MERIT Study - Mistral Percutaneous Mitral Valve Repair FIM Study

NCT ID: NCT02948231

Last Updated: 2022-04-07

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

4 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-06-25

Study Completion Date

2022-02-28

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The Mistral is an investigational device intended for percutaneous trans-catheter repair in high risk for surgery individuals suffering from functional Mitral Regurgitation.

The device system is to be used only in accordance with the approved Investigational Plan on subjects who have signed an informed consent form. Device use is limited to the approved study investigators.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The study is designed to clinically demonstrate device acute safety (Primary Endpoint) along with longer FU device safety and effectiveness evaluation (Secondary Endpoint).

The main objectives of the study are :

* Evaluate the Acute safety of the implanted Mistral device post procedure and at 30 day follow up period.
* Evaluate the long term Safety of the device (3 and 6 months follow up).
* Demonstrate effectiveness of the Mistral device in improving MR.

Primary endpoints:

• Safety: Acute safety. Rate of device related SAE including device related mortality, stroke, MI, cardiac tamponade, surgery for failed percutaneous repair and non-elective cardiovascular surgery to treat an adverse event. At discharge and 30 days.

Secondary endpoints:

* • Safety: Safety at 3 and 6 months. Rate of SAEs and device related SAEs at 3, 6 and 12months.
* Effectiveness: MR reduction post-procedure, at discharge and 30 days, 3 and 6 and 12 months. Improved NYHA class and 6MWT distance at 30 days, 3 and 6 and 12 months.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Mitral Valve Regurgitation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Mistral

Group Type EXPERIMENTAL

Mistral implantation

Intervention Type DEVICE

Mistral Implant is implanted in the Mitral valve

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Mistral implantation

Mistral Implant is implanted in the Mitral valve

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Subject is willing and able to comply with all required follow-up evaluations
* Genders eligible for the study: Both genders
* Subject has functional MR of grade 3+ or more
* Subject has left ventricular ejection fraction (LVEF) \>20 % and \< 40%.
* No contraindications to trans-septal puncture
* Subject is of functional class 3 or more (NYHA)
* The subject is high risk to undergo MV surgery.
* Subject is excluded from other standard of care procedures as determined by center heart team.
* Patients with femoral veins enabling catheterization with 12Fr catheters
* Life expectancy ≥ 1 year

Exclusion Criteria

* Mitral Stenosis ≥ moderate
* Aortic Stenosis/Insufficiency \> moderate
* Subvalvular calcification or calcification of the chordae.
* Subject has a prosthesis valve in the mitral position
* Transcatheter aortic valve replacement (TAVR) within 30 days prior to subject registration
* Subject has a history of a cerebral vascular accident (CVA) or transient ischemic attack (TIA) within the past 3 months.
* Subject has a history of a myocardial infarction (MI) in the past 3 months
* Subject refuses blood transfusion or surgical valve replacement.
* Subject has had a percutaneous interventional or other invasive cardiac or peripheral procedure ≤ 7 days of the index procedure
* Subject has a history of, or has active endocarditis
* Subject has echocardiographic evidence of intra-cardiac mass, thrombus, vegetation or soft-mobile deposits
* Subject is in acute pulmonary edema.
* Subject has hemodynamic instability requiring inotropic or mechanical support.
* Subject has a known hypersensitivity or contraindication to anticoagulant or antiplatelet medication
* Subject has renal insufficiency as evidenced by a serum Creatinine \> 3.0mg/dL.
* Subject has ongoing infection or sepsis
* Subject has blood dyscrasias (leukopenia, acute anemia, thrombocytopenia, history of bleeding diathesis, or coagulopathy)
* Subject has an active peptic ulcer or has had gastrointestinal (GI) bleeding within the past 3 months prior to the index procedure
* Subject requires emergency surgery for any reason
* Subject has a known allergy to Nitinol alloys, 316L\\304 stainless steel.
* Pregnant or lactating women.
* Patients being dependent upon the sponsor or upon the investigator or upon the investigational site.
* Subject has a known contrast media allergy
* Presence of high degree atrio-ventricular block (2nd or 3rd degree A-V block), or the presence of tri-fascicular block
* According to investigator on site the patient is suffering from a severe end stage disease (e.g. malignancy, severe pulmonary disease, liver disease, renal failure) and has a life expectancy of less than 1 year.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Mitralix

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

ZNA Middelheim

Antwerp, , Belgium

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Belgium

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CL-133

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

MitraClip REPAIR MR Study
NCT04198870 ACTIVE_NOT_RECRUITING NA
MitraClip® Registry
NCT02033811 RECRUITING
Belgian Mitraclip Registry
NCT02506387 COMPLETED
Capstan Medical TMVR Study: FIH
NCT06600191 RECRUITING NA