Effects of Low Intensity Therapeutic Ultrasound on Endothelial Function
NCT ID: NCT02872922
Last Updated: 2017-09-21
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
22 participants
INTERVENTIONAL
2016-12-10
2017-09-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
BASIC_SCIENCE
TRIPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Endothelial function after CWUT
Endothelial function of the all patients before and after application continuous waveform of ultrasound therapy (CWUT) measured by technique flow-mediated dilation (FMD).
Low intensity therapeutic ultrasound
The ultrasound equipment (Sonopulse III, 1 MHz, IBRAMED, Brazil) was calibrated with the radiation force method. In study, the head of the transducer will be positioned and applied for 5 min over the brachial artery at the same point that will be evaluated the endothelium function (Cruz et al., 2016). Continuous waveforms of ultrasound therapy (CWUT) are applied in the stationary mode for 5 minutes at a spatial averaged temporal intensity (SATA) of 0.4 W/cm2 using a transducer 1-MHz. A pulsed waveform of ultrasound therapy (PWUT) are applied (5 minutes) with a 20% duty cycle (2 ms on, 8 ms off), which represents a constant intensity of 0.08 W/cm2 SATA. In the placebo intervention, all of the procedures above are repeated, but with the ultrasound equipment powered off (Cruz et al., 2016).
Endothelial function after PWUT
Endothelial function of the all patients before and after application pulsed waveform of ultrasound therapy (PWUT) measured by technique flow-mediated dilation (FMD).
Low intensity therapeutic ultrasound
The ultrasound equipment (Sonopulse III, 1 MHz, IBRAMED, Brazil) was calibrated with the radiation force method. In study, the head of the transducer will be positioned and applied for 5 min over the brachial artery at the same point that will be evaluated the endothelium function (Cruz et al., 2016). Continuous waveforms of ultrasound therapy (CWUT) are applied in the stationary mode for 5 minutes at a spatial averaged temporal intensity (SATA) of 0.4 W/cm2 using a transducer 1-MHz. A pulsed waveform of ultrasound therapy (PWUT) are applied (5 minutes) with a 20% duty cycle (2 ms on, 8 ms off), which represents a constant intensity of 0.08 W/cm2 SATA. In the placebo intervention, all of the procedures above are repeated, but with the ultrasound equipment powered off (Cruz et al., 2016).
Endothelial function after PLACEBO
In the placebo intervention, all of the procedures above are repeated, but with the ultrasound equipment powered off. Endothelial function of the all patients before and after application placebo waveform of ultrasound therapy measured by technique flow-mediated dilation (FMD)
Low intensity therapeutic ultrasound
The ultrasound equipment (Sonopulse III, 1 MHz, IBRAMED, Brazil) was calibrated with the radiation force method. In study, the head of the transducer will be positioned and applied for 5 min over the brachial artery at the same point that will be evaluated the endothelium function (Cruz et al., 2016). Continuous waveforms of ultrasound therapy (CWUT) are applied in the stationary mode for 5 minutes at a spatial averaged temporal intensity (SATA) of 0.4 W/cm2 using a transducer 1-MHz. A pulsed waveform of ultrasound therapy (PWUT) are applied (5 minutes) with a 20% duty cycle (2 ms on, 8 ms off), which represents a constant intensity of 0.08 W/cm2 SATA. In the placebo intervention, all of the procedures above are repeated, but with the ultrasound equipment powered off (Cruz et al., 2016).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Low intensity therapeutic ultrasound
The ultrasound equipment (Sonopulse III, 1 MHz, IBRAMED, Brazil) was calibrated with the radiation force method. In study, the head of the transducer will be positioned and applied for 5 min over the brachial artery at the same point that will be evaluated the endothelium function (Cruz et al., 2016). Continuous waveforms of ultrasound therapy (CWUT) are applied in the stationary mode for 5 minutes at a spatial averaged temporal intensity (SATA) of 0.4 W/cm2 using a transducer 1-MHz. A pulsed waveform of ultrasound therapy (PWUT) are applied (5 minutes) with a 20% duty cycle (2 ms on, 8 ms off), which represents a constant intensity of 0.08 W/cm2 SATA. In the placebo intervention, all of the procedures above are repeated, but with the ultrasound equipment powered off (Cruz et al., 2016).
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age between 25 and 65 years old,
* Absence of morbid obesity,
* Non-smokers,
* With no symptoms of skeletal muscle disorders,
* No previous performing cardiovascular surgery,
* No previous diagnose of rheumatic, neurological, oncological, immune or hematologic diseases,
* Without evidence of psychiatric diseases and/or cognitive deficit.
Exclusion Criteria
* Leukocytosis, impaired fasting glycemia (\<70 and \>300 mg/dL) and
* Brachial artery diameter less than 2.5mm and larger than 5.0mm.
* On the day of the assessments have consumed of the alcoholic drink, caffeine and citrus juice
25 Years
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Universidade Federal de Santa Maria
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Luis Ulisses Signori
PhD
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Luis U Signori, PhD
Role: PRINCIPAL_INVESTIGATOR
Universidade Federal de Santa Maria
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Universidade Federal do Rio Grande
Rio Grande, Rio Grande do Sul, Brazil
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Corretti MC, Anderson TJ, Benjamin EJ, Celermajer D, Charbonneau F, Creager MA, Deanfield J, Drexler H, Gerhard-Herman M, Herrington D, Vallance P, Vita J, Vogel R; International Brachial Artery Reactivity Task Force. Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery: a report of the International Brachial Artery Reactivity Task Force. J Am Coll Cardiol. 2002 Jan 16;39(2):257-65. doi: 10.1016/s0735-1097(01)01746-6.
Poredos P, Jezovnik MK. Testing endothelial function and its clinical relevance. J Atheroscler Thromb. 2013;20(1):1-8. doi: 10.5551/jat.14340. Epub 2012 Sep 10.
Shechter M, Shechter A, Koren-Morag N, Feinberg MS, Hiersch L. Usefulness of brachial artery flow-mediated dilation to predict long-term cardiovascular events in subjects without heart disease. Am J Cardiol. 2014 Jan 1;113(1):162-7. doi: 10.1016/j.amjcard.2013.08.051. Epub 2013 Oct 5.
Thijssen DH, Black MA, Pyke KE, Padilla J, Atkinson G, Harris RA, Parker B, Widlansky ME, Tschakovsky ME, Green DJ. Assessment of flow-mediated dilation in humans: a methodological and physiological guideline. Am J Physiol Heart Circ Physiol. 2011 Jan;300(1):H2-12. doi: 10.1152/ajpheart.00471.2010. Epub 2010 Oct 15.
Xu Y, Arora RC, Hiebert BM, Lerner B, Szwajcer A, McDonald K, Rigatto C, Komenda P, Sood MM, Tangri N. Non-invasive endothelial function testing and the risk of adverse outcomes: a systematic review and meta-analysis. Eur Heart J Cardiovasc Imaging. 2014 Jul;15(7):736-46. doi: 10.1093/ehjci/jet256. Epub 2014 Jan 7.
Cruz JM, Hauck M, Cardoso Pereira AP, Moraes MB, Martins CN, da Silva Paulitsch F, Plentz RD, Peres W, Vargas da Silva AM, Signori LU. Effects of Different Therapeutic Ultrasound Waveforms on Endothelial Function in Healthy Volunteers: A Randomized Clinical Trial. Ultrasound Med Biol. 2016 Feb;42(2):471-80. doi: 10.1016/j.ultrasmedbio.2015.10.002. Epub 2015 Nov 12.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
UFSM1
Identifier Type: -
Identifier Source: org_study_id