Image-guided, Robotically Delivered Transcranial Magnetic Stimulation Treatment for Combat-Related Post-Traumatic Stress Disorder
NCT ID: NCT02853032
Last Updated: 2020-11-03
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
119 participants
INTERVENTIONAL
2017-07-05
2019-03-25
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
QUADRUPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Active rTMS to the right DLPFC
Active repetitive transcranial magnetic stimulation will be delivered to the right DLPFC using connectivity-based, image-guided aiming with the rTMS coil positioned using a robotic arm. In this arm, active rTMS will be delivered at 20 Hertz (Hz) in 2 sec trains with 14 sec inter-train intervals, 20 minutes/session (i.e. 1,600 pulses/session), 7 days/week for 20 consecutive days.
Active repetitive transcranial magnetic stimulation
The MagPro R30 is an advanced, high performance magnetic stimulator designed primarily for non-invasive clinical use. The non-invasive brain stimulation system will be used to deliver active repetitive electromagnetic pulses in this research study's treatment of post-traumatic stress disorder.
robotic arm
This robotic system is based on a commercially available neurosurgical robot. The robot is mounted on a mobile (i.e. retractable wheels) cart which holds the robot controller and the TMS power supply and pulse-generation computer. The robotic system will be used for TMS coil positioning/targeting.
Sham rTMS to the right DLPFC
Sham repetitive transcranial magnetic stimulation will be delivered to the right DLPFC using connectivity-based, image-guided aiming with the rTMS coil positioned using a robotic arm. In this arm, sham rTMS will be delivered at 20 Hz in 2 sec trains with 14 sec inter-train intervals, 20 minutes/session (i.e. 1,600 pulses/session), 7 days/week for 20 consecutive days.
robotic arm
This robotic system is based on a commercially available neurosurgical robot. The robot is mounted on a mobile (i.e. retractable wheels) cart which holds the robot controller and the TMS power supply and pulse-generation computer. The robotic system will be used for TMS coil positioning/targeting.
Sham repetitive transcranial magnetic stimulation
The MagPro R30 is an advanced, high performance magnetic stimulator designed primarily for non-invasive clinical use. The non-invasive brain stimulation system will be used to deliver placebo repetitive electromagnetic pulses in this research study's treatment of post-traumatic stress disorder.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Active repetitive transcranial magnetic stimulation
The MagPro R30 is an advanced, high performance magnetic stimulator designed primarily for non-invasive clinical use. The non-invasive brain stimulation system will be used to deliver active repetitive electromagnetic pulses in this research study's treatment of post-traumatic stress disorder.
robotic arm
This robotic system is based on a commercially available neurosurgical robot. The robot is mounted on a mobile (i.e. retractable wheels) cart which holds the robot controller and the TMS power supply and pulse-generation computer. The robotic system will be used for TMS coil positioning/targeting.
Sham repetitive transcranial magnetic stimulation
The MagPro R30 is an advanced, high performance magnetic stimulator designed primarily for non-invasive clinical use. The non-invasive brain stimulation system will be used to deliver placebo repetitive electromagnetic pulses in this research study's treatment of post-traumatic stress disorder.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Patients must have a diagnosis of PTSD confirmed by the Clinician-Administered PTSD Scale (CAPS-5) at screening,
3. Subjects must have a minimum PTSD Symptom Checklist (PCL-5) for DSM-V symptom severity rating of 25.
Exclusion Criteria
2. Substance use disorder during the 12 months prior to screening; except that Mild - Moderate, but not Severe, Alcohol Use Disorder (using DSM-5 criteria) will be allowed as determined by LRTC medical provider review.
3. Any history or signs of serious medical or neurological illness including seizure disorders. Except for seizures, a subject with a clinical abnormality may be included only if the study clinician considers the illness will not introduce additional risk and will not interfere with the study procedures. This will be determined during the screening phase via self-report and/or medical history review.
4. History of traumatic brain injury (TBI) with loss of consciousness for 20 minutes or more as determined by the History of Head Injuries questionnaire.
5. Females will be excluded if they are pregnant (i.e. positive pregnancy test identified after their LRTC intake).
6. Any history or signs of metal objects deemed unsafe for MRI or that may adversely affect image quality of the brain region (e.g. surgical clips, cardiac pacemakers, metal implants, etc.) in the body at the time of screening as indicated by self-report. MRI can have risks for persons with foreign bodies implanted in their body.
18 Years
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Laurel Ridge Treatment Center
OTHER
Consortium to Alleviate PTSD
OTHER
The University of Texas Health Science Center at San Antonio
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Felipe S. Salinas, Ph.D.
Assistant Professor--Research
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Felipe S Salinas, Ph.D.
Role: PRINCIPAL_INVESTIGATOR
The University of Texas Health Science Center at San Antonio
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Laurel Ridge Treatment Center
San Antonio, Texas, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Boggio PS, Rocha M, Oliveira MO, Fecteau S, Cohen RB, Campanha C, Ferreira-Santos E, Meleiro A, Corchs F, Zaghi S, Pascual-Leone A, Fregni F. Noninvasive brain stimulation with high-frequency and low-intensity repetitive transcranial magnetic stimulation treatment for posttraumatic stress disorder. J Clin Psychiatry. 2010 Aug;71(8):992-9. doi: 10.4088/JCP.08m04638blu. Epub 2009 Dec 29.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
HSC20160191H
Identifier Type: -
Identifier Source: org_study_id