Insertion Angle and Needle Visualization During Ultrasound Guided Internal Jugular Vein Cannulation

NCT ID: NCT02941094

Last Updated: 2016-11-22

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

150 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-10-31

Study Completion Date

2017-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Ultrasound guidance has been established as an effective and safe method during insertion of internal jugular vein catheter.. Needle visualization during advancement toward the vein has a great impact on both safety and success of the procedure. Clinicians have adopted variable techniques to increase needle visualization including changing needle- probe relation (in-plane vs. out-of-plane), or using specific ultrasound needles The angle between the inserting needle and the probe lying on patient skin affects both the distance to the vein and the length of the needle part travelling through the us beam

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Internal Jugular Vein Cannulation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

PREVENTION

Blinding Strategy

SINGLE

Participants

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

angle 30 group

During central line insertion, After choosing the proper position, the skin was infiltrated with %1 lidocaine. The vein will be localized using linear ultrasound probe (PLT-805AT, 8 MHz, Toshiba Tokyo, Japan) attached to ultrasound machine (Xario, Toshiba Tokyo Japan). The needle will be advanced guided by the ultrasound probe with needle skin angle 30-40 degree.

Group Type ACTIVE_COMPARATOR

needle PLT-805AT

Intervention Type DEVICE

comparing success rate and complications using different needle to US probe angles.

Ultrasound

Intervention Type DEVICE

Xario, Toshiba Tokyo Japan

angle 50 group

During central line insertion,After choosing the proper position, the skin was infiltrated with %1 lidocaine. The vein will be localized using linear ultrasound probe (PLT-805AT, 8 MHz, Toshiba Tokyo, Japan) attached to ultrasound machine (Xario, Toshiba Tokyo Japan). The needle will be advanced guided by the ultrasound probe with needle skin angle 50-60 degree

Group Type ACTIVE_COMPARATOR

needle PLT-805AT

Intervention Type DEVICE

comparing success rate and complications using different needle to US probe angles.

Ultrasound

Intervention Type DEVICE

Xario, Toshiba Tokyo Japan

angle 70 group

During central line insertion,After choosing the proper position, the skin was infiltrated with %1 lidocaine. The vein will be localized using linear ultrasound probe (PLT-805AT, 8 MHz, Toshiba Tokyo, Japan) attached to ultrasound machine (Xario, Toshiba Tokyo Japan). The needle will be advanced guided by the ultrasound probe with needle skin angle 60-80 degree

Group Type ACTIVE_COMPARATOR

needle PLT-805AT

Intervention Type DEVICE

comparing success rate and complications using different needle to US probe angles.

Ultrasound

Intervention Type DEVICE

Xario, Toshiba Tokyo Japan

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

needle PLT-805AT

comparing success rate and complications using different needle to US probe angles.

Intervention Type DEVICE

Ultrasound

Xario, Toshiba Tokyo Japan

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

PLT-805AT, 8 MHz, Toshiba Tokyo, Japan

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* all patients requiring central line insertion

Exclusion Criteria

* refusal
* coagulopathy
* neck surgeries
Minimum Eligible Age

18 Years

Maximum Eligible Age

65 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Mansoura University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

AlRefaey Kandeel

Dr

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Mansoura university

Al Mansurah, Dkahleya, Egypt

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Egypt

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Alreafey Kandeel, MD

Role: primary

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

refa-US-angle

Identifier Type: -

Identifier Source: org_study_id