anxiety or the pursuit of perfection
* Inability to give informed consent
50 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Qinghai University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Ping Yu, Master
Role: PRINCIPAL_INVESTIGATOR
Affiliated Hospital of Qinghai University
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
QinghaiUH_005
Identifier Type: -
Identifier Source: org_study_id