Trial Outcomes & Findings for Assessment of Infection Control, Practice Efficiency, and Health Economics of Sheathed Versus Standard Cystoscopy (NCT NCT02922868)
NCT ID: NCT02922868
Last Updated: 2018-09-12
Results Overview
The primary endpoint will be the change in bacteriuria pre- and post-procedure between EndoSheath CST-5000 cystoscope and standard (non-sheathed) Olympus Visera Elite OTV-S190 cystoscope during the course of routine clinical use in a urology clinic. The pre-procedure measurement of bacteriuria will occur on the day of the procedure. The post-procedure measurement of bacteriuria will occur approximately two weeks (10-14 days) post-procedure. This will be assessed by urine culture exams.
COMPLETED
NA
60 participants
10-14 Days Post Procedure
2018-09-12
Participant Flow
Participant milestones
| Measure |
EndoSheath CST-5000 Scope
Cogentix Medical CST-5000 Flexible Video Cystoscope with Slide-On® EndoSheath® Technology. EndoSheath CST-5000 Scope.
EndoSheath CST-5000 Scope: Cystoscopic procedures will be performed using the EndoSheath CST-5000 Scope.
|
Olympus Visera Elite OTV-S190 Scope
Olympus HD Flexible Cysto-Nephro Videoscope (CYF-VH) with Olympus Visera Elite Platform, including OTV-S190 Video Processor CLV-S190 Xenon Light Source. Olympus Visera Elite OTV-S190 Scope.
Olympus Visera Elite OTV-S190 Scope: Cystoscopic procedures will be performed using the Olympus Visera Elite OTV-S190 Scope
|
|---|---|---|
|
Overall Study
STARTED
|
30
|
30
|
|
Overall Study
COMPLETED
|
30
|
30
|
|
Overall Study
NOT COMPLETED
|
0
|
0
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Assessment of Infection Control, Practice Efficiency, and Health Economics of Sheathed Versus Standard Cystoscopy
Baseline characteristics by cohort
| Measure |
EndoSheath CST-5000 Scope
n=30 Participants
Cogentix Medical CST-5000 Flexible Video Cystoscope with Slide-On® EndoSheath® Technology. EndoSheath CST-5000 Scope.
EndoSheath CST-5000 Scope: Cystoscopic procedures will be performed using the EndoSheath CST-5000 Scope.
|
Olympus Visera Elite OTV-S190 Scope
n=30 Participants
Olympus HD Flexible Cysto-Nephro Videoscope (CYF-VH) with Olympus Visera Elite Platform, including OTV-S190 Video Processor CLV-S190 Xenon Light Source. Olympus Visera Elite OTV-S190 Scope.
Olympus Visera Elite OTV-S190 Scope: Cystoscopic procedures will be performed using the Olympus Visera Elite OTV-S190 Scope
|
Total
n=60 Participants
Total of all reporting groups
|
|---|---|---|---|
|
Age, Categorical
<=18 years
|
0 Participants
n=5 Participants
|
0 Participants
n=7 Participants
|
0 Participants
n=5 Participants
|
|
Age, Categorical
Between 18 and 65 years
|
25 Participants
n=5 Participants
|
27 Participants
n=7 Participants
|
52 Participants
n=5 Participants
|
|
Age, Categorical
>=65 years
|
5 Participants
n=5 Participants
|
3 Participants
n=7 Participants
|
8 Participants
n=5 Participants
|
|
Sex: Female, Male
Female
|
27 Participants
n=5 Participants
|
25 Participants
n=7 Participants
|
52 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
3 Participants
n=5 Participants
|
5 Participants
n=7 Participants
|
8 Participants
n=5 Participants
|
PRIMARY outcome
Timeframe: 10-14 Days Post ProcedureThe primary endpoint will be the change in bacteriuria pre- and post-procedure between EndoSheath CST-5000 cystoscope and standard (non-sheathed) Olympus Visera Elite OTV-S190 cystoscope during the course of routine clinical use in a urology clinic. The pre-procedure measurement of bacteriuria will occur on the day of the procedure. The post-procedure measurement of bacteriuria will occur approximately two weeks (10-14 days) post-procedure. This will be assessed by urine culture exams.
Outcome measures
| Measure |
EndoSheath CST-5000 Scope
n=30 Participants
Cogentix Medical CST-5000 Flexible Video Cystoscope with Slide-On® EndoSheath® Technology. EndoSheath CST-5000 Scope.
EndoSheath CST-5000 Scope: Cystoscopic procedures will be performed using the EndoSheath CST-5000 Scope.
|
Olympus Visera Elite OTV-S190 Scope
n=30 Participants
Olympus HD Flexible Cysto-Nephro Videoscope (CYF-VH) with Olympus Visera Elite Platform, including OTV-S190 Video Processor CLV-S190 Xenon Light Source. Olympus Visera Elite OTV-S190 Scope.
