Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE1
12 participants
INTERVENTIONAL
2016-04-30
2016-10-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
These improvements enhance survival and quality of life. In order to provide appropriate ventilation for each patient, the ventilator can generate different types of blowing:
* Continuous positive airway pressure (CPAP) which delivers a constant pressure to the mask
* Pressure support ventilation (PSV) which delivers a constant pressure to the mask and, on top of that, delivers more pressure when the patient begins to breathe in.
* Pressure control ventilation (PCV), which is similar to PSV, but use a fixed time to generate the flow when the patient begins to breathe in.
These different types of blowing have consequences on patient comfort as well as on the improvement of their ventilation.
To assess the improvement of the ventilation, the investigators currently use blood tests, however, these reflect overall output and may miss more subtle changes in breathing that could affect how patients feel.
Electrical impedance tomography (EIT) is a new technology that involves wearing a belt of sensors around the chest that provides information on how well the lungs are being filled with air by the ventilator. It allows a non-invasive assessment of the effect of NIV onto lung ventilation in real-time.
The investigators hope to use the EIT technology to assess in real-time patients lung ventilation when they are using the NIV. The investigators hope that EIT will provide them with information on which type of blowing is more effective and more comfortable than the others.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Electrical impedance tomography (EIT) is a new technology that involves wearing a belt of sensors around the chest that provides information on how well the lungs are being filled with air by the ventilator. It allows the assessment of these differences, which previously required the use of invasive equipment to obtain.
Optimising ventilator settings in the administration of non-invasive ventilation (NIV) can be improved with the addition of individual physiological data. This approach is limited due to the invasive techniques required to obtain this information, often leading to less ideal NIV settings promoting patient-ventilator asynchrony. It has been recently demonstrated by our group that all patients established on domiciliary NIV have a degree of patient-ventilator asynchrony and that the commonest type of asynchrony are triggering issues. Triggering asynchrony is promoted by mismatch between a patient's intrinsic positive end-expiratory pressure (iPEEP) and applied expiratory positive airway pressure (EPAP) with these ineffective efforts contributing to an increased work of breathing and patient discomfort. Previous strategies used to optimise patient triggering have involved the placement of oesophageal catheters in order to measure neural respiratory drive (NRD) to the diaphragm by electromyography (EMG) but again this process is invasive and often poorly tolerated. Electrical Impedance Tomography (EIT) is a non-invasive, bedside monitoring technique that provides semi-continuous, real-time information about the regional distribution of the changes in electrical resistivity of the lung tissue due to variations in ventilation in relation to a reference state.
Information is gained by repeatedly injecting small alternating electric currents (usually 5 mA) at high frequency of 50 - 80 kHz through a system of skin electrodes (usually 16) applied circumferentially around the thorax in a single plane between the 4th and 6th intercostal space. While an adjacent pair of electrodes 'injects' the current ('adjacent drive configuration'), all the remaining adjacent passive electrode pairs measure the differences in electric potential. A resistivity (impedance) image is reconstructed from this data by a mathematical algorithm using a two dimensional model and a simplified shape to represent the thoracic cross-section.
The resulting image possesses a high temporal and functional resolution making it possible to monitor dynamic physiological phenomena (e.g. delay in regional inflation or recruitment) on a breath by breath basis. It is important to realize that the EIT images are based on image reconstruction techniques that require at least one measurement on a well-defined reference state. All quantitative data are related to this reference and can only indirectly quantify (relative) changes in local lung impedance (but not absolute).
EIT can be used in mechanically ventilated patients to assess recruitment and to optimise ventilator settings to reduce risk of iatrogenic ventilator associated lung injury.
To date, EIT has only been validated in patient invasively ventilated or during self-ventilation.
The investigators hope to use the EIT technology to assess patients breathing using different ventilator modes in order to see if one is more effective and or more comfortable than the others. The investigators can use this information to help them set ventilators for future patients.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Treatment/Intervention
Each patient will be using Non Invasive Ventilation (NIV) and will use it on each possible ventilation mode in a random order with a 10 minutes washout period between modes.
NIV Group
Each patient will be using Non Invasive Ventilation (NIV) and will use it on each possible ventilation mode in a random order with a 10 minutes washout period between modes.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
NIV Group
Each patient will be using Non Invasive Ventilation (NIV) and will use it on each possible ventilation mode in a random order with a 10 minutes washout period between modes.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* FEV1/FVC \> 70%
Exclusion Criteria
* Aged \<18, \>80
* Significant physical or psychiatric comorbidity
* that would prevent compliance with trial protocol
18 Years
80 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
B&D Electromedical
INDUSTRY
Guy's and St Thomas' NHS Foundation Trust
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Nicholas Hart
Role: STUDY_CHAIR
GSTT
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Guys and St Thomas NHS Foundation
London, , United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
185543
Identifier Type: -
Identifier Source: org_study_id