Olympus Visera Elite OTV-S190 Scope: Cystoscopic procedures will be performed using the Olympus Visera Elite OTV-S190 Scope
|
|---|---|---|
|
Number of Participants Who Had Post-Procedure Bacteriuria
|
0 Participants
|
1 Participants
|
SECONDARY outcome
Timeframe: Immediately after cystoscopy.Immediately after completion of each cystoscopy procedure, the bioburden on the cystoscopes will be evaluated. The flexible cystoscope sheath was removed for bioburden assessment. For each cystoscope, whether sheathed or standard, two locations were assessed - the control body and the shaft. Cultures were obtained wiping the entire surface with sterile saline pledgets. The sample pledgets were placed in 1 ml sterile saline and shaken for 30 seconds. Ten drops of 0.02 ml aliquots from the sample were spotted on two 5% blood agar plates and incubated at 35°C in CO2.
Outcome measures
| Measure |
EndoSheath CST-5000 Scope
n=30 cystoscope locations
Cogentix Medical CST-5000 Flexible Video Cystoscope with Slide-On® EndoSheath® Technology. EndoSheath CST-5000 Scope.
EndoSheath CST-5000 Scope: Cystoscopic procedures will be performed using the EndoSheath CST-5000 Scope.
|
Olympus Visera Elite OTV-S190 Scope
n=30 cystoscope locations
Olympus HD Flexible Cysto-Nephro Videoscope (CYF-VH) with Olympus Visera Elite Platform, including OTV-S190 Video Processor CLV-S190 Xenon Light Source. Olympus Visera Elite OTV-S190 Scope.
Olympus Visera Elite OTV-S190 Scope: Cystoscopic procedures will be performed using the Olympus Visera Elite OTV-S190 Scope
|
|---|---|---|
|
Number of Cystoscopes With Positive Bioburden Post-procedure.
Shaft
|
0 bioburdens
|
4 bioburdens
|
|
Number of Cystoscopes With Positive Bioburden Post-procedure.
Body
|
0 bioburdens
|
0 bioburdens
|
SECONDARY outcome
Timeframe: Beginning from the time a cystoscope is withdrawn from the urethral meatus at the end of a procedure until the completion of reprocessing, approximately 3,869 secondsThe total time required for a cystoscope to be reprocessed so that it is available for re-use in a subsequent procedure will be measured.
Outcome measures
| Measure |
EndoSheath CST-5000 Scope
n=30 Participants
Cogentix Medical CST-5000 Flexible Video Cystoscope with Slide-On® EndoSheath® Technology. EndoSheath CST-5000 Scope.
EndoSheath CST-5000 Scope: Cystoscopic procedures will be performed using the EndoSheath CST-5000 Scope.
|
Olympus Visera Elite OTV-S190 Scope
n=30 Participants
Olympus HD Flexible Cysto-Nephro Videoscope (CYF-VH) with Olympus Visera Elite Platform, including OTV-S190 Video Processor CLV-S190 Xenon Light Source. Olympus Visera Elite OTV-S190 Scope.
Olympus Visera Elite OTV-S190 Scope: Cystoscopic procedures will be performed using the Olympus Visera Elite OTV-S190 Scope
|
|---|---|---|
|
Total Time to Reprocess a Cystoscope
|
270.91 seconds
Standard Error 190
|
3838.78 seconds
Standard Error 1270
|
SECONDARY outcome
Timeframe: Approximately 2 min after the end of procedure.After undergoing cystoscopy, patients will be asked to complete Visual Analog Scales (VAS) instruments to determine their level of pain experienced during cystoscopy as well as their perception of discomfort with the procedure. The score range is 0 to 100. Higher scores denotes worse outcomes.
Outcome measures
| Measure |
EndoSheath CST-5000 Scope
n=30 Participants
Cogentix Medical CST-5000 Flexible Video Cystoscope with Slide-On® EndoSheath® Technology. EndoSheath CST-5000 Scope.
EndoSheath CST-5000 Scope: Cystoscopic procedures will be performed using the EndoSheath CST-5000 Scope.
|
Olympus Visera Elite OTV-S190 Scope
n=30 Participants
Olympus HD Flexible Cysto-Nephro Videoscope (CYF-VH) with Olympus Visera Elite Platform, including OTV-S190 Video Processor CLV-S190 Xenon Light Source. Olympus Visera Elite OTV-S190 Scope.
Olympus Visera Elite OTV-S190 Scope: Cystoscopic procedures will be performed using the Olympus Visera Elite OTV-S190 Scope
|
|---|---|---|
|
Subject Assessment of Procedure.
VAS Pain
|
29.3 units on a scale
Standard Error 23
|
26.5 units on a scale
Standard Error 20.77
|
|
Subject Assessment of Procedure.
VAS Discomfort
|
30.79 units on a scale
Standard Error 21.41
|
29.2 units on a scale
Standard Error 17.57
|
SECONDARY outcome
Timeframe: At the end of day of each procedure during 6 monthsAt the end of each day while the study is in progress, 6 members of the medical staff directly involved with the reprocessing of cystoscopes will evaluate the ease of reprocessing based on a 5-point Likert scale for the following parameters: ease of Insertion, ease of manipulation, optical quality, overall ease of use. The score range is 0 to 5. Higher score denotes better outcomes. A single value was derived per staff member and summarized for the group as a whole during 6 months.
Outcome measures
| Measure |
EndoSheath CST-5000 Scope
n=30 Participants
Cogentix Medical CST-5000 Flexible Video Cystoscope with Slide-On® EndoSheath® Technology. EndoSheath CST-5000 Scope.
EndoSheath CST-5000 Scope: Cystoscopic procedures will be performed using the EndoSheath CST-5000 Scope.
|
Olympus Visera Elite OTV-S190 Scope
n=30 Participants
Olympus HD Flexible Cysto-Nephro Videoscope (CYF-VH) with Olympus Visera Elite Platform, including OTV-S190 Video Processor CLV-S190 Xenon Light Source. Olympus Visera Elite OTV-S190 Scope.
Olympus Visera Elite OTV-S190 Scope: Cystoscopic procedures will be performed using the Olympus Visera Elite OTV-S190 Scope
|
|---|---|---|
|
Staff Assessment of Cystoscope Reprocessing.
Ease of Insertion
|
4.27 units on a scale
Standard Error 0.76
|
4.72 units on a scale
Standard Error 0.55
|
|
Staff Assessment of Cystoscope Reprocessing.
Ease of Manipulation
|
4.13 units on a scale
Standard Error 0.83
|
4.5 units on a scale
Standard Error 0.8
|
|
Staff Assessment of Cystoscope Reprocessing.
Optical Quality
|
3.9 units on a scale
Standard Error 1.15
|
4.3 units on a scale
Standard Error 1.12
|
|
Staff Assessment of Cystoscope Reprocessing.
Overall Ease of Use
|
4.02 units on a scale
Standard Error 0.93
|
4.45 units on a scale
Standard Error 0.85
|
SECONDARY outcome
Timeframe: 6 monthsThe health economics of reprocessing will be evaluated by associating personnel hourly costs with cystoscope reprocessing time segments. The total cost was averaged between pre-cleaning, cleaning, disinfection, rinsing, and drying for the 30 cystoscopes in each group for a duration of 6 months.
Outcome measures
| Measure |
EndoSheath CST-5000 Scope
n=30 Participants
Cogentix Medical CST-5000 Flexible Video Cystoscope with Slide-On® EndoSheath® Technology. EndoSheath CST-5000 Scope.
EndoSheath CST-5000 Scope: Cystoscopic procedures will be performed using the EndoSheath CST-5000 Scope.
|
Olympus Visera Elite OTV-S190 Scope
n=30 Participants
Olympus HD Flexible Cysto-Nephro Videoscope (CYF-VH) with Olympus Visera Elite Platform, including OTV-S190 Video Processor CLV-S190 Xenon Light Source. Olympus Visera Elite OTV-S190 Scope.
Olympus Visera Elite OTV-S190 Scope: Cystoscopic procedures will be performed using the Olympus Visera Elite OTV-S190 Scope
|
|---|---|---|
|
Total Cost of Cystoscopy Reprocessing
|
57,000.00 Dollars
|
32,000.00 Dollars
|
SECONDARY outcome
Timeframe: Per day.Number of procedures per day per scope. On a daily basis urology outpatient clinic performs an average of 5 cystoscopies.
Outcome measures
| Measure |
EndoSheath CST-5000 Scope
n=30 Participants
Cogentix Medical CST-5000 Flexible Video Cystoscope with Slide-On® EndoSheath® Technology. EndoSheath CST-5000 Scope.
EndoSheath CST-5000 Scope: Cystoscopic procedures will be performed using the EndoSheath CST-5000 Scope.
|
Olympus Visera Elite OTV-S190 Scope
n=30 Participants
Olympus HD Flexible Cysto-Nephro Videoscope (CYF-VH) with Olympus Visera Elite Platform, including OTV-S190 Video Processor CLV-S190 Xenon Light Source. Olympus Visera Elite OTV-S190 Scope.
Olympus Visera Elite OTV-S190 Scope: Cystoscopic procedures will be performed using the Olympus Visera Elite OTV-S190 Scope
|
|---|---|---|
|
Number of Procedures Per Day Per Scope.
|
5 Number of procedures per day per scope
Standard Deviation 2
|
5 Number of procedures per day per scope
Standard Deviation 2
|
Adverse Events
EndoSheath CST-5000 Scope
Olympus Visera Elite OTV-S190 Scope
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